With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guarantee for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.

Veiligheidsinstruksies

  • Die toestel mag slegs gebruik word vir die beoogde doel wat deur die vervaardiger ontwerp is.
  • Die gebruikshandleiding moet te alle tye gerieflik vir elke gebruiker beskikbaar gehou word.
  • Ongemagtigde veranderinge en die gebruik van onderdele en bykomende toestelle wat nie deur die vervaardiger verkoop of aanbeveel is nie, kan brand, elektriese skokke of beserings veroorsaak. Sulke ongemagtigde maatreëls sal enige aanspreeklikheid deur die vervaardiger uitsluit.
  • Die aanspreeklikheidsvoorskrifte van die vervaardiger in die uitgawe wat ten tyde van aankoop geldig was, is geldig vir die toestel. Die vervaardiger sal nie wetlik verantwoordelik gehou word vir onakkuraathede, foute of weglatings in die handleiding of outomatiese stel parameters vir 'n toestel of vir 'n verkeerde toepassing van 'n toestel nie.
  • Herstelwerk mag slegs deur die vervaardiger uitgevoer word.
  • Installation, operation, and maintenance procedures have to be carried out by professional and qualified personnel.
  • Gebruik van die toestel en sy installasie moet in ooreenstemming met nasionale wetlike vereistes en plaaslike elektriese kodes wees.
  • Wanneer daar aan toestelle gewerk word, moet die geldige veiligheidsregulasies nagekom word.
  • Voordat u aan die toestel raak, moet die kragtoevoer altyd onderbreek word. Maak seker dat die toestel sonder voltage deur te meet. Die vervaag van 'n operasiebeheer (LED) is geen aanduiding vir 'n onderbreek kragtoevoer of die toestel wat nie vol is nietage!

LET WEL:

  • Wearers of pacemakers
    • Although this device does not exceed the permissible limits for electromagnetic fields, you should keep a minimum distance of 25 cm between the device and your pacemaker and not stay in the immediate vicinity of the device or the antenna for long periods of time.

History of documentation

Hersiening Data Beskrywing
0e Augustus 2025 Aanvanklike weergawe
1e Oktober 2025 Foutoplossing

Supported documents

Nee. Supported documents Doc.No.
[1] Verdere inligting https://www.feig.de/en/login/  
[2] Handleiding H50420-xe-ID-B
[3] Quick Start PR(M)103-USB M50630-xde-ID-B
[4] Quick Start MR(M)103-A M50628-xde-ID-B
[5] Quick Start MR103-E M50629-xde-ID-B
[6] Quick Start MR(M)103-USBC M50627-xde-ID-B

Verduideliking van simbole

Simbool Verduideliking
VDC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2) Direkte voltage simbool

Prestasiekenmerk

Algemene inligting

  • All reader variants described here have been developed for contactless data exchange with transponders whose operating frequency is 13.56 MHz.
  • The ID PR103 has an integrated antenna and works with a transponder-dependent, typical reading range of 20 cm. The reader is equipped with a USB interface for communication with the host.
  • The ID MR103 variants are equipped with a connection for an external antenna and work with a transponder-dependent, typical reading range of 40 cm.
  • The following interfaces are available for communication with the host: RS232, USB, USBC, Ethernet.
  • The “Anticollision” function enables the simultaneous reading of up to 100 x ISO15693 or 20 x I-CODE1 transponders.
  • The reader variants are available as a housing version and as a module version.

Reader type code

Soort leser Weergawe Koppelvlak
79 (Hex.: 0x4F) A RS232
USB USB 2.0
USBC USBC
E (Ethernet) LAN

Oortjie 1: Soort leser

verbyview

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (3)

Reader versions

Leser Type Firmware Weergawe Koppelvlak
ID MR103-USB Standaard Behuising USB
ID MRM103-USB Standaard Module USB
ID MR103-USBC Standaard Behuising USBC
ID MR103-A Standaard Behuising RS232
ID MRM103-A Standaard Module RS232
ID MR103-E Ethernet Behuising LAN
ID PR103-USB Standaard Behuising USB
ID PRM103-USB Standaard Module USB

Oortjie 2: Reader version

Ondersteunde bedryfsmodusse

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (4)

Oortjie 3: Bedryfsmodus

Omvang van aflewering

  • 1 x Toestel
  • 1 x Quick Start document

Kubersekuriteit

Cyber Security (MR103-E)
Ingebruikneming van die toestel

BELANGRIKE KENNISGEWING In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), the following points must be taken into account for the product ID MR103-E:

  • When using the network interface (Ethernet), it may be necessary to create at least one user to enable various functions such as changing the configuration. The user and the password MUST be set by the person who puts the device into operation on first use before it is logically connected to a network or by an authorized entity within a network where access is limited to authorized entities.
  • When security and/or network assets (keys, certificates, ethernet configuration parameters) are transferred via network interface (Ethernet) TLS encryption must be used to secure the communication.

