TRACEABLE AO-94460-07

Traceable Excursion-Trac Data Logging Thermometer User Manual

Model: AO-94460-07

1. Inleiding

The Traceable Excursion-Trac Data Logging Thermometer is designed for precise and reliable temperature monitoring and data logging. This device is ideal for applications requiring continuous temperature tracking and historical data retrieval. It features a clear LCD display, alarm functions, and the ability to log a significant number of temperature observations.

Traceable Excursion-Trac Data Logging Thermometer with bottle probe and USB drive.

Voorkant view of the Traceable Excursion-Trac thermometer, showing the main display, control buttons, connected bottle probe, and a USB flash drive for data transfer.

2. Opstelling

2.1 Uitpak

Carefully unpack all components. The package should contain:

  • Traceable Excursion-Trac Data Logging Thermometer unit
  • 1 Bottle Probe
  • 2 AAA-batterye
  • Instructiehandleiding (hierdie dokument)

2.2 Battery installasie

  1. Vind die battery kompartement op die agterkant van die termometer.
  2. Maak die kompartement se deksel oop.
  3. Plaas twee (2) AAA-batterye in en maak seker dat die polariteit (+/-) korrek is.
  4. Close the battery compartment cover securely. The device will power on automatically.

2.3 Sondeverbinding

Connect the bottle probe cable to the designated probe input port (labeled P1 or P2) on the side of the thermometer unit. Ensure the connection is firm.

Terug view of Traceable Excursion-Trac thermometer with kickstand.

Agter view of the thermometer, illustrating the integrated kickstand for desktop placement and wall-mount slot.

3. Bedryfsinstruksies

3.1 Krag aan/af

The device powers on automatically upon battery installation. To turn off the device, remove the batteries. For temporary power saving, some models may have an ON/OFF switch for the alarm or display backlight, but the main unit remains active for logging.

3.2 Vertoon oorview

Die LCD-skerm wys verskeie inligting:

  • Huidige temperatuur: The primary reading from the connected probe(s).
  • MIN / MAX: Minimum and maximum temperatures recorded since the last reset.
  • MEM: Indicates memory status or data logging activity.
  • Alarm: Indicates alarm status (active, triggered).
  • DATUM TYD: Current date and time for logged events.
Traceable Excursion-Trac thermometer displaying current date and time.

The thermometer display showing the current date and time, indicating its time-keeping functionality for logged data.

3.3 Unit Selection (°C/°F)

Druk die EENHEDE button to toggle between Celsius (°C) and Fahrenheit (°F) temperature scales.

3.4 Viewing Min/Max/Date/Time

Druk die MIN/MAX/ALARM-DATE/TIME button to cycle through the minimum temperature, maximum temperature, and current date/time displays. The display will show the recorded minimum and maximum temperatures since the last reset.

3.5 Alarm Funksie

The thermometer features programmable high and low alarms. When the temperature exceeds or falls below the set limits, an audible and visual alarm will activate.

  1. Stel alarms: Gebruik die SELECT/ADVANCE en ALARM DATE SET buttons to navigate and adjust the high and low temperature thresholds. Refer to the on-screen prompts for specific steps.
  2. Alarm aan/af: Gebruik die ALARM AAN / AF switch to enable or disable the alarm function.
  3. Stil alarm: Druk die STIL ALARM button to temporarily mute an active alarm.
  4. Event Display: Die EVENT DISPLAY button allows viewing of recorded alarm events. The device can store up to 10 individual alarm events.

3.6 Data Logging and Retrieval

The Excursion-Trac thermometer automatically logs temperature data. It can store up to 525,600 temperature observations. To retrieve logged data:

  1. Connect the thermometer to a computer using a standard USB cable (not always included, check package contents).
  2. The device should appear as a removable storage device.
  3. Access the logged data files (typically in a CSV or similar format) from the device's storage.
  4. Kopieer die files to your computer for analysis.
Kant view of Traceable Excursion-Trac thermometer showing USB port.

Kant view of the thermometer, clearly showing the USB port for data transfer and the power input.

4. Onderhoud

4.1 Batteryvervanging

When the low battery indicator appears on the display, replace the two AAA batteries immediately. Ensure new batteries are inserted with correct polarity.

4.2 Skoonmaak

Vee die termometereenheid en probes af met 'n sagte, damp cloth. Do not use abrasive cleaners or immerse the main unit in liquids. The bottle probe is designed for use in various environments, including freezers.

4.3 Kalibrasie

The Traceable Excursion-Trac thermometer is supplied with an individually calibrated and certified NIST-traceable certificate. For continued accuracy and compliance, periodic recalibration is recommended according to your facility's protocols or regulatory requirements.

5. Probleemoplossing

  • "Battery Low" Message: Replace the two AAA batteries immediately. Ensure new batteries are inserted with correct polarity.
  • Onakkurate lesings: Verify that the probe is securely connected to the unit. Ensure the probe is correctly positioned within the environment being monitored. Check for any visible damage to the probe cable or sensor.
  • Data Download Issues: Ensure the USB cable is properly connected to both the thermometer and the computer. Try a different USB port or cable. If the device does not appear as a removable drive, consult the manufacturer's support for specific driver or software requirements.
  • Geen skerm: Check battery installation and ensure batteries are not depleted. If the issue persists after replacing batteries, contact customer support.

6. Spesifikasies

Traceable Excursion-Trac thermometer with dimensions indicated.

An illustration of the thermometer with its physical dimensions and temperature range.

KenmerkDetail
ModelnommerAO-94460-07
Akkuraatheid±0.25°C
Temperatuurreeks-50°C tot 70°C (-58°F tot 158°F)
Temperatuurresolusie0.01°
Soort ondersoek1 Bottle Probe
DataregistrasiekapasiteitUp to 525,600 temperature observations
Tipe vertoonLCD, 1/2"H digits
KonnektiwiteitUSB
Kragbron2 x AAA-batterye
MateriaalPlastiek
Afmetings (H x B x D)10.79 cm x 6.98 cm x 1.9 cm (ongeveer 4.25 duim x 2.75 duim x 0.75 duim)
Spesiale kenmerkeHigh Accuracy, Min/Max Memory, Alarm Function, 3m Micro-Thin Cable, Integrated Stand, Wall Mount, Magnetic Strip

7. Waarborg en Ondersteuning

For technical assistance, warranty claims, or further information regarding your Traceable Excursion-Trac Data Logging Thermometer, please contact your supplier or the manufacturer directly. Refer to your purchase documentation for specific warranty terms and contact details.