SoliTek SOLID Series Solar Modules

Gebruiksinstruksies
- Read this guide entirely before installation.
- This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
- This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
- All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
- This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
- It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
- The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
- Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
- Versuim om instruksies in hierdie gids te volg, kan stelselkomponente beskadig, personeel in gevaar stel, eiendom beskadig of die paneelwaarborg ongeldig maak.
- Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.
ALGEMENE VEREISTES
- Lees asseblief hierdie gids volledig voor die installasie.
- Die doel van hierdie dokument is om minimum vereistes en aanbevelings vir veilige en suksesvolle installering van SoliTek PV-modules te verskaf.
- Hierdie dokument bevat ook vereistes wat nodig is om SoliTek PV-module voldoening aan IEC 61215, IEC 61730, UL 61730 standaarde te behou.
- Hierdie gids bevat basiese inligting rakende JSC “SoliTek Cells” SOLID reeks fotovoltaïese modules, hul installasie en veilige hantering. Alle instruksies moet gelees en verstaan word voordat u probeer installeer. Indien daar enige vrae is, kontak asseblief jou handelaar of JSC “SoliTek Cells” vir verdere inligting.
- This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
- It serves as a general but strictly mandatory reference for the Installer.
- Oortreding of onakkurate nakoming van enige klousule van hierdie dokumentasie maak die waarborg ongeldig.
- Die installeerder moet alle toepaslike plaaslike, staats- en federale regulasies en standaarde vir boukonstruksie, elektriese ontwerp, brand en veiligheid verstaan en volg, en moet met plaaslike owerhede nagaan om toepaslike permitvereistes te bepaal voordat hy probeer om FV-modules te installeer of in stand te hou en moet vertroud te raak met die meganiese en elektriese vereistes vir fotovoltaïese stelsels.
- Versuim om die instruksies in hierdie gids te volg, kan stelselkomponente beskadig, personeel in gevaar stel, eiendom beskadig of die paneelwaarborg ongeldig maak.
- Dak FV-stelsels moet slegs geïnstalleer word op wonings wat formeel ontleed is vir strukturele integriteit en bevestig is dat dit in staat is om die bykomende geweegde las van FV-stelselkomponente, insluitend FV-modules, deur 'n gesertifiseerde bouspesialis of ingenieur te hanteer.
- For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
- For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
- Die platplaat PV-module-konstruksie bestaan uit 'n gelamineerde samestelling van sonselle wat in 'n isolerende materiaal binne twee glasplate ingekapsuleer is.
- Bewaar hierdie dokumentasie op 'n veilige plek vir toekomstige verwysing.
- Moenie probeer om die module uitmekaar te haal nie, en moenie enige aangehegte naamborde of komponente verwyder nie! Deur dit te doen, sal die waarborg ongeldig wees.
Hantering & Toepassing
HANTERING
- SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
- Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
- Moenie die maksimum hoogte van palette wat gestapel moet word oorskry nie, soos aangedui op die paletteverpakking.
- Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
- SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
- Do not exert mechanical stress on the cables.
- Never step on PV modules or drop or place heavy objects on them.
- Be careful when placing PV modules on hard surfaces and secure them from falling.
- Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
- Broken or damaged PV modules must be handled carefully and disposed of properly.
AANSOEK
Beperkings
- SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
- PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
- Do not install modules above 2000 m (6561 ft) altitude above sea level
- Kunsmatig gekonsentreerde lig moet nie op SoliTek PV-modules gerig word nie.
Aanbevelings
- SoliTek beveel aan dat FV-modules teen 'n minimum kantelhoek van 10 grade gemonteer word om behoorlike selfreiniging van reën moontlik te maak.
- Gedeeltelike of volledige skadu van 'n FV-module of -modules kan stelselwerkverrigting aansienlik verminder.
- SoliTek beveel aan om die hoeveelheid skadu deur die jaar te verminder om die hoeveelheid energie wat deur die FV-modules geproduseer word, te verhoog.
- Hoë sisteem voltages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
- The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage oplewing.
- Beter moduleventilasie en korter verbindingskabels verhoog die produksie van elektriese energie.
