ENKOA Vs4 Motion Sensor User Guide

ENKOA Vs4 Motion Sensor User Guide

ENKOA-logo

ENKOA Vs4 Motion Sensor

ENKOA-Vs4-Motion-Sensor-product

GENERAL WARNINGS AND INSTRUCTION GUIDE
Read carefully the instruction given, before installing and using the motion sensor and hold it for future references.
In order to ensure the correct operation of the product in your installation is necessary to carry the following safety regulations out:

  1. The installation and the use of the product must be done according to the technical operating conditions explained below.
  2. The good use of the application is client’s responsibility.
  3. After reception of the goods, check the packaging and the existing material in case there is any damage. Check as well, that the reception is complete (accessories, papers, etc).
  4. If packaging is damaged during delivery or it is suspicious of being damaged or having a failure, do not put the unit on. In that case please contact us.
  5. The installation and handling of our product has to be done by authorized personnel. Mainly the electrical connections must be done only by qualified experts.
  6.  Do not try to repair any material after a failure or damage and put it working again. In this case it is highly important to contact us.
  7. There will not be accepted any responsibility for damages caused by a wrong use.

Ensure that the top and the low caps are unified and correctly screwed before starting the unit up.

INLEIDING

Kort beskrywing
The MOTION SENSOR is a passivinfrated detector device that detects people movement through the room. In addition, it features a thermostat that measures room temperature and humidity. It has a wireless communication with the Swatch energy saver and sends movement information and the room temperature to the energy saver. The energy saver enables connect or disconnect the room devices depending on the information sent by the motion sensor. The MOTION SENSOR is standalone and is operated by 3 batteries of 1.5 V LR3 AAA (non rechargeable).

ENKOA-Vs4-Motion-Sensor- (1)

 Shipment content 

  • BEWEGINGS SENSOR
  • Screw box (2 screws and 2 number five plugs to fix it in the ceiling. 1 side screw to close the cap.)
  • User’s and starting up user’s guide.

INSTALLASIE

  • The MOTION SENSOR will be always overhead mounted.
  • The MOTION SENSOR’S installation is made through 2 screws and 2 plugs. It is required to drill 2 holes of 5 mm thick in the wall, introduce the plugs inside the holes and screw the top cover to the ceiling.
  • The sensor’s cover is released by turning the lower part slightly anticlockwise. ENKOA-Vs4-Motion-Sensor- (2)
  • The SENSOR installation position must be taken into consideration. Following is explained the detection coverage for locating it. It may require more that one sensor per room, depending on the room structure. ENKOA-Vs4-Motion-Sensor- (3)
  • The shaded parts show the motion sensor’s detection area.

It belongs to the round area on the floor with a diameter equal to the sensor installation Height.

Detection  = Mounting height x 2
Maximum Mounting Height = 4 meters

Monteerhoogte Opsporing 
2.5 XNUMX meter 5 XNUMX meter
3 XNUMX meter 6 XNUMX meter
4 XNUMX meter 8 XNUMX meter

Afmetings
The dimensions and assembly points are shown in the picture below.

ENKOA-Vs4-Motion-Sensor- (4)

Installasie proses
The MOTION’S SENSOR installation must be done as follows:

  1. Mark two holes on the ceiling with a 35mm distance between them.
  2. Drill two holes of 5mm thick with M5 drillbit.
  3. Place it including the plugs in the holes.
  4.  Dismantle the SENSOR by separating the top part from the lower part. Turn it slightly anticlockwise.
  5. Place the top cover in the ceiling and screw it using two fixing screws.
  6.  SENSOR AND ISWITCH SYNCHRONIZING (Energy saver)…
    • To configure the Switch Energy Saver in Synchronization mode, refer to the corresponding manual for each energy saver.
    • While the switch Energy saver is SYNC mode, push the inner button of the energy saver with the hand. The red pilot will go on.
    • Then the sensor and the energy saver will try to synchronize. The synchronizing will be correct when the sensor blinks red quickly that last around five seconds. Finally the red pilot must go off.
    • Repeat it with all the sensor of the same room that must be synchronized with the same energy saver.
  7. Place back the lower sensor cover on the top cover turning it clockwise. Make sure that the holes for the side screw coincide.
  8.  Screw the side screw to lock the top and lower cover.

Note ( Sensor desynchronization)
To perform the desynchronization or erasure of the sensors in the Switch Energy saver, refer to the corresponding manual of each energy saver. The energy saver deletes the list of the synchronized sensors.

