1. Inleiding
This manual provides instructions for the proper use and maintenance of the Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, model 4710-1205. This electronic depth gage is designed for precise depth measurements in various industrial and scientific applications. It features a digital display for clear readings and is constructed for durability and accuracy.

Image 1.1: The Dasqua 7 Piece 0-16-Inch Electronic Depth Gage Set, showing the main unit and various measurement rods.
2. Pakketinhoud
Verifieer dat alle komponente in die pakket teenwoordig is:
- Electronic Depth Gage Unit
- Set of Measurement Rods (7 pieces)
- Bergkas
- Warranty Letter

Image 2.1: The complete Dasqua Electronic Depth Gage Set, including the main unit, measurement rods, and storage case.
3. Sleutel kenmerke
- Resolusie: 0.0005-inch / 0.01mm for precise measurements.
- Standaardvoldoening: Manufactured in accordance with DIN863 standards.
- Spil: Hardened, ground, and lapped for enhanced accuracy.
- Veelsydigheid: Designed to accommodate a broad range of measurement applications.
- Vertoon: Large, digital display for clear and quick readings.
- Konstruksie: Hardened stainless steel base and rods resist wear, ensuring durability and consistent accuracy.
- Nul-terugstel: Ability to reset to zero at any position for comparative depth measurements.
4. Opstelinstruksies
4.1. Battery Installasie
The electronic depth gage typically uses a CR2032 lithium coin cell battery. To install or replace the battery:
- Locate the battery compartment cover on the back of the digital display unit.
- Use a small screwdriver or coin to open the cover.
- Plaas 'n nuwe CR2032-battery met die positiewe (+) kant na bo.
- Plaas die batterykompartement se deksel veilig terug.
4.2. Attaching Measurement Rods
Select the appropriate measurement rod for the desired depth range. The set includes rods of various lengths.
- Identify the threaded end of the measurement rod.
- Carefully screw the rod into the threaded hole at the bottom of the depth gage's base until it is finger-tight. Do not overtighten.
- Ensure the rod is securely attached and straight.

Image 4.1: The electronic depth gage with a measurement rod properly attached to its base.

Image 4.2: A selection of the hardened stainless steel measurement rods provided with the depth gage set.
5. Bedryfsinstruksies
5.1. Skakel aan/af
- Druk die AAN/AF knoppie om die toestel aan te skakel.
- Druk die AAN/AF button again to power off the device.
5.2. Unit Conversion (Inch/Millimeter)
- Druk die mm/in button to switch between millimeter (mm) and inch (in) units. The selected unit will be displayed on the screen.
5.3. Nulstelling
The zero-reset function allows for comparative measurements or setting a reference point.
- Place the depth gage on a flat, stable reference surface, ensuring the measurement rod is fully retracted or resting on the surface.
- Druk die NUL button. The display will show '0.000' or '0.00'.
5.4. Neem 'n meting
- Ensure the depth gage is zeroed on a reference surface.
- Place the base of the depth gage firmly on the surface from which the depth is to be measured.
- Lower the measurement rod into the hole or recess until its tip contacts the bottom.
- Read the measurement directly from the digital display.
5.5. Hou-funksie
- Druk die HOU knoppie om die huidige lesing op die skerm te vries.
- Druk die HOU knoppie weer om die lesing vry te stel en terug te keer na regstreekse meting.

Beeld 5.1: Gedetailleerd view of the digital display, showing the ON/OFF, mm/in, HOLD, and ZERO buttons.
6. Onderhoud
6.1. Skoonmaak
- Wipe the depth gage and rods with a clean, dry, lint-free cloth after each use.
- Vir hardnekkige vuiligheid, gebruik 'n lap wat liggies gevryf word.ampened with isopropyl alcohol. Avoid harsh chemicals or solvents.
- Ensure no liquid enters the electronic components.
6.2. Berging
- Store the depth gage in its protective case when not in use.
- Hou die toestel in 'n droë omgewing, weg van direkte sonlig, uiterste temperature en hoë humiditeit.
- Indien dit vir 'n lang tydperk gestoor word, verwyder die battery om lekkasie te voorkom.
6.3. Battery vervanging
Replace the battery when the display becomes dim or erratic. Refer to Section 4.1 for battery installation instructions.
7. Probleemoplossing
- Skerm is leeg of dof:
Check battery installation. Replace the battery if necessary. Ensure the device is powered on. - Onakkurate lesings:
Ensure the depth gage is properly zeroed on a flat reference surface. Clean the measurement rod and base to remove any debris. Verify the measurement rod is securely attached. - Knoppe reageer nie:
Check battery level. If the issue persists after battery replacement, contact customer support.
8. Produkspesifikasies
| Spesifikasie | Detail |
|---|---|
| Modelnommer | 4710-1205 |
| Meetreeks | 0-16 duim / 0-400 mm |
| Resolusie | 0.0005 duim / 0.01 mm |
| Akkuraatheid | 0.0015 duim / 0.03 mm |
| Materiaal | Hardened Stainless Steel |
| Kragbron | CR2032 Battery (typical) |
| Pakket afmetings | 9 x 5 x 2 duim |
| Item gewig | 12.8 onse |

Image 8.1: Detailed specifications and dimensional diagram for the Dasqua 0-16 inch Electronic Depth Gage Set.
9. Waarborg en Ondersteuning
This product is supplied with a warranty letter. For specific warranty terms and conditions, please refer to the documentation included in your package. For technical support, service, or inquiries regarding your Dasqua 4710-1205 Electronic Depth Gage Set, please contact the manufacturer directly through their official webwebwerf of kliëntedienskanale.