Vir bifaciale modules:
- Dit word aanbeveel om die PV-paneelhoogte vanaf die grond te verhoog sodat meer lig onder die module kan beweeg en dan weerkaats
- Die tweevlakwins neem aansienlik toe as modules bo wit (hoë albedowaarde), ligreflekterende oppervlaktes geïnstalleer word.
Elektriese installasie
VEILIGHEID
- PV-modules kan stroom en voltage wanneer dit aan lig van enige intensiteit blootgestel word. Elektriese stroom neem toe met hoër ligintensiteit. DC voltage van 50 Volt of hoër is potensieel dodelik. Kontak die lewendige stroombane van 'n FV-stelsel wat onder lig werk, kan dodelike elektriese skok tot gevolg hê.
- Ontspan PV-modules deur hulle heeltemal van lig te verwyder of deur hul vooroppervlak met 'n ondeursigtige materiaal te bedek. Met betrekking tot die veiligheidsregulasies vir lewendige elektriese toerusting wanneer daar met modules gewerk word wat aan enige lig blootgestel word. Gebruik geïsoleerde gereedskap en moenie metaaljuweliersware dra terwyl jy met PV-modules werk nie.
- Om boogvorming en elektriese skok te vermy, moenie elektriese verbindings onder las ontkoppel nie. Foutiewe verbindings kan ook lei tot boogvorming en elektriese skok. Hou verbindings droog en skoon en maak seker dat hulle in behoorlike werkende toestand is. Moet nooit metaalvoorwerpe in die verbindings plaas of dit op enige manier verander om 'n elektriese verbinding te verseker nie.
- Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
- The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
- Die installering van fotovoltaïese sonkragstelsels vereis gespesialiseerde vaardighede en kennis. Dit moet slegs deur gekwalifiseerde en spesiaal opgeleide personeel uitgevoer word. Die installeerder aanvaar alle risiko van besering, insluitend die risiko van elektriese skok.
- Gebruik slegs toerusting, verbindings, bedrading en monteer hardeware wat spesifiek ontwerp is vir gebruik in 'n fotovoltaïese stelsel.
- Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
- Wanneer drade ontkoppel wat gekoppel is aan 'n fotovoltaïese module wat aan lig blootgestel word, kan 'n elektriese boog voorkom. Boë kan brandwonde veroorsaak, brande veroorsaak of andersins veiligheidsprobleme (tot dodelike elektriese skok) veroorsaak.
- Kyk vir oorblywende voltage before starting and observe the local safety-relevant regulations for such working conditions.
- Onder normale toestande kan 'n fotovoltaïese module meer stroom en/of voltage (hier: 30V DC) as wat by standaardtoetstoestande aangemeld is.
- Kontak met 'n DC voltage van 30 V of meer is potensieel gevaarlik. Wees versigtig wanneer jy modules wat aan sonlig blootgestel word, bedra of hanteer.
- Koppel slegs modules met dieselfde gegradeerde uitsetstroom in serie. Indien modules in serie verbind word, sal die totale voltage is gelyk aan die som van die individuele module voltages.
- Verbind slegs modules of reekskombinasies van modules met dieselfde voltage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
- Gebruik altyd dieselfde tipe module binne 'n bepaalde fotovoltaïese stelsel.
- If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
- Gebruik toepaslike veiligheidstoerusting (geïsoleerde gereedskap, diëlektriese handskoene, skoene en ens.) wat goedgekeur is vir gebruik op elektriese installasies.
KONFIGURASIE
- Onder normale toestande sal 'n fotovoltaïese module waarskynlik toestande ervaar wat meer stroom en/of voltage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) moet vermenigvuldig word met 'n faktor van tot 1.25 gebaseer op die laagste en hoogste omgewingstemperatuur wat aangeteken is vir die installasie plek wanneer komponent vol bepaal wordtage graderings, geleier stroom graderings, lont groottes, en grootte van kontroles gekoppel aan die PV uitset.
- Voltage is additief wanneer FV-modules direk in serie gekoppel word, en modulestrome is additief wanneer FV-modules direk in parallel gekoppel word. FV-modules met verskillende elektriese eienskappe moet nie direk in serie gekoppel word nie. Die gebruik van geskikte derdeparty-elektroniese toestelle wat aan FV-modules gekoppel is, kan verskillende elektriese verbindings moontlik maak en moet volgens die vervaardiger se gespesifiseerde instruksies geïnstalleer word.