Cyber Security related Firmware Updates

BELANGRIKE KENNISGEWING: In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), you are required to register in the FEIG download area under https://www.feig.de/en/ and subscribe to notifications for cybersecurity-related firmware and software updates for the product ID MR103-E.

Firmware downgrade

BELANGRIKE KENNISGEWING: A firmware downgrade to older major release versions is not possible in order to prevent old major versions with known cyber security vulnerabilities from being executed on the device.

Installasie

Housing version

  • The readers are designed for indoor applications.
  • Wall and under-counter mounting are possible with the optionally available mounting kit.

Sien 8.1 Wall mounting or under-counter mounting

Afmetings

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (5)

Modul version
The Module version is intended for installation in customer housings.

Modul dimension [mm]

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (6)

Koppelvlak oorview en verbindings

Depending on the reader variant, different connections and interfaces are available.

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (7)

Interface designation

Koppelaar Beskrywing
X1 Power supply 12 – 24V DC/       ± 10%
X2 RS232 & Power supply 12 – 24V DC/        ± 10%
X3 USB / USBC
X4 10/100Tbase Network interface (RJ45) LAN
MIER 1 Connector ext. antenna (Impedance Ω)

Oortjie 4: Connector beskrywing

Antenna connection ANT1

There is an SMA socket on the circuit board or on the housing for connecting the external antenna.

LET WEL:

  • The antenna must be adjusted to the value 50 Ω (50 Ω L 15°).
  • The optimum operating quality of the antenna should be in the range QB = 10…20. To determine the operating quality, the antenna must be supplied with a 50 Ω source, e.g. a network analyzer or a frequency generator.
  • When connecting an antenna, make sure that it does not exceed the permissible limit values of the national regulations regarding radio equipment.
  • The maximum tightening torque of the SMA sockets is 0.45 Nm.

DC Voltage on antenna connector ANT1

'N GS voltage can be applied from the reader to the ANT1 antenna connection. This DC voltage can be used to supply an LED, for example.

LET WEL:

  • Die DC voltage is only designed for low currents. The DC voltage (6,9 V± 1 V) can be loaded up to a maximum of 5mA.
  • Only antennas that are suitable for DC voltage and do not short-circuit the DC voltage may be connected.
  • When connecting other devices (e.g. VSWR meters), make sure that they are also suitable for DC voltage.
  • Hierdie DC voltage is not suitable for supplying the automatic antenna tuner ID ISC.DAT.

verbyview Kragtoevoer

ID PR(M)103-USB X3 5 VDC / 500 mA (via USB)
ID MR(M)103-A X2 Speld 1 = GND

Pin 2 = RxD Pin 3 = TxD Pin 4 = GND

Pin 5 = 12 bis 24V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2)

ID MR103-E X1 External Power Supply Unit (12 bis 24V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2))*
ID MR(M)103-USB X1 External Power Supply Unit (12 bis 24V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2))*
ID MR103-USBC X3 5V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2)/ 1,5A (via USBC)

Oortjie 5: Kragtoevoer

X1: External Power Supply*

  • The device may only be supplied by a power source in accordance with EN 62368-1 Chapter Q.1 Power sources of limited power or with a power supply unit certified in accordance with NEC Class 2/LPS.
  • For more information on available power supply units, see Accessories.

Connector for external Power Supply Unit

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (8)X2: RS232 Interface (ID MR103-A)
The transmission parameters can be configured via software protocol.

Connector X2 / Pin Assignment

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (9)X3: USB-Interface (ID PR103-USB / ID MR103-USB, USBC)
The USB interface is connected via socket X3 (ID PR103-USB / ID MR103-USB / -USBC). The assignment is standardized. The data rate of the reader is limited to 12 Mbit (USB Full Speed). A standard USBC cable can be used.

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (10) LET WEL: Maximum length of the USB cab e: ≤ 3 m

X4: Ethernet-Interface (ID MR103-E)

  • The reader has an integrated 10/100 base-T network interface with standard RJ-45 connection. The connection is made via X4 and has automatic crossover detection in accordance with the 1000BASE-T standard.
  • For structured cabling, at least CAT5 category cables should be used. This guarantees problem-free operation at 10 Mbps or 100 Mbps.
  • A prerequisite for using the TCP/IP protocol is that each device on the network has its own IP address. All readers have a factory-set IP address.
  • The transmission parameters can be configured via software protocol.
Netwerk Adres
IP adres 192.168.10.10
Subnet masker 255.255.255.0
Port 10001
DHCP ON

Oortjie 8: Default setting Ethernet Interface

LET WEL:

  • The reader has a DHCP-capable TCP/IP interface.
  • A shielded STP (shielded and twisted pair) CAT5 cable must be used.

