1. Inleiding
This manual provides comprehensive instructions for the installation, operation, and maintenance of your DAUZ WK-004 Digital Temperature Controller. Please read this manual carefully before use to ensure proper functionality and safety. Keep this manual for future reference.
2. Produk verbyview en kenmerke
The DAUZ WK-004 is a multifunctional intelligent 4-way digital thermostat regulator designed for precise temperature control in various applications, including greenhouses, animal husbandry, boiler water pumps, and flower cultivation. It features robust construction and advanced functionalities for reliable performance.
- 4-Way Independent Control: The controller supports 4 independent outputs, each with separate heating and cooling settings.
- High Precision Display: Features a precise digital display with accuracy up to 0.1℃.
- Alarmfunksionaliteit: Includes high and low temperature overshoot alarm functions to prevent damage and ensure optimal conditions.
- Duursame konstruksie: Made from non-toxic, shock-resistant, heat-resistant, and low-temperature resistant ABS material.
- Waterdigte sonde: Equipped with a waterproof NTC probe for reliable temperature sensing in various environments.
- Voltage Fluctuation Protection: Designed with accessories to prevent damage from voltage skommelinge.

Figuur 2.1: Voorkant view of the DAUZ WK-004 Digital Temperature Controller, showing the digital display and control buttons.
3. Spesifikasies
| Kenmerk | Spesifikasie |
|---|---|
| Item Tipe | Digitale temperatuurbeheerder |
| Materiaal | ABS |
| Voltage | 110-230 V |
| Invoer | NTC-ondersoek |
| Akkuraatheid | ±0.5% FS |
| Error Correction Range | -9 to +9 ℃ (software correction available) |
| Vertoon reeks | Process value, deviation value: -9.9 ~ 99.9 ℃ |
| Beheer uitset | 4 independent relay controls, independent temperature alarm output |
| Opening Grootte | Approx. 157 x 76 mm / 6.18 x 2.99 inches |
| Item Modelnommer | DAUZ1ubydfx53e-11 |
| Pakket sluit in | 1 x Temperature Controller, 1 x NTC Probe (10m) |

Figure 3.1: The DAUZ WK-004 controller shown with its included 10-meter NTC waterproof temperature probe.
4. Opstelling en installering
The DAUZ WK-004 controller is designed for direct installation or integration into industrial control equipment panels. Ensure all power is disconnected before proceeding with installation.
- Montering: Install the controller into a panel opening of approximately 157 x 76 mm. Secure it using the provided clips or mounting hardware.
- Bedrading: Connect the power supply (110-230V) to the designated terminals. Connect the NTC temperature probe to the appropriate input terminals. Connect your heating and cooling devices to the 4 independent relay output terminals as required for your application. Refer to the wiring diagram on the back of the unit for precise connections.
- Sondeplasing: Position the waterproof NTC probe in the environment where temperature measurement and control are needed. Ensure the probe is securely placed and not exposed to direct physical damage.
- Aanvanklike kragopwekking: After all connections are secure, apply power to the unit. The digital display should illuminate.

Figuur 4.1: Agter view of the controller, illustrating the various wiring terminals for power, NTC probe, and the four independent relay outputs.
5. Bedryfsinstruksies
The WK-004 controller allows for independent temperature and time settings for each of its four channels.
- Krag aan/af: The unit powers on automatically when connected to a power source.
- Temperatuurinstelling: Press the 'Temperature Setting' button to enter temperature adjustment mode. Use the 'Add' and 'Subtract' buttons to set the desired temperature for the active channel. Repeat for each channel as needed.
- Tyd instelling: Press the 'Time Setting' button to enter time adjustment mode. Use the 'Add' and 'Subtract' buttons to set the desired operational time or delay for the active channel.
- Verhitting/Verkoelingsmodus: Each channