This manual provides detailed instructions for the installation, operation, and maintenance of the RAB Lighting B17 LED Bollard Light. This outdoor luminaire features field-adjustable wattage and selectable color temperature (CCT), designed for various outdoor applications.

Sleutel kenmerke sluit in:

  • Energy-efficient LED with a 50,000-hour lifespan.
  • Verstelbare wattage: 24W, 19W, or 14W.
  • Selectable CCT: 3000K (Warm White), 4000K (Neutral White), or 5000K (Cool White).
  • 0-10V dimming capability.
  • UL Gelys vir nat plekke.
  • Durable metal construction with a glass shade.
RAB Lighting B17 LED Bollard Light

Figure 1: RAB Lighting B17 LED Bollard Light (Model B17D shown).

2. Veiligheidsinligting

WAARSKUWING: Risk of electric shock. Disconnect power before installation or servicing. Installation should be performed by a qualified electrician in accordance with all applicable national and local electrical codes.

  • Verseker die toevoer voltage is correct for the fixture.
  • Do not handle live components.
  • Dra toepaslike persoonlike beskermende toerusting (PPE).
  • This fixture is suitable for wet locations. Ensure all connections are properly sealed to prevent water ingress.
  • Moenie die toebehore wysig nie. Enige wysigings kan die waarborg ongeldig maak en veiligheidsgevare skep.

3. Pakketinhoud

Verifieer dat alle komponente teenwoordig is voordat u met die installasie begin:

  • B17 LED Bollard Light Fixture
  • On-Off Switch (Included Components)
  • Installation Hardware (e.g., mounting bolts, gaskets) - (Assumed, not explicitly listed but typical for such products)
  • Instructiehandleiding (hierdie dokument)

4. Opstelling en installering

Follow these steps for proper installation of the B17 LED Bollard Light:

  1. Berei die installasiewerf voor: Ensure the mounting surface is stable and level. Run electrical conduit and wiring to the desired location according to local codes.
  2. Ontkoppel krag: Skakel die krag by die stroombreker af voordat u enige elektriese werk begin.
  3. Mount the Bollard: Secure the bollard base to the mounting surface using appropriate hardware. Ensure a watertight seal if required by local codes.
  4. Maak elektriese verbindings: Connect the fixture's wires to the supply wires. Follow standard wiring practices:
    • Black to Line (L)
    • White to Neutral (N)
    • Green/Ground to Ground (G)
    • Purple to Dimming (+) (for 0-10V dimming)
    • Gray to Dimming (-) (for 0-10V dimming)
    Maak seker dat alle verbindings veilig en geïsoleer is.
  5. Kies Wattage en CCT: Before closing the fixture, adjust the wattage and CCT switches located inside the fixture head. Refer to Section 5 for details.
  6. Secure the Fixture Head: Attach the fixture head to the bollard body, ensuring all seals are properly seated to maintain the wet location rating.
  7. Herstel krag: Turn on power at the circuit breaker and test the light.
UL Listed and Wet Location Rated symbols

Figure 2: The B17 Bollard Light is UL Listed and rated for wet locations, ensuring durability in outdoor environments.

5. Bedryfsinstruksies

5.1. Field-Adjustable Wattage

The B17 bollard light allows you to select the desired wattage output to optimize brightness and energy consumption. A switch located inside the fixture head enables selection between 24W, 19W, and 14W.

  • 24W: Maksimum helderheid.
  • 19W: Medium brightness, reduced energy use.
  • 14W: Lower brightness, maximum energy savings.

Om aan te pas: Disconnect power. Open the fixture head. Locate the wattage selection switch and move it to the desired setting. Close the fixture head and restore power.

5.2. Selectable Color Temperature (CCT)

The fixture offers three color temperature options to suit different aesthetic preferences and applications. A separate switch inside the fixture head allows selection between 3000K, 4000K, and 5000K.

  • 3000K: Warm White, ideal for creating a cozy and inviting atmosphere.
  • 4000K: Neutral White, suitable for general illumination and task lighting.
  • 5000K: Cool White, provides bright, crisp light, often used for security or modern aesthetics.

Om aan te pas: Disconnect power. Open the fixture head. Locate the CCT selection switch and move it to the desired setting. Close the fixture head and restore power.

Image showing 14W, 19W, 24W wattage options and 3000K, 4000K, 5000K CCT options for the bollard light

Figure 3: Visual representation of adjustable wattage and selectable CCT settings.

5.3. 0-10V Verduistering

The B17 bollard light is compatible with 0-10V dimming systems. Connect the purple and gray dimming wires to a compatible 0-10V dimmer control. This allows for smooth adjustment of light output from 100% down to 10% (or lower, depending on dimmer specifications).

Ensure the dimmer is rated for LED loads and is compatible with 0-10V dimming protocols.

6. Onderhoud

The B17 LED Bollard Light is designed for minimal maintenance due to its long LED lifespan of 50,000 hours.

  • Skoonmaak: Maak die buitekant van die toestel gereeld skoon met 'n sagte, damp cloth to remove dirt and debris. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
  • Inspeksie: Annually inspect the fixture for any signs of damage, loose connections, or wear. Ensure all seals remain intact to maintain weather resistance.
  • LED vervanging: LEDs are integrated and not user-replaceable. The long lifespan minimizes the need for replacement.
Image indicating a 50,000-hour lifespan for the LED bollard light

Figure 4: The B17 LED Bollard Light offers a long 50,000-hour operational lifespan.

7. Probleemoplossing

ProbleemMoontlike oorsaakOplossing
Lig skakel nie aan nie.Geen kragtoevoer.
Los bedrading konneksie.
Verkeerde wattage/CCT setting.
Check circuit breaker. Ensure power is on.
Verifieer dat alle draadverbindings stewig is (skakel eers die krag af).
Bevestig wattage/CCT switches are set correctly.
Lig flikker of dof onverwags.Onversoenbare dimmer.
Loose dimming wire connection.
Voltage skommelinge.
Ensure 0-10V dimmer is compatible with LED loads.
Check purple and gray dimming wire connections.
Consult an electrician to check power supply stability.
Liguitset is te laag/hoog.Verkeerde wattage instelling.Pas die wat aantage selection switch inside the fixture head (power off first).
Light color is not desired.Verkeerde CCT-instelling.Adjust the CCT selection switch inside the fixture head (power off first).

8. Spesifikasies

KenmerkDetail
Model NaamB17
HandelsmerkRAB Beligting
WattageField-Adjustable: 24W / 19W / 14W
Kleurtemperatuur (CCT)Selectable: 3000K / 4000K / 5000K
Verduistering0-10V Dimbaar
Lewensduur50,000 uur
MateriaalMetal body, Glass shade
OmgewingsgraderingUL Listed for Wet Locations
Ingesluit komponenteAan-uit skakelaar
UPC192552028424