- Die maksimum voltage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Ook die maksimum inset voltage van die omskakelaar en van die ander elektriese toestelle in die stelsel moet in ag geneem word. Die oopkring voltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
- Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.
OORSTROOMBESKERMINGSTOESTEL (OCPD)
- When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
- An overcurrent protection device is required for each series string if more than two series are connected in parallel.
- In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
- The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
- Versmelt amp gradering ≥ 1.25 x Isk
- Kies die volgende hoër standaardgradering by die katalogus van beskikbare PV Sekerings.
- ISC = Kortsluitstroom van een module by Standaardtoetstoestande (STC).
- Met inagneming van die waardes van ISC van SoliTek-modules, is die regte waarde van die PV Sekerings wat by die installasie gebruik moet word 30 A. SoliTek beveel aan om PV smeltings in beide die positiewe en negatiewe geleiers te gebruik.
KABEL EN BEDRADING
SoliTek PV-modules word voorsien van twee standaard, sonligbestande uitsetkabels wat afgesluit is met PV-verbindings wat gereed is vir die meeste installasies. Die positiewe (+) aansluiting het 'n manlike aansluiting terwyl die negatiewe (-) aansluiting 'n vroulike aansluiting het. Die modulebedrading is bedoel vir serieverbindings (dws manlike (+) na vroulike (-) verbindings), maar kan ook gebruik word om geskikte derdeparty elektriese toestelle wat alternatiewe bedradingkonfigurasies kan hê, te koppel solank die vervaardiger se instruksies gevolg word.
Gebruik veldbedrading met geskikte deursnee-areas wat goedgekeur is vir gebruik by die maksimum kortsluitstroom van die FV-module. Alle bedrading moet dubbel-geïsoleerde, kruisgekoppelde kabels wees met 'n minimum aanslag van 1,8 kV (meer as 1500 V vol.tage) en 'n minimum gegradeerde temperatuur van 90 ˚C (190 °F). Draadgrootte nie minder nie as 4 mm² (12 AWG). Die isolasietipe moet gepas wees vir die tipe installasiemetode wat gebruik word en moet aan IEC 61730 en Veiligheidsklas II-vereistes voldoen.
- Isolasievlak: 1,8 kV (geleier-geleier).
- Temperatuur: -40 °C tot +90 °C (-40 °F tot 190 °F) ten minste.
- Konstruksie van geleier: vertinde gestrengelde koperdraad met kopersuiwerheid groter as 99,9%.
- Primêre isolasie: kruisgekoppelde poliëtileen (XLPE), sonlig- en vogbestand, vlamvertrager. Geskik vir buise en renbane wat ondergronds geïnstalleer is.
- Isolasie (baadjie): termoplasties, sonligbestand, vlamvertragend, waterbestand.
- Minimum kabel buite deursnee met isolasie – 5,2 mm (2,05 duim).
- Minimum geleier deursnee – 4 mm² (12 AWG).
SoliTek beveel aan dat installeerders slegs sonligbestande kabels gebruik wat vir gelykstroom (DC) bedrading in PV-stelsels gekwalifiseer is. Kabels moet op so 'n manier aan die monteerstruktuur vasgemaak word dat meganiese skade aan die kabel en/of die module vermy word. Moenie spanning op die kabels uitoefen nie. Vir bevestiging, gebruik gepaste middele, soos sonligbestande kabelbinders en/of draadbestuursklems. Terwyl die kabels sonligbestand en waterdig is, vermy waar moontlik direkte sonligblootstelling en wateronderdompeling van die kabels.
Standaard lengte van kabels vanaf die aansluitkaste is 1,2 m (47,24 duim). Daar word beoog dat twee panele in die stelsel met mekaar sal verbind.
grou
- Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:
Framed type modules grounding
Gate gemerk met 'n aardingsmerk op die raam kan slegs vir aarding gebruik word. Moenie bykomende grondgate op die moduleraam boor nie.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Die aardgeleier moet dan met 'n geskikte aardelektrode 'n verbinding met aarde maak.
