GEBEURTENISBELIGING-LOGO

EVENT LIGHTING APRO4-IP DMX Controller

EVENT-LIGHTING-APRO4-IP-DMX-Controller-PRODUCT-IMAGE

Vir u veiligheid, lees asseblief hierdie gebruikershandleiding sorgvuldig voor gebruik.
Event Lighting behou die reg voor om die handleiding te eniger tyd te hersien. Inligting en spesifikasies in hierdie handleiding is onderhewig aan verandering sonder kennisgewing. Event Lighting aanvaar geen aanspreeklikheid of verantwoordelikheid vir enige foute of weglatings nie. Raadpleeg asseblief Event Lighting vir enige verduideliking of inligting rakende hierdie item.

KENMERKE

  • DMX 512, RDM, Artnet and sACN support
  • Afstandopstelling via intern webbladsy
  • Update firmware on Webbladsy
  • DMX output isolation
  • RJ45 Ethernet B input with POE(DC12V 2A)
  • LCD-skerm
  • Gigabit network, 100/1000mbps port speed
  • IP65-gradering

PANEEL OORVIEW

EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (1)EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (2)

  1. Ethernet port RJ45
  2. Ethernet port RJ45
  3. Power in/out True1
  4. 2xDMX5pin connectors
  5. 2xDMX5pin connectors
  6. Sekeringhouer
  7. LCD Display protection cover

SPYSKAARTE
Below is controller Menus map

HoofSpyskaart Subkieslys 1 Subkieslys 2 Waarde/Opsie Verstek
Netwerk IP-modus DHCP Staties
Staties
IP-adres 2.xx.xx.xx 2.xx.xx.xx
Subnet masker 255.0.0.0 255.0.0.0
DMX-poort Protokol Artnet Artnet
SACN
Start Net 000-127 000
Begin Heelal 000-255 000
Poort 1 Modus Af On
On
NET 000-127 000
Heelal 000-255 000
Poort 2 Modus Af On
On
NET 000-127 000
Heelal 000-255 001
Poort 3 Modus Af On
On
NET 000-127 000
Heelal 000-255 002
Poort 4 Modus Af On
On
NET 000-128 000
Heelal 000-255 003
Deaktiveer
Instellings DMX koers 20Hz 30Hz
25Hz
30Hz
35Hz
40Hz
RDM Deaktiveer Deaktiveer
Aktiveer
Vertoon aan Altyd 1 min
30Sek
1 min
5 min
Seinverlies Hou DMX vas Hou DMX vas
Stop Output
Voeg modus saam PH PH
LTP
Fabrieksterugstelling Nee Nee
Ja

WEB konfigurasie

NET device network IP mode can set to DHCP mode or Static mode.

DHCP -modus

  • When APRO4‐IP is set to DHCP mode, you need to set the computer to DHCP also. And use a router for linking computer and APRO4‐IP device. The controller will show IP address like below: EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (3)
  • Enter IP address in your web browser, then you can login webpage to configure the parameter of controller. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (4)

Voer wagwoord in: admin

Statiese modus

  • When APRO4‐IP device is set to Static mode, you need to set computer to be Static mode also. APRO4‐IP device will show IP address as below: EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (5)
  • Then set the IP address of computer is in the same IP range manually. For example: IP address must start with 2 according to APRO4‐IP address. And netmask is same with 255.0.0.0. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (6)
  • Input static IP address of APRO4‐IP device in your browser, then you can login to configure the parameter of device.

Voer wagwoord in: admin EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (7)

  • When log on NET Config web, the first page show the information about APRO4‐IP. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (8)
  • Following  is  for  Network  setting,  you  can  set  IP  mode  to  be  Static  or  DHCP,  IP  Address,and Subnet Mask. After setting, click Save button . EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (8)
  • For DMX Port page , it is used for DMX Port setting. You can select Protocol to be Artnet or sACN, and set each port as input or output. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (10)
  • On the page of Setting , you can set DMX Rate, RDM , Display On and Signal Loss. After setting, click Save to store the setting.
  • DMX  Rate:  You  can  set  20Hz,  25Hz,  30Hz,  35Hz,  40Hz,  30Hz  is default setting.
  • RDM: You can set RDM to be Disable or Enable.
  • There is 4 options for Display On mode: Always, 30Sec, 1Min, 5Min.
  • Seinverlies: Can set as Hold DMX or Stop Output. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (11)
  • You can return to factory setting by click Factory Reset button. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (12)
  • On Update page, you can update software of fixture by selecting the update software file of APRO4‐IP.
  • On the last page, you can reset password. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (13)

SPESIFIKASIE

  • Krag in: AC 100‐240V,50/60Hz
  • Kragverbruik: AC240V 50HZ 0.05A
  • Grootte: 215.3×150.5x42mm 4.2W
  • Gewig: 1.43 kg
  • POE 802.3af
  • IP65

AFMETINGS

EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (14)

Waarborg

Verwys asseblief na jou plaaslike handelaar of kontak Event Lighting. www.event‐lighting.com.au

Gereelde Vrae

How do I reset the APRO4-IP device to factory settings?

To perform a factory reset on the APRO4-IP device, access the Factory Reset option in the Main Menu under Settings. Confirm the reset to restore the device to its default configuration.

What is the default IP address for the APRO4-IP device?

The default IP address for the APRO4-IP device is set to DHCP mode. If you switch to Static mode, you can set a specific IP address within the range provided in the user manual.

Dokumente / Hulpbronne

EVENT LIGHTING APRO4-IP DMX Controller [pdfGebruikershandleiding
APRO4-IP, APRO4-IP DMX Controller, DMX Controller, Controller

Verwysings

Los 'n opmerking

Jou e-posadres sal nie gepubliseer word nie. Vereiste velde is gemerk *