AiM LCU1S Lambda-beheerder Gebruikersgids

AiM LCU1S Lambda Controller User Guide

AiM-logo

AiM LCU1S Lambda Controller

AiM-LCU1S-Lambda-Controller-product

Produk inligting

 Inleiding

  • LCU1S is the new smaller, lighter and faster AiM Lambda Controller expansion supported by all the last car-bike AiM devices.
    Neem asseblief kennis: the only systems that does not support LCU1S are MXL, MXL2 and MyChron.
  • LCU1S allows you to perfectly tune the carburation of the engine as well as to improve the engine performances.
  • LCU1S gebruik 'n Bosch LSU4.9-sonde wat die oorspronklike kalibrasie vir die duur van die sensor se leeftyd bewaar en meer as 100 000 km op 'n standaardmotor hou.

Beskikbare stelle, opsionele items en onderdele

Available LCU1S kits are:

  • LCU1S complete kit; part number: X08LCU1SAC090
    • LCU1S
    • Bosch LSU 4.9 Lambda-sonde
    • Draad ysterring vir installasie

LCU1S kit without Lambda probe; part number: X08LCU1SAC0

  • LCU1S

Optionals7 and spare parts:

  • Bosch LSU 4.9 Lambda probe X05LSU490
  • Thread iron ring for installation LBS552680
  • 50cm AiM CAN cable V02552690
  • 100cm AiM CAN cable V02552700
  • 200cm AiM CAN cable V02552720
  • 400cm AiM CAN cable V02551070

Configuring LCU1S

LCU1S can only be configured using AiM RaceStudio 3 software you can freely download from AiM webwebwerf by www.aim-sportline.com aflaai sagteware/firmware area.
LCU1S is an expansion that is to be loaded on AiM device configuration so first of all run the software and select the configuration where to load LCUS1S on or create a new one as shown here below. To create a new configuration:

  • Press “New Configuration” (1)
  • Select the device you are configuring (Solo 2 DL v2 in the example below 2)
  • Druk "OK" (3)

AiM-LCU1S-Lambda-Controller- (1)

Die sagteware gaan na die "Kanale"-oortjie.

AiM-LCU1S-Lambda-Controller- (2)

To load LCU1S activate “CAN Expansions” (1) tab as shown here below and follow these steps:

  • Press “New Expansion” (2)
  • Select LCU1S (3)
  • Druk "OK" (4)

AiM-LCU1S-Lambda-Controller- (3)

Once the expansion added, the software enters the related tab (0LC1S). Here it is possible to:

  • Get the serial number of LCU1S or fill it in manually (1); please note: to get the serial number from the connected LCU1S it is necessary to power it and connect the master device LCU1S is connected to your PC via Wi-Fi (or via USB). Please refer to the user manual of each logger to know how to manage Wi-Fi connection;
    • select the multiplier to calculate AFR from Lambda value
    • manage custom values through the dedicated panel that is prompted clicking the proper button
  • As far as the channel table (2) is concerned, clicking on each channel it is possible to set samplingfrekwensie, meeteenheid en vertoonpresisie.

AiM-LCU1S-Lambda-Controller- (4)

How to get the serial number of a connected LCU1S

To get the serial number of the connected LCU1S ensure that LCU1S is powered and connect the master logger to the PC. To do so:

  • click the Wi-Fi icon top right of the software view (or plug the USB cable of the logger in the PC USB port)
  • Select the logger to connect via Wi-Fi and press “Connect”.
  • AiM-LCU1S-Lambda-Controller- (5) Once the logger connected press “Get Expansion Serial Number” as shown here below
  • A panel is prompted: select the connected expansion to configure and press “OK”AiM-LCU1S-Lambda-Controller- (6)
  • the software comes back to “CAN Expansions” tab and shows LCU1S Serial number.AiM-LCU1S-Lambda-Controller- (7)

Aanlyn view en firmware-opdatering

Once LCU1S connected and identified it is suggested to complete, save and transmit the configuration to the logger. This procedure changes according to the logger that is being configured.
Nou is dit moontlik om aanlyn in te skryf view and check LCU1S values. To do so:

  • voer "Konfigurasies" in view
  • Press the logger you are configuring as shown here below.

AiM-LCU1S-Lambda-Controller- (8)

The software enters Online view:

  • Activate “Firmware” tab
  • Die view shows the logger and its expansions on the right part of the view soos hieronder getoon.

AiM-LCU1S-Lambda-Controller- (11)

To update both logger and expansions firmware:

  • click the related button top right of the view
  • AiM-LCU1S-Lambda-Controller- (12)the software enters firmware update view where it is possible to download and install the firmware as for any AiM device.

AiM-LCU1S-Lambda-Controller- (13)

Tegniese spesifikasies en tekeninge

LCU1S technical specifications are

  • Sensor compatibility Bosch LSU4.
  • Kragtoevoer voltage 9-15V
  • Power supply current 50mA ÷ sensor heater typical current 750 mA up to 2A on cold sensor
  • Reaction time Less than 10msec
  • Material Latigloss 57
  • Dimensions 43.4x30x18.4 mm
  • Gewig 70g
  • Waterdig IP67

LCU1S Dimensions in mm [inches]

AiM-LCU1S-Lambda-Controller- (9)

LCU1S Pinout

AiM-LCU1S-Lambda-Controller- (10)

Gereelde Vrae

Which AiM devices are not compatible with LCU1S?

MXL, MXL2, and MyChron are the systems that do not support LCU1S.

What is the lifespan of the Bosch LSU4.9 probe?

The probe lasts for more than 100,000 km on a stock car.

Dokumente / Hulpbronne

PDF thumbnailLCU1S Lambda-beheerder
User Guide · X08LCU1SAC090, X08LCU1SAC0, X05LSU490, LCU1S Lambda Controller, LCU1S, Lambda Controller, Controller

Verwysings

Vra 'n Vraag

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Vra 'n Vraag

Ask a question about setup, compatibility, troubleshooting, or anything missing from this manual.