The desynchronization will be necessary in the following situations:

  • One it is desired to delete one of the room sensors.
  • One a sensor is damaged and is changed by a new one.
  • After the desynchronization, it is always necessary to synchronize the room sensor with the new energy saver.

The desynchronization is NOT necessary in the following cases:

  • When the sensor’s batteries are changed.
  • When a new sensor is added to the room.

BEDRYF

The MOTION SENSOR is connected wirelessly to the ISWITCH energy saver. The operation modes are the following:

  1. Stoormodus
    The MOTION SENSOR is detecting continuously movement inside the room. If during the configuration time no movement is detected within the room, the iswitch disconnects the relay 2 that is usually connected to the air conditioning or to other high consuming device.
  2. Room comfort option
    The energy saver must be pre-configured in this mode for the system to work correctly. In Comfort mode, the volumetric sensor acts by sending the room’s temperature and humidity information to the iSwitch energy saver. The Switch enables or disables the configured relay or relays whenever there is no presence in the room, maintaining the pre-set comfort temperature.
  3.  Sekuriteit Opsie
    If the  Switch energy saver is configured in Security mode, it is possible to know if there has been any intrusion while the client is not in the room. If there is no card inserted in the energy saver and the volumetric sensor detects movement, the Switch enables one or several relays as the intrusion alarm signal.

ONDERHOUD EN SKOONMAAK

  • For a long lasting device, please follow these instructions:
  • Make sure the optic is clean and there is no object glued to it.
  • Replace the batteries every two years or when the sensor asks by red blinking.

Battery vervanging
When the batteries are about to run out, the sensor warns the users to change them. The optic’s pilot makes three red blinkings every eight seconds showing low battery. In order to replace the batteries, please follow the next steps:

  • Let loose the side screw that locks the sensor’s cover.
  • Hold the low part of the cover and turn it anticlockwise.
  • Once you have the lower cover at your hand replace the 3 AAA batteries. Replace it with batteries of the same supplier. Caution: make sure that batteries with the same polarity are used.ENKOA-Vs4-Motion-Sensor- (5)
  • Place again the lower cover on the front cover by turning it clockwise. Keep in mind to coincide the holes for the side screw.
  • Screw the side screw.

TEGNIESE DATA

BESKRYWING Wireless motion sensor for the energy saver
VERWYSING SVOEIxS
KRAGVOORSIENING 3 batteries of AAA LR3 1,5 V
OUTONOMIE 4 years ( Average consumption 30uA, max. 20mA)
COMUNICATIONS Wireless 2,4 GHz , IEEE 802.15.4
COMMUNICATIONS COVERAGE 10m ( Max. distance to the energy saver)
INTERFACE Rooi gelei
TEMPERATURE/HUMIDIT Y REEKS Temperature: -40° to 160° Humidity: 0 % raH to 100 % rH
TEGNOLOGIE Infrared passive detector. Fresnel lens
OPSPEURINGSDEKKING Æ6m if 3m height mounted (coverage depending on the mounting height )
MONTERINGSHOOGTE Between 2,5 -4m
THERMOSTAT ACCURACY Temperature: ±0.5° (15° to 40°), ±1° (0° to 60°)Humidity: ±3.5% (20% to 80%)
AFMETINGS Æ 111mm x 40mm
GEWIG 120 gr.

 TIPPS FOR PROTECTING THE ENVIRONMENT

  • ENKOA-Vs4-Motion-Sensor- (6) The batteries can be damaging if they are not disposed adequately.
  • Protect the environment by throwing the run-out batteries in an authorized collecting point.
  • For long lasting batteries, when low battery is detected, do change all the batteries.

BEDRYFS VOORSORGMAATREËLS

Basiese Beginsels
PaPIRs is a pyroelectric infrared sensor that detects variations in infrared rays. However, it may not detect in the following cases: lack of movement, no temperature change in the heat source.
Besides, it could also detect the presence of heat sources other than a human body. Efficiency and reliability of the system may vary depending on actual operating conditions:

  1. Detecting heat sources other than the human body, such as:
    • Small animals entering the detection area
    • When a heat source for example sun light, incandescent lamp, car headlights etc, or strong light beam hit the sensor regardless inside or outside the detection area.
    • Sudden temperature change inside or around the detection area caused by hot or cold wind from HVAC, or vapor from the humidifier, etc.
  2. Moeilik om die hittebron te waarneem
    • Glass, acrylic or similar materials standing between the target and the sensor may not allow a correct transmission of infrared rays,
    • Non-movement or quick movements of the heat source inside the detection area.
  3. Expansion of the detection area
    • In case of considerable difference in the ambient temperature and the human body temperature, detection area may be wider apart from the configured detection area.