Bedryfs- en vertoonelemente

Default settings for LED indication

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (11)

Radio Goedkeurings

Verklaring van ooreenstemming (CE)

  • CE-verklaring van ooreenstemming
    • Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID PRM103 / ID MRM103 is in compliance with Directive 2014/53/EU.
    • Die volledige teks van die EU-verklaring van ooreenstemming is beskikbaar by die volgende internetadres: https://www.feig.de/en/service/.

VSA (FCC) en Kanada (IC)

LET WEL: The RFID reader ID PR103 / MR103 contains the RFID module ID PRM103 / MRM103.

Produk naam: ID PR103 / MR103
FCC ID: IC: PJMPRM103 PJMMRM103 6633A-PRM103 6633A-MRM103
Kennisgewing vir

VSA en Kanada

Hierdie toestel voldoen aan Deel 15 van die FCC-reëls en aan RSS-210 van Industry Canada.

Operasie is onderhewig aan die volgende twee voorwaardes.

(1) hierdie toestel mag nie skadelike steurings veroorsaak nie, en

(2) hierdie toestel moet enige steuring wat ontvang word aanvaar, insluitend steuring wat ongewenste werking kan veroorsaak.

Unauthorized modifications may void the authority granted under Federal Communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Inligting oor blootstelling aan radiofrekwensie straling: Hierdie toerusting voldoen aan FCC- en IC-stralingsblootstellingslimiete wat vir 'n onbeheerde omgewing uiteengesit is. Hierdie toerusting moet geïnstalleer en bedryf word met 'n minimum afstand van 20 cm tussen die verkoeler en jou liggaam. Hierdie sender moet nie saamgeplaas word of saam met enige ander antenna of sender werk nie.

LET WEL: Veranderinge of wysigings wat aan hierdie toerusting aangebring is wat nie uitdruklik deur FEIG ELECTRONIC GmbH goedgekeur is nie, kan die FCC-magtiging om hierdie toerusting te gebruik, ongeldig maak.

Installation with FCC / IC Approval

FCC-/IC-NOTICE: To comply with FCC-Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States / Canada.

Etiketinligting

  • UThe following information must be placed at the outer side of the housing in which the reader is mounted.
  • Contains FCC ID PJMPRM103 Contains FCC ID PJMMRM103
  • Contains IC: 6633A-PRM103 Contains IC: 6633A-MRM103

Tegniese data

Meganiese data
Housing PR103 / MR103 Plastiek ABS
Gewig

PR103 MR103

150 g

150 g

Dimension PR103 / MR103

(wxhxd)

(145 x 85 x 22) mm
Dimension PR103 / MR103 Module

(wxhxd)

(145 x 77 x 17) mm
Weight Modul 56 g
Protection class PR103 / MR103 IP 30
Kleur behuising RAL 9018 (wit)
Elektriese data
Kragtoevoer

·         ID PR103-USB

·         ID MR103-A/-USB

·         ID MRM103-A/-USB

·         ID MR103-E

·         ID MR103-USBC

 

·         5V DC

·         12V DC up to 24V DC

·         12V DC up to 24V DC

·         12V DC up to 24V DC

·         Via USB-Type-C (Current at 1.5A)

Kragverbruik

ID PR103-USB ID MR103-A, USB, USBC, E

maks. 2.5W maksimum. 6W
Antenne

PR(M)103-USB

geïntegreer
Antenne connector MR(M)103 1x SMA-socket (50 W)
Voorsiening voltage on antenna output

MR103

6,9V DC ± 1V (5 mA) Antenna output
Bedryfsfrekwensie

PR103-USB ID MR103-A, USB, USBC, E

13,56 MHz
Oordragkrag

ID PR103-USB

ID MR103-A, USB, USBC, E

0.6W ± 2dB

1,2W ± 1dB

1,5W ± 1dB

Supported transponder ISO15693, (ISO 18000-3 MODE 1), I-CODE1
Reader modes

ID PR(M)103-USB

ID MR(M)103-A, USB, USBC, ID MR(M)103-E

ISO Host Mode, Scan Mode ISO Host Mode, Scan Mode

ISO Host Mode, Notification Mode

1 x LED's 1 x multicolor LED; (green, blue, red)
Koppelvlakke

·         ID PR(M)103-USB

·         ID MR(M)103-A

· USB

·         RS232

·         ID MR(M)103-USB

·         IS MR(M)103-USBC

·         ID MR(M)103-E

· USB

· USB

·         Ethernet (TCP/IP)

Kenmerk Short-circuit detection (antenna)

Temperatuur monitering

Omgewingstoestande
Temperatuurreeks -25°C tot +55°C

-40°C tot +85°C

Operasie berging
Relatiewe lugvogtigheid 5% – 95% (niekondenserend)
Vibrasie EN60068-2-6

