Sper Wetenskaplik 850015

Sper Scientific 850015 Grafiese Vertoon Klankmeter Gebruikershandleiding

Model: 850015

1. Inleiding

This manual provides comprehensive instructions for the operation and maintenance of the Sper Scientific 850015 Graphic Display Sound Meter. This precision instrument is designed for accurate sound level measurements and complies with industry standards ANSI S1.4 Type 2 and IEC 61672-1 Class 2.

The device features a clear graphic display, selectable A and C decibel frequency weighting scales, minimum/maximum value tracking, and adjustable fast or slow response times. It also includes AC and DC output capabilities for external recording or analysis.

Sper Scientific 850015 Graphic Display Sound Meter

Figure 1: Sper Scientific 850015 Graphic Display Sound Meter. This image shows the front view of the sound meter, highlighting its display and control buttons.

2. Pakketinhoud

Nadat u die pakkie oopgemaak het, maak seker dat al die items wat hieronder gelys word, teenwoordig en in 'n goeie toestand is:

  • Sper Scientific 850015 Graphic Display Sound Meter
  • Voorruit
  • 9V Battery
  • Instructiehandleiding (hierdie dokument)
  • Foam-lined Hard Shell Carrying Case
Sper Scientific 850015 Sound Meter in carrying case with accessories

Figure 2: The Sper Scientific 850015 Sound Meter shown within its protective foam-lined hard shell carrying case, alongside the included 9V battery and instruction manual.

3. Opstelling en batteryinstallasie

The Sper Scientific 850015 comes with a 9V battery included. Follow these steps to install or replace the battery:

  1. Vind die batteryklepdeksel aan die agterkant van die toestel.
  2. Skuif of knip die deksel los om die kompartement oop te maak.
  3. Koppel die 9V-battery aan die batteryklem en maak seker dat die polariteit korrek is.
  4. Place the battery into the compartment and replace the cover, securing it firmly.
  5. Attach the windscreen to the microphone at the top of the meter. This helps reduce wind noise during measurements.

4. Bedryfsinstruksies

Familiarize yourself with the device's controls and display before operation.

Sper Scientific 850015 Sound Meter held in hand

Figure 3: The Sper Scientific 850015 Sound Meter being held, demonstrating its ergonomic design and ease of use.

4.1. Skakel aan/af

  • Druk die Krag button (usually marked with "I" or a power symbol) to turn the meter on.
  • Druk en hou die Krag button for a few seconds to turn the meter off.
  • The meter features an auto-power-off function to conserve battery life.

4.2. A/C Weighting Selection

  • Druk die A/C button to toggle between A-weighting and C-weighting.
  • A-gewig (dBA) is commonly used for environmental noise measurements and approximates the human ear's response.
  • C-gewig (dBC) provides a flatter response, suitable for measuring peak sound levels or noise from machinery.

4.3. Fast/Slow Response Time

  • Druk die VINNIG/STADIG button to select the desired response time.
  • VINNIG response (125 ms) is suitable for capturing rapidly changing noise levels.
  • STADIG response (1 second) provides an averaged reading for more stable noise sources.

4.4. MIN/MAX Function

  • Druk die MIN / MAX button to activate the minimum/maximum hold function.
  • The display will show the highest (MAX) or lowest (MIN) sound level recorded since the function was activated.
  • Press the button again to cycle through MAX, MIN, and normal measurement modes.

4.5. AC/DC Output

The meter provides AC and DC output jacks for connecting to external devices such as chart recorders, data loggers, or sound analysis equipment. Refer to the specifications section for output voltage besonderhede.

5. Maintenance and Calibration

5.1. Skoonmaak

To ensure optimal performance and longevity, keep the meter clean. Wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the microphone is free from dust and debris.

5.2. Battery vervanging

When the low battery indicator appears on the display, replace the 9V battery as described in the "Setup and Battery Installation" section. Always dispose of used batteries responsibly.

5.3. Kalibrasie

For applications requiring high accuracy or regulatory compliance, periodic calibration is recommended. The Sper Scientific 850015 can be calibrated in compliance with OSHA standards using an optional Acoustical Calibrator (Model 850016). A N.I.S.T. traceable certificate of calibration is also available from Sper Scientific.

6. Probleemoplossing

If you encounter issues with your Sper Scientific 850015, refer to the following common problems and solutions:

ProbleemMoontlike oorsaakOplossing
Toestel skakel nie aan nie.Dooie of onbehoorlik geïnstalleerde battery.Check battery installation; replace with a fresh 9V battery.
Onakkurate of wisselende lesings.Microphone obstructed, strong wind, or meter needs calibration.Ensure windscreen is properly installed and microphone is clear. Avoid strong air currents. Consider calibration if readings remain inconsistent.
Display shows "LO BAT".Battery is laag.Vervang die 9V-battery onmiddellik.
No response from buttons.Device frozen or battery issue.Remove and reinsert the battery to reset the device. If problem persists, replace battery.

7. Spesifikasies

The following table details the technical specifications for the Sper Scientific 850015 Graphic Display Sound Meter:

ParameterWaarde
Meetreeks30 to 130 dB (A & C scales)
Resolusie0.1 dB
Akkuraatheid±1.4 dB (ref 94 dB @ 1KHz)
Frekwensie-gewigA en C
Reaksie TydFast (125 ms) / Slow (1 sec)
UitsetAC en DC
Outomatiese afskakelingJa
Lae battery aanwyserJa
Voldoening aan standaardeANSI S1.4 Type 2, IEC 61672-1 Class 2
Afmetings10¼" × 2¼" × 1" (258 × 55 × 25 mm)
Gewig6.5 onse (185 g)
Kragbron1 x 9V battery (ingesluit)
Specifications table for Sper Scientific 850015

Figure 4: A visual representation of key specifications for the Sper Scientific 850015, including range, resolution, and accuracy.

8. Waarborg en Ondersteuning

For information regarding product warranty, technical support, or service, please contact Sper Scientific directly. Their official website or the contact information provided with your purchase documentation will have the most up-to-date details.

Vervaardiger: Sper Scientific
Webwebwerf: Sper Wetenskaplike Winkel op Amazon (vir algemene produkinligting)

© 2025 Sper Scientific. Alle regte voorbehou.

Ask a question about this manual