1. Produk verbyview
The BN-LINK CP-SU67D is an indoor astronomical digital programmable timer designed for automated control of various indoor appliances. It features up to 18 ON/OFF programs, astronomical timing for automatic sunrise/sunset adjustments, and support for six U.S. time zones. This timer also includes automatic Daylight Saving Time (DST) adjustment and an internal battery backup to retain settings during power outages.
Sleutel kenmerke:
- Astronomiese tydsberekening: Automatically adjusts ON/OFF times based on sunrise and sunset data.
- Multi-Zone Accuracy: Supports six U.S. time zones (PAC, MOU, CEN, EAS, HAW, ALA) for precise local scheduling.
- 18 ON/OFF Programs: Create up to 18 independent timer schedules for various devices.
- Buigsame skedulering: Offers weekly and daily settings for comprehensive control.
- Bedryfsmodusse: Easily switch between Auto, Manual, and Random modes.
- Ewekansige modus: Varies ON/OFF times by 0-30 minutes for enhanced security when away.
- DST Adjustment: Automatically shifts between standard and daylight saving time.
- Internal Battery Backup: Retains current time and program settings during power interruptions.
- Safe Power Rating: 125V 60Hz, 15A/1875W resistive, suitable for lamps, coffee makers, fans, and small indoor appliances.
Pakketinhoud:
- BN-LINK CP-SU67D Digital Programmable Timer
- Gebruikershandleiding
2. Belangrike veiligheidsinstruksies
Please read and understand all instructions before using this product. Failure to follow these instructions may result in electric shock, fire, or serious personal injury.
- Slegs binnenshuise gebruik: This timer is designed for indoor use in dry locations. Do not expose to rain, moisture, or wet conditions.
- Elektriese gradering: Do not exceed the electrical ratings of 125V, 15A, 1875W. Overloading the timer can cause overheating and fire.
- Aarding: Ensure the timer is plugged into a properly grounded 3-prong outlet.
- Kinders: Hou buite bereik van kinders.
- Skoonmaak: Unplug the timer from the outlet before cleaning. Use a dry cloth only.
- demontage: Do not attempt to disassemble or repair the unit. Refer all servicing to qualified service personnel.
- Toestelversoenbaarheid: Ensure the appliance connected to the timer is suitable for unattended operation.
3. Produkkomponente
Familiarize yourself with the various parts of your BN-LINK CP-SU67D timer:

- Vertoon skerm: Shows current time, day, mode, and program settings.
- Knoppies: Used for setting time, programs, and modes (SET, PROG, D/D, Reset, ON/OFF, +, -).
- Red Power Indicator Light: Verlig wanneer die toestel aangeskakel is.
- Green Operation Indicator Light: Illuminates when the timer is actively controlling a connected device (e.g., turning it ON).
- uitlaat: Where you plug in the appliance to be controlled.
4. Aanvanklike Opstelling
4.1 Laai die interne battery
Before first use, plug the timer into a live electrical outlet for at least 30 minutes to charge the internal battery. This battery maintains the clock and program settings during power outages of wanneer die timer ontkoppel is.
4.2 Clearing All Memory
To clear all previous settings and reset the timer to factory defaults, use a small pointed object (like a pen tip) to press the Stel terug button located on the front of the timer. This is recommended for initial setup or if you encounter programming difficulties.
4.3 Instelling van Huidige Tyd en Dag
- Druk en hou die STEL button for 3 seconds until the clock display starts flashing.
- Gebruik die + en - buttons to adjust the current hour.
- Druk STEL again to move to minute adjustment, then use + en -.
- Druk STEL again to move to day adjustment (MO, TU, WE, TH, FR, SA, SU), then use + en -.
- Druk STEL een laaste keer om te bevestig en tydinstellingsmodus te verlaat.
4.4 Stel Tydsone
The timer supports six U.S. time zones for accurate astronomical timing. To set your time zone:

- Druk en hou die D/D button for 3 seconds. The current time zone abbreviation will flash on the display.
- Gebruik die + or - buttons to cycle through the available time zones (PAC, MOU, CEN, EAS, HAW, ALA).
- Once your desired time zone is displayed, press D/D weer om te bevestig en af te sluit.
4.5 Aanpassing van dagligbesparingstyd (DST)
The timer automatically adjusts for Daylight Saving Time. No manual reset is needed.

- To manually enable/disable DST, press and hold the + button for 3 seconds. The 'DST' indicator will appear or disappear on the display.
5. Bedryfsinstruksies
5.1 Programmering van AAN/AF-gebeurtenisse
The timer allows for up to 18 independent ON/OFF programs. Each program can be set for specific days of the week or daily.

- Druk die PROG knoppie om programinstellingsmodus te betree. Die skerm sal '1 AAN' wys.
- Gebruik die + en - buttons to set the desired ON time for Program 1.
- Druk PROG weer. Die skerm sal '1 AF' wys.
- Gebruik die + en - buttons to set the desired OFF time for Program 1.
- Druk PROG again to select the days of the week for Program 1. Use + or - to cycle through options (e.g., MO TU WE TH FR SA SU, MO-FR, SA SU, individual days, etc.).
- Herhaal stappe 1-5 vir tot 18 AAN/AF-programme.
- Nadat al die verlangde programme ingestel is, druk die STEL button to exit program mode and return to the current time display.
5.2 Operating Modes (Auto, Manual, Random)
The timer offers three operating modes:

- Outomatiese modus: The timer operates according to your programmed ON/OFF schedules. The display will show 'AUTO'.
- Handmatige modus: Allows you to manually turn the connected appliance ON or OFF, overriding any programmed schedules. The display will show 'MAN'.
- Ewekansige modus: When enabled, this mode varies the programmed ON/OFF times by 0-30 minutes, simulating a 'lived-in' appearance for security purposes. The display will show 'RND'.
Om tussen modusse te wissel, druk die AAN/AF button repeatedly until the desired mode (AUTO, MAN, RND) is displayed.


5.3 Astronomical Dusk to Dawn Feature
The timer can automatically adjust ON/OFF times based on local sunrise and sunset. This feature is active when the timer is in Auto mode and the time zone is correctly set. The display will show 'D/D' when this feature is active for a program.

6. Onderhoud
6.1 Skoonmaak
To clean the timer, first unplug it from the electrical outlet. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners, aerosols, or harsh chemicals, as these may damage the unit or pose an electrical hazard.
6.2 Berging
When not in use, store the timer in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the internal battery is charged periodically if stored for extended periods to maintain its functionality.
7. Probleemoplossing
If you encounter issues with your BN-LINK CP-SU67D timer, refer to the following common problems and solutions:
- Timer not turning ON/OFF at programmed times:
- Maak seker dat die timer in is AUTO modus.
- Verify that the programmed ON/OFF times and days are correct.
- Check if the internal battery is sufficiently charged (plug in for 30 minutes).
- Confirm the connected appliance is working correctly when plugged directly into an outlet.
- Skerm is leeg of dof:
- Plug the timer into a live outlet to charge the internal battery.
- If the issue persists, the internal battery may need replacement or the unit may be faulty.
- Difficulty programming the timer:
- Perform a full reset by pressing the Stel terug knoop met 'n puntige voorwerp.
- Carefully follow the programming steps in Section 5.1. The sequence of button presses is crucial.
- Ensure you are pressing STEL to confirm each step (hour, minute, day) during time setting.
- To delete an unwanted program, navigate to that program number in PROG mode and set both ON and OFF times to '--:--' or reset the entire unit.
- Astronomical timing is inaccurate:
- Verify that the correct time zone is selected (refer to Section 4.4).
- Ensure the current time and day are set accurately.
- Note that astronomical timing adjusts based on general sunrise/sunset data for the selected time zone, not specific latitude/longitude.
- Random mode not working:
- Maak seker dat die timer in is RND modus.
- Random mode only applies to programmed ON/OFF events, not manual operation.
8. Spesifikasies
| Parameter | Waarde |
|---|---|
| Modelnommer | CP-SU67D |
| Gegradeerde Voltage | 125V AC 60Hz |
| Max. laai | 15A / 1875W (Resistive or General Purpose) |
| Materiaal | Plastiek |
| Produk afmetings | 2.5" D x 2.5" B x 4.3" H |
| Item gewig | 4.8 onse |
| Aantal programme | Tot 18 AAN/AF-programme |
| Battery | 1 Nonstandard Battery (included, for backup) |


9. Waarborg en Ondersteuning
9.1 Waarborginligting
BN-LINK products are designed to provide reliable performance. For specific warranty details regarding your CP-SU67D timer, please refer to the warranty card included with your purchase or visit the official BN-LINK webwebwerf.
9.2 Kliëntediens
If you have any questions, require assistance with setup, or encounter issues not covered in this manual, please contact BN-LINK customer support. Contact information can typically be found on the product packaging or the official BN-LINK webwebwerf.
- Aanlyn ondersteuning: Visit the BN-LINK official webwebwerf vir algemene vrae, produkregistrasie en ondersteuningsbronne.
- E-pos ondersteuning: Refer to your product packaging or the webwebwerf vir die kliëntediens e-posadres.