A bolted connection is required; it incorporates:
- 'n Boutgrootte van M4.
- 'n Tandwasser onder die boutkop of 'n getande bout moet nie-geleidende bedekkings soos geanodiseerde raam binnedring.
- 'n Maak moer wat geskik is vir M4 bout.
- Alle hardeware moet van nie-ysterhoudende metaal, 300-reeks vlekvrye staal, of gepaste korrosiebeskerm wees.
- Die aanbevole wringkrag om die moer te sluit is 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
- Aardbout moet deur al die verbindingselemente gaan.

- Toestelle wat gelys en geïdentifiseer is vir die aarding van metaalrame van FV-modules word toegelaat om die blootgestelde metaalrame van die module aan gegronde monteerstrukture te aard.
- In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
- Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
- Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.
Frameless type modules grounding
- Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.
SKAKELAARS
- Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
- Moenie probeer om 'n elektriese verbinding met nat, vuil of andersins foutiewe verbindings te maak nie.
- Vermy blootstelling aan sonlig en water onderdompeling van die verbindings. Vermy verbindings wat op die grond of dakoppervlak rus.
- Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
- Kontroleer dat alle elektriese verbindings stewig vasgemaak is. Maak seker dat alle sluitverbindings ten volle ingeskakel en gesluit is.
VERBLYP DIODES
The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Bypass-diodes is nie oorstroombeskermingstoestelle nie. Omleidingdiodes lei stroom van die selstringe af in die geval van gedeeltelike skaduwee. Die kenmerke van hierdie diodes:
- Voltage-gradering – 50 V.
- Huidige gradering – 25 A.
BRANDKLAS-GRADERING
- SoliTek SOLID Bifacial- en Blackstar-modules is deur die IEC-brandtoets goedgekeur en het Vlambaarheidsklas A behaal. Brandtoets is uitgevoer teen die helling van 127 mm (5 duim) per 300 mm (11,81 duim), soos voorgeskryf in punt A.2.5 van IEC 61730-2.
- SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.
Meganiese montering
- The mechanical loads described in this manual are the test loads.
- For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.
ALGEMENE VEREISTES
- Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
- Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
- If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
- Let asseblief op die veiligheidsregulasies en installasie-instruksies wat by die monteerstelsel ingesluit is. Indien nodig, kontak asseblief die verskaffer direk vir verdere inligting.
- The modules must be safely set onto the mounting rail.
- The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
- The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
- Before installing modules on a roof, ensure that the roof construction is suitable.
- In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
- Maak seker dat die monteerreling nie die modules sal vervorm of beïnvloed wanneer dit uitsit as gevolg van termiese uitsetting nie.
- The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
- Moenie probeer om gate in die glasoppervlak en die rame van die modules te boor nie, aangesien dit die waarborg ongeldig maak.
- The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.
Die monteerkomponente moet van duursame, korrosiewe en UV-bestande materiale gemaak word (vlekvrye staal en geanodiseerde aluminiumkomponente word aanbeveel).
MONTAGE MET CLAMPS
- Gebruik ten minste 4 laminaat clamps om modules op die monteerrelings vas te maak. Modules clampse metaaldele moet nie met die voor- of agterglas in aanraking kom nie. By die keuse van hierdie tipe clamp-monteermetode, gebruik ten minste vier clamps op elke module; twee clamps moet aan elke lang kant geheg word. Afhangende van plaaslike wind- en sneeuvragte, addisionele klamps kan vereis word om te verseker dat modules die las kan dra.
- Clampse draaimoment moet minstens 15 Nm (11,06 vt-lb) wees, maar nie groter as 20 Nm (14,75 vt-lb) nie. Gewoonlik word 15 Nm (11,06 ft-lb) bereik wanneer twee aluminium profiles aan mekaar raak. Wanneer 'n module in portretoriëntasie geïnstalleer word op die hellende dak wat 'n helling van >45° het, word addisionele haak aan die onderkant van die module benodig.

SOLID Black, Semi-clear, Satin, Agro Frameless
Met dwarsrelings


BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting
- By die keuse van hierdie tipe clamp-monteermetode, gebruik ten minste vier clamps op elke module; twee clamps moet aan elke kant van die module geheg word. Modules clamps moet nie met die voorste glas in aanraking kom nie en moet nie die raam vervorm nie.
