TOOLTOP ET120M

TOOLTOP ET120M 120MHz Handheld Digital Oscilloscope User Manual

Model: ET120M | Brand: TOOLTOP

1. Inleiding

This manual provides detailed instructions for the safe and effective operation of your TOOLTOP ET120M 120MHz Handheld Digital Oscilloscope. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.

2. Veiligheidsinligting

Always observe the following safety precautions when using the ET120M oscilloscope:

  • Moenie die toestel in nat of damp voorwaardes.
  • Ensure the device is powered off before connecting or disconnecting probes.
  • Gebruik slegs die voorsiene bykomstighede of goedgekeurde vervangings.
  • Do not attempt to open or modify the device; refer all servicing to qualified personnel.
  • Hou die toestel weg van sterk elektromagnetiese velde.

3. Pakketinhoud

Verifieer dat al die items wat hieronder gelys word, in u pakket teenwoordig is:

  • TOOLTOP ET120M Handheld Digital Oscilloscope
  • 100MHz Oscilloscope Probe
  • USB-laaikabel
  • Gebruikershandleiding
  • Doek sak
Contents of the TOOLTOP ET120M package, including the oscilloscope, probe, charging cable, user manual, and cloth bag.

Figuur 3.1: Pakketinhoud

4. Produk verbyview

4.1. Toestelkenmerke

The TOOLTOP ET120M is a compact and portable handheld digital oscilloscope designed for various electrical testing and repair applications. Key features include:

  • 120MHz analog bandwidth and 500MS/s real-time sampling koers.
  • 2.4-inch 320x240 clear color LCD screen.
  • Integrated square wave signal output (1kHz, 10KHz, 100KHz, 1MHz).
  • 12 types of automatic parameter measurements (Vpp, Vrms, Vavg, Vp, Vmax, Vmin, F, T, T+, T-, Du+, Du-).
  • Three scan modes: Auto, Normal, and Single.
  • Ability to store 2500 DSO waveforms with thumbnail browsing.
  • Built-in rechargeable lithium battery for up to 6 hours of continuous use.
  • Durable design with a silicone protective cover.
Diagram highlighting the eight key advantages of the ET120M oscilloscope, including 120MHz bandwidth, auto waveform capture, three scan modes, parameter settings, square wave output, 2500 waveform save, lithium battery, and color screen.

Figuur 4.1: Belangrike kenmerke oorview

4.2. Komponentidentifikasie

Familiarize yourself with the main components and controls of the ET120M oscilloscope:

Voorkant view of the TOOLTOP ET120M handheld digital oscilloscope, showing the screen, control buttons, and input port.

Figuur 4.2: Voorkant View of ET120M Oscilloscope

  • Vertoon skerm: 2.4-inch LCD for waveform display and menu navigation.
  • Input BNC Connector: For connecting the oscilloscope probe.
  • Beheerknoppies: Including MENU, F1, F2, SAVE, AC/DC, 1X/10X, 50%, TRIG, EDGE, STOP, AUTO, and directional/OK buttons for navigation and settings adjustment.
  • USB-poort: Vir die laai van die toestel.

5. Opstelling

5.1. Aanvanklike laai

Before first use, fully charge the built-in lithium battery using the provided USB charging cable and a standard USB power adapter (not included). The charging indicator will show the charging status.

5.2. Sondeverbinding

Connect the oscilloscope probe to the BNC input connector on the top of the device. Ensure the connection is secure. Set the probe attenuation switch (if applicable) to the desired setting (e.g., 1X or 10X) and match this setting on the oscilloscope via the 1X/10X button.

6. Bedryfsinstruksies

6.1. Skakel aan/af

Press and hold the power button (usually located on the side or top) to turn the device on or off.

6.2. Basic Waveform Acquisition

After powering on, connect the probe to the circuit under test. The oscilloscope will display the waveform. Use the directional buttons to navigate menus and adjust settings.

6.3. Waveform Acquisition Modes

The ET120M supports three scan modes:

  • Outo: Automatically adjusts time base and vertical amplitude for a stable waveform display. Press the AUTO button for one-key waveform adaptation.
  • Normaal: Displays a waveform only when a trigger condition is met.
  • Enkellopend: Captures and displays a single waveform when a trigger condition is met, then stops.
Screenshots demonstrating the auto oscilloscope function, showing how the waveform adapts automatically when the AUTO button is pressed.

Figure 6.1: Auto Waveform Adaptation

6.4. Parameter Measurement

The device can automatically measure 12 different waveform parameters. Access these measurements through the menu system. Parameters include Peak-to-Peak Voltage (Vpp), Root Mean Square Voltage (Vrms), Average Voltage (Vavg), Peak Voltage (Vp), Maximum Voltage (Vmax), Minimum Voltage (Vmin), Frequency (F), Period (T), Positive Pulse Width (T+), Negative Pulse Width (T-), Positive Duty Cycle (Du+), and Negative Duty Cycle (Du-).

Oscilloscope screen displaying various waveform measurement parameters like Vpp, Vrms, Vavg, F, T, and duty cycle.

Figure 6.2: Automatic Measurement Functions

6.5. Square Wave Signal Output

The ET120M can generate square wave signals at specific frequencies. Navigate to the signal output function in the menu to select between 1kHz, 10KHz, 100KHz, and 1MHz output frequencies. This feature is useful for testing circuits.

Oscilloscope displaying a square wave output, with menu options for selecting output frequencies (1kHz, 10kHz, 100kHz, 1MHz).

Figure 6.3: Square Wave Signal Output Function

6.6. Waveform Storage and Recall

The device can store up to 2500 DSO waveforms. Use the SPAAR button to store the current waveform. Stored waveforms can be browsed via thumbnails for easy recall and analysis.

Oscilloscope screen showing stored waveforms and options to navigate through them (Back, Pre, Next).

Figure 6.4: Waveform Storage and Browsing

6.7. Adjusting Waveform Parameters

You can manually adjust various waveform display parameters to fine-tune your measurements:

  • Tydbasis: Adjusts the horizontal scale (time per division).
  • Amplitude (Vertical Sensitivity): Adjusts the vertical scale (volts per division).
  • Trigger Slope: Sets the trigger to rising or falling edge.
  • Snellervlak: Stel die voltage level at which the waveform is triggered.
Oscilloscope screen showing a waveform with 120MHz bandwidth and 500MS/s sampling rate, along with menu options for adjusting voltage and time base settings.

Figure 6.5: Adjusting Waveform Display Parameters

7. Onderhoud

7.1. Skoonmaak

Om die toestel skoon te maak, gebruik 'n sagte, droë lap. Vir hardnekkige vuiligheid, gebruik 'n effens droë lap.amp cloth with mild detergent can be used, ensuring no liquid enters the device. Do not use abrasive cleaners or solvents.

7.2. Berging

When not in use for extended periods, store the oscilloscope in a cool, dry place, away from direct sunlight and extreme temperatures. It is recommended to store it in the provided cloth bag to protect it from dust and scratches.

7.3. Batteryversorging

To prolong battery life, avoid fully discharging the battery frequently. If storing for a long time, charge the battery to approximately 50% every few months.

8. Probleemoplossing

If you encounter issues with your ET120M oscilloscope, refer to the following common problems and solutions:

  • Toestel skakel nie aan nie: Ensure the battery is charged. Connect the USB charging cable and try again.
  • No waveform displayed: Check probe connection. Ensure the probe is properly connected to the circuit under test. Adjust vertical sensitivity and time base settings. Try the AUTO function.
  • Unstable waveform: Adjust the trigger level and trigger slope. Ensure the trigger mode is appropriate for the signal.
  • Onakkurate metings: Verify probe attenuation setting (1X/10X) matches the device setting. Perform a probe compensation if necessary (refer to advanced operation in a full manual).

For persistent issues, contact TOOLTOP customer support.

9. Spesifikasies

9.1. Algemene spesifikasies

Vertoon320x240 LCD screen
Vertoon area50 mm x 40 mm
AgterligWhite, brightness adjustable
Impedansiex1: 1MΩ / x10: 10MΩ
Battery18650 lithium battery (built-in)
Outo-afskakelingGeen operasie vir 15 minute nie
Waveform Storage2500 DSO waveforms
Grootte124 mm x 80 mm x 35 mm
Bedryfsvoorwaardes0°C ~ +40°C; <75%RH
Bergingsvoorwaardes-10°C ~ +60°C; <90%RH

9.2. Ossilloskoopspesifikasies

Analoog bandwydte120 MHz
Maximum Real-time Sampling Koers500MSps
Vertikale resolusie8 stukkies
Vertikale Akkuraatheid± (5% + 0.2 div)
Auto Zero ReferenceTydens GS-meting
Sneller vlak±3.8div (0.1div per step)
Trigger Position±6div (0.1div per step)
Cursor FunctionΔV, Δt, 1/Δt
Nie-lineariteit±1 bits
KoppelmetodeDC/AC
Division Vertical±3.8 Horizontal: 12
Tydbasisreeks6ns / div ~ 50s / div
Tydbasis Akkuraatheid±(0.01%+0.1div)
Scan afAuto/Single/Normal
SnellerhellingRising / Falling
Rekord Lengte12 div
OutokonfigurasieAutomatically set time base and vertical amplitude
Automatic Measurement FunctionsVpp, Vrms, Vavg, Vp, Vmax, Vmin, F, T, T+, T-, Du+, Du-
Vertical Sensitivity Rangex1: 50mV/div ~ 10V/div; x10: 500mV/div ~ 100V/div

10. Waarborg en Ondersteuning

For warranty information or technical support, please refer to the documentation provided with your purchase or contact TOOLTOP customer service directly. Keep your purchase receipt as proof of purchase.