10 Hz bis 150 Hz: 0,075 mm / 1 g

Skok EN60068-2-27

Versnelling: 30 g

Goedkeurings
Radio goedkeuring ·         EN 300 330

·         FCC 47 CFR-Part 15

·         RSS-Gen Issue 1, RSS-210

·         Europa / UK

·         USA

·         Canada

EMV EN 301 489
Veiligheid en Gesondheid EN 62368-1

EN 50364

EN 18031

Lae voltage Menslike blootstelling

Cyber Security (MR103-E)

Bykomstighede

Bestelnr. Tik Beskrywing
1688.002.00 ID NET.12V-B-EU Power Supply Unit 12V Supply unit 100 – 240V AC, (Angled plug, EU),

Output: 12V DC/      ; 50Hz / 60Hz, 700mA

3886.000.00 ID NET.12V-B-GB Power Supply Unit 12V Supply unit 100 – 240V AC, (Angled plug, GB)
3887.000.00 ID NET.12V-B-US Power Supply Unit 12V Supply unit 100 – 240V AC, (Angled plug, US)
7224.000.00 ID MS.MR103/PR103-A Wall mounting or under-counter mounting
7102.000.00 ID CAB.RS-T Cable for RS232 and Power Supply (ID MR103-A)
7103.000.00 ID CAB.USB-AC USB Interface cable, USB-A auf USBC
7104.000.00 ID CAB.USB-CC USB Interface cable, USBC auf USBC
Eksterne antennes
1663.000.00 ID ISC.ANT340/240-A Dim.: Protection.: 340mm x 240mm x 9mm IP20
2396.000.00 ID ISC.ANT340/240-B Eksterne antenna sonder behuising
3249.000.00 ID ISC.ANT310/310-A Dim.: Protection.: 318mm x 338mm x 30mm IP65
3512.000.00 ID ISC.ANTS370/270 Dim.: Protection.: 370mm x 270mm x 27mm IP20
6612.000.00 ID ANT240/180-A Dim.: Protection: 40mm x 180mm x 13mm IP30
6616.000.00 ID ANTS240/180-A Dim.: Protection: 240mm x 180mm x 15mm IP30
1968.000.00 ID ISC.ANT100/100-A External antenna without housing Dim.:                40mm x 30mm x 6mm
1967.000.00 ID ISC.ANT40/30-A Eksterne antenna sonder behuising

Dim.:                100mm x 100mm x 6mm

Oortjie 10: Bykomstighede

Wall mounting or under counter mounting

  • Remove the screws on the back of the reader.
  • The mounting brackets are fastened with the previously removed screws.
  • They can also be mounted rotated by 90° as an option.

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (12)

Let wel: The mounting kit “ID MS.MR103/PR103-A” includes the four mounting brackets (See Accessories).

Serial Data Cable ID CAB.RS-T

PIN Sein Farbe / Color X2
1 GND Geel FEIG-MRM103-Mid-Range-Reader-Module-FIG- (13)
2 RxD Oranje
3 TxD Bruin
4 GND Swart
5 12 bis 24V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2) Rooi

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (14)

  • Dokument: Installasie
  • Id-Nr. Document Version: M50720-0e-ID-B
  • Datum: 30.10.25

KONTAKINLIGTING

  • © Kopiereg
  • All brand names, product names or trademarks mentioned are the property of their respective owners.
  • FEIG ELECTRONIC GmbH
  • Industriestraat 1a
  • 35781 Weilburg, Duitsland
  • Tel.: +49 6471 3109-0
  • Tuisblad: https://www.feig.de/en/
  • E-pos: identification-support@feig.de.

Gereelde vrae

  • Kan ek wysigings aan die toestel maak?
    • No, unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
  • Who can perform repairs on the device?
    • Herstelwerk mag slegs deur die vervaardiger uitgevoer word.
  • What should I do before handling the device?
    • Voordat u aan die toestel raak, moet die kragtoevoer altyd onderbreek word. Maak seker dat die toestel sonder voltage by measuring. The fading of an operation control (LED) is no indicator for an
    • interrupted power supply or the device being out of voltage!
  • Waar kan ek die nuutste weergawe van die handleiding kry?
    • With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. For the most current information, it is recommended to contact FEIG ELECTRONIC GmbH.

Dokumente / Hulpbronne

PDF thumbnailMRM103 Mid Range Reader Module
Installation Guide · PJMPRM103, PRM103-USB, MRM103-USB, MR103-A, MR103-E, MR103-USBC, M50720-0e-ID-B, MRM103 Mid Range Reader Module, MRM103, Mid Range Reader Module, Mid Range Reader Module, Reader Module, Module

Vra 'n Vraag

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Vra 'n Vraag

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.