- Maak seker dat jy skadu-effekte op die sonselle van die module cl vermyamps.
- The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
- Die lengte van clamp should be at least 30 mm (1,18 inch).
- Die klamp moet die moduleraam met ten minste 5 mm (0,2 duim), maar nie meer as 10 mm (0,4 duim) oorvleuel nie.
Met dwarsrelings

Sonder dwarsrelings of relings is loodreg op die lang syraam

Met invoegstelsel

Montage met boute
- Die module moet vasgemaak en ondersteun word deur vier M8 vlekvrye staal boute deur die aangeduide monteringsgate op die dwarsstawe. Wringkrag op die clamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
- If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clamphardeware moet gekies word.

- Mounting with bolts can be done only through dedicated predrilled holes in the frame.
- Die boor van nuwe gate is verbode en sal die waarborg ongeldig maak.

POSISIE VAN DIE VERBINDINGSKOS
- Vir die afstand tussen aansluitboks en rand van die module of ander afmetings van aansluitboksposisie en -areas, verwys asseblief na die figure hieronder.

ONDERHOUD
- Om optimale moduleprestasie te verseker, beveel SoliTek die volgende aan:
- Indien nodig, kan die glasfront van die module skoongemaak word met water en 'n sagte spons of lap.
- ’n Sagte, nie-skuur skoonmaakmiddel kan gebruik word om meer hardnekkige vlekke te verwyder.
- Gaan die elektriese en meganiese verbindings gereeld na en maak seker dat hulle skoon, veilig, volledig en veilig is.
- In die geval van 'n probleem, raadpleeg 'n gelisensieerde/gekwalifiseerde persoon.
SPESIFIKASIES
| Parameter \ Model | SWARTSTER B.96 | SOLID Black (Semi-Clear) B.96 35(40) mm | SWARTSTER Satin B.96 | MAGNUS B.108 |
| Toets toestande | SBM | SBM | SBM | SBM |
| Nominale krag | 455 W | 455 W | 445 W | 510 W |
| Elektriese data @STC | ||||
| Maksimum drywing (Pmax), W | 455 | 455 | 445 | 510 |
| Voltage by Maksimum Krag (Vmpp), V | 29,71 | 29,71 | 29,40 | 33,34 |
| Stroom by maksimum krag (Impp), A | 15,31 | 15,31 | 15,14 | 15,30 |
| Oopkring Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 39,06 |
| Kortsluitstroom (Isc), A | 15,97 | 15,97 | 15,79 | 15,95 |
| Termiese data | ||||
| Bedryfstemperatuurreeks | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Temperatuurkoëffisiënt van Pmax | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) |
| Temperatuurkoëffisiënt van Voc | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) |
| Temperatuurkoëffisiënt van Isk | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,036% /° C (°F) |
| Grootte en gewig data | ||||
| Lengte | 1762 mm | 1762 mm | 1762 mm | 1961 mm |
| Breedte | 1134 mm | 1134 mm | 1134 mm | 1134 mm |
| Dikte | 30 mm | 35(40) mm | 30 mm | 30 mm |
| Gewig | 25,5 kg | 35 (36) kg | 25,5 kg | 28,5 kg |
| Montage metode | ||||
| Reference to the chapter | 3.3 | 3.3 | 3.3 | 3.3 |
| Ander | ||||
| Maksimum omgekeerde stroom, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/tipe II | |||
| Maksimum stelsel voltage, v | 1500 | |||
Table 9. Electrical and mechanical parameters table.
| Parameter \ Model | SOLIED Semi- clear B.96 | SOLID Black B.96 | SOLIED Satin B.96 | SOLIED Agro B.64 |
| Toets toestande | SBM | SBM | SBM | SBM |
| Nominale krag | 455 W | 455 W | 445 W | 300 W |
| Elektriese data @STC | ||||
| Maksimum drywing (Pmax), W | 455 | 455 | 445 | 300 |
| Voltage by Maksimum Krag (Vmpp), V | 29,71 | 29,71 | 29,40 | 19,60 |
| Stroom by maksimum krag (Impp), A | 15,31 | 15,31 | 15,14 | 15,31 |
| Oopkring Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 22,76 |
| Kortsluitstroom (Isc), A | 15,97 | 15,97 | 15,79 | 15,97 |
| Termiese data | ||||
| Bedryfstemperatuurreeks | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Temperatuurkoëffisiënt van Pmax | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Temperatuurkoëffisiënt van Voc | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Temperatuurkoëffisiënt van Isk | +0,045% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) |
| Grootte en gewig data | ||||
| Lengte | 1772 ± 2 mm | 1772 ± 2 mm | 1772 ± 2 mm | 1772 ± 2 mm |
| Breedte | 1144±2 | 1144±2 | 1144 ± 2 mm | 1144 ± 2 mm |
| Dikte | 7,2 mm | 7,2 mm | 7,2 mm | 7,2 mm |
| Gewig | 33 kg | 33 kg | 33 kg | 33 kg |
| Montage metode | ||||
| Reference to the chapter | 3.2 | 3.2 | 3.2 | 3.2 |
| Ander | ||||
| Maksimum omgekeerde stroom, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/tipe II | |||
| Maksimum stelsel voltage, v | 1500 | |||
Table 10. Electrical and mechanical parameters table.
| Parameter \ Model | SOLID Satin B.96 35 mm | SOLID Satin B. 96 40 mm | SOLID AgroB.64 35 mm | SOLID AgroB.64 40 mm |
| Toets toestande | SBM | SBM | SBM | SBM |
| Nominale krag | 445 W | 445 W | 300 W | 300 W |
| Elektriese data @STC | ||||
| Maksimum drywing (Pmax), W | 445 | 445 | 300 | 300 |
| Voltage by Maksimum Krag (Vmpp), V | 29,40 | 29,40 | 19,60 | 19,60 |
| Stroom by maksimum krag (Impp), A | 15,14 | 15,14 | 15,31 | 15,31 |
| Oopkring Voltage (Voc), V | 34,40 | 34,40 | 22,78 | 22,78 |
| Kortsluitstroom (Isc), A | 15,79 | 15,79 | 15,97 | 15,97 |
| Termiese data | ||||
| Bedryfstemperatuurreeks | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Temperatuurkoëffisiënt van Pmax | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Temperatuurkoëffisiënt van Voc | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Temperatuurkoëffisiënt van Isk | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) |
| Grootte en gewig data | ||||
| Lengte | 1762 mm | 1762 mm | 1762 mm | 1762 mm |
| Breedte | 1134 mm | 1134 mm | 1134 mm | 1134 mm |
| Dikte | 35 mm | 40 mm | 35 mm | 40 mm |
| Gewig | 35 kg | 36 kg | 35 kg | 36 kg |
| Montage metode | ||||
| Reference to the chapter | 3.3 | |||
| Ander | ||||
| Maksimum omgekeerde stroom, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/tipe II | |||
| Maksimum stelsel voltage, v | 1500 | |||
Table 11.Electrical and mechanical parameters table.
- The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
- Alle SoliTek SOLID PV-panele stem ooreen met elektriese veiligheidsklas II.
Vrywaring van aanspreeklikheid
- Aangesien dit onmoontlik is vir SoliTek om installasie, werking, toepassing en instandhouding van die fotovoltaïese stelsel volgens hierdie instruksie te beheer. SoliTek aanvaar nie verantwoordelikheid nie en ontken uitdruklik aanspreeklikheid vir enige verlies, skade of uitgawe wat voortspruit uit of op enige manier verband hou met sodanige installasie, bedryf, gebruik of instandhouding.
- SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
- The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.
Gereelde vrae
- Q: What should I do before installing the PV modules?
- A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
- Q: Can I install the PV modules myself without professional training?
- A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
- Q: What happens if I don’t follow the instructions in this guide?
- A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
- Q: Is it safe to work on a rooftop during installation?
- A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
- Q: How should I store the PV modules before installation?
- A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.
Dokumente / Hulpbronne
![]() | SOLID Series Solar Modules |
Verwysings
- solitek.euwww.solitek.eu
- Gebruikershandleidingmanual.tools