REGULATIESE INLIGTING

  • FCC ID: 2ASEQSVOXIXS
  • IC: 24733-SVOXIXS
  • HVIN: SVOEIxS

FCC Compliance Statement (§15.19)
Hierdie toestel voldoen aan Deel 15 van die FCC-reëls. Werking is onderhewig aan die volgende twee voorwaardes:

  1. Hierdie toestel mag nie skadelike steurings veroorsaak nie, en
  2. Hierdie toestel moet enige steuring wat ontvang word aanvaar, insluitend steuring wat ongewenste werking kan veroorsaak.

 ISED Compliance Statement (RSS-Gen)
Hierdie toestel bevat lisensievrygestelde sender(s)/ontvanger(s) wat aan Innovation, Science and Economic Development Kanada se lisensievrygestelde RSS(s) voldoen. Werking is onderhewig aan die volgende twee voorwaardes:

FCC Class B Digital Device Notice (§15.105)
Hierdie toerusting is getoets en gevind dat dit voldoen aan die limiete vir 'n Klas B digitale toestel, ingevolge Deel 15 van die FCC Reëls. Hierdie perke is ontwerp om redelike beskerming teen skadelike inmenging in 'n residensiële installasie te bied. Hierdie toerusting genereer, gebruik en kan radiofrekwensie-energie uitstraal en, indien dit nie geïnstalleer en gebruik word in ooreenstemming met die instruksies nie, kan dit skadelike steurings vir radiokommunikasie veroorsaak. Daar is egter geen waarborg dat inmenging nie in 'n spesifieke installasie sal voorkom nie. Indien hierdie toerusting wel skadelike steurings vir radio- of televisie-ontvangs veroorsaak, wat bepaal kan word deur die toerusting af en aan te skakel, word die gebruiker aangemoedig om die steuring deur een of meer van die volgende maatreëls te probeer regstel:

  • Heroriënteer of verskuif die ontvangsantenna.
  • Verhoog die skeiding tussen die toerusting en ontvanger.
  • Koppel die toerusting aan 'n uitlaat op 'n stroombaan anders as dié waaraan die ontvanger gekoppel is.
  • Raadpleeg die handelaar of 'n ervare radio-/TV-tegnikus vir hulp.

FCC Modification Warning (§15.21)
Waarskuwing: Veranderinge of wysigings wat nie uitdruklik goedgekeur is deur die party wat verantwoordelik is vir voldoening nie, kan die gebruiker se magtiging om die toerusting te gebruik, vernietig.

RF Exposure Statement (§2.1093)
This equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The device has been evaluated to meet the general RF exposure requirements. The device can be used in portable exposure conditions without restriction.

Gereelde vrae

  • Q: How do I install the Motion Sensor?
    A: The sensor is overhead mounted. You’ll need to drill two 5mm holes 35mm apart, insert plugs, and then screw the top cover to the ceiling. The sensor’s cover is released by turning the lower part slightly anticlockwise.
  • V: Wat is die opsporingsreeks van die sensor?
    A: The detection range is approximately twice the mounting height. For example, at a 2.5-meter mounting height, the detection is 5 meters; at 4 meters, it’s 8 meters.
  • Q: When should I desynchronize the sensor from the energy saver?
    A: Desynchronization is needed if you want to remove a sensor from a room or if a sensor is damaged and replaced. You will then need to re-synchronize the new or remaining sensors.
  • Q: Is desynchronization required when changing batteries or adding a new sensor?
    A: No, desynchronization is not necessary when changing batteries or adding a new sensor to the room.
  • Q: How does the saving mode work?
    A: In saving mode, the sensor continuously detects movement. If no movement is detected for a configured period, the iSwitch energy saver will disconnect devices like air conditioning to save energy.

Dokumente / Hulpbronne

PDF thumbnailVs4 Motion Sensor
User Guide · SVOXIXS, 2ASEQSVOXIXS, Vs4 Motion Sensor, Vs4, Motion Sensor, Sensor

Verwysings

Vra 'n Vraag

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Vra 'n Vraag

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.