DEMULLER ANHUI-SPLITAC
DEMULLER 9000BTU 4-in-1 Split Air Conditioner & Heater User Manual
Model: ANHUI-SPLITAC
1. Inleiding
The DEMULLER 9000BTU 4-in-1 Split Air Conditioner & Heater is a versatile climate control system designed to provide year-round comfort. This unit features cooling, heating, dry, and fan modes, making it suitable for various environments up to 450 sq. ft. With its 17 SEER2 efficiency and R32 refrigerant, it offers powerful performance while minimizing energy consumption.



2. Veiligheidsinligting
Please read all safety warnings and instructions carefully before installing or operating this appliance. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.
- Professionele installasie: This mini-split unit requires professional installation. Do not attempt to install it yourself.
- Kragtoevoer: Maak seker dat die kragtoevoer ooreenstem met die eenheid se vereistes (115V).
- koelmiddel: This unit uses R32 refrigerant. Handle with care and only by certified professionals.
- Opruimings: Maintain adequate clearances around both indoor and outdoor units for proper airflow and maintenance.
- Kinders en Troeteldiere: Hou kinders en troeteldiere weg van die eenheid tydens werking en onderhoud.
3. Produkkomponente
The DEMULLER 9000BTU Split Air Conditioner system is shipped in two separate packages. Please verify all components are present upon delivery.

Package 1 (Indoor Unit Box)
- Binne-eenheid
- Hangbord
- Instruksie Handleiding
- Afstandbeheer
- Muurbedekking
Package 2 (Outdoor Unit Box)
- Buitelug Eenheid
- Dreineerpyp
- Kommunikasie draad
- Connection Pipe (x2)
- Muurmou
- Putty for blocking wall holes
- Band
- Skroewe (x6)
4. Opstelling en installering
IMPORTANT: PROFESSIONAL INSTALLATION IS NECESSARY. DO NOT INSTALL THIS UNIT BY YOURSELF. This mini-split unit ships in two packages (indoor & outdoor units), which may not arrive at the same time. Please ensure both packages have arrived before scheduling installation.
Installation involves mounting both the indoor and outdoor units, connecting refrigerant lines, electrical wiring, and drainage. Due to the complexity and the need for specialized tools and knowledge, installation must be performed by a qualified HVAC professional.
Eenheid Afmetings
Consider the following dimensions for proper placement and installation:

- Binne-eenheid: 7.48" D x 28.35" B x 11.42" H
- Buite-eenheid: 9.37" D x 24.8" B x 19.88" H
5. Bedryfsinstruksies
The DEMULLER Split AC unit offers multiple modes and features for optimal comfort, controlled via the included remote.
Bedryfsmodusse

- Outomatiese modus: Kies outomaties verkoeling of verhitting gebaseer op die omgewingstemperatuur.
- Koel modus: Provides cooling. Temperature range: 61°F to 86°F.
- Hitte modus: Provides heating. Effective in environments as low as -4°F.
- Droë (Ontvochtig) Modus: Verminder humiditeit in die kamer.
- Aanhangermodus: Sirkuleer lug sonder verkoeling of verhitting.
- Slaap stelling: Pas temperatuur en waaierspoed aan vir gemaklike slaap en energiebesparing.
- ECO -modus: Optimizes operation for maximum energy efficiency.
Fan Snelhede
- Laag
- Middel
- Hoog
- Turbo (for rapid cooling/heating)
Bykomende kenmerke
- 24-uur timer: Set the unit to turn on or off automatically at desired times.
- Stil werking: Designed for low noise levels, ensuring a peaceful environment.
- Outomatiese ontdooiing: Prevents ice buildup on the outdoor unit during heating operation in cold climates.
- Selfreinigende funksie: Helps maintain the cleanliness of the indoor unit's evaporator coil.

6. Onderhoud
Regular maintenance ensures the longevity and efficient operation of your DEMULLER Split AC unit.
Selfreinigende funksie
The unit features a self-cleaning function to prevent mold and bacteria growth on the indoor coil. Consult your remote control's specific instructions for activating this feature.

Filter skoonmaak
The air filters should be cleaned regularly (e.g., every two weeks or as needed) to maintain airflow and efficiency. Refer to the detailed instruction manual for steps on how to remove and clean the filters.
Professionele diens
It is recommended to have your unit professionally serviced at least once a year by a qualified HVAC technician to check refrigerant levels, clean coils, and inspect all components.
7. Probleemoplossing
If you encounter issues with your DEMULLER Split AC unit, refer to the following common troubleshooting tips. For more complex problems, contact a qualified technician.
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| Eenheid skakel nie aan nie | No power supply; Remote control batteries dead | Check circuit breaker; Replace remote batteries |
| Onvoldoende verkoeling/verhitting | Dirty air filters; Doors/windows open; Room size too large; Low refrigerant | Clean filters; Close openings; Verify room size is within 450 sq. ft.; Contact professional for refrigerant check |
| Ongewone geraas | Los dele; Obstruksie in waaier; Eenheid nie gelyk nie | Inspect unit for loose components; Remove obstructions; Ensure unit is level; Contact professional if noise persists |
| Water lekkasie | Verstopte dreinpyp; Onbehoorlike installasie | Check and clear drain pipe; Contact professional for installation inspection |
8. Spesifikasies
Detailed technical specifications for the DEMULLER 9000BTU Split Air Conditioner & Heater.
| Spesifikasie | Waarde |
|---|---|
| Handelsnaam | DEMULLER |
| Model inligting | ANHUI-SPLITAC |
| Produk Afmetings (Binnenshuis) | 7.48 x 28.35 x 11.42 duim |
| Doeltreffendheid | 17 SEER2 |
| Kapasiteit | 0.75 ton (24 000 BTU) |
| Installasie tipe | Gesplete stelsel |
| Vormfaktor | Mini-Split |
| Spesiale kenmerke | Easy to Install (by professional), Washable filters |
| Kleur | Wit |
| Voltage | 115 Volt |
| Ingesluit komponente | Remote Control, Window Kit (likely refers to installation kit components) |
| Vloeroppervlaktedekking | 450 vierkante voet |
| Koelmiddel | R-32 |
| Kragbron | Elektries met koord |
| Operating Temperature (Cool) | Tot 122°F |
| Operating Temperature (Heat) | As low as -4°F |
9. Waarborg en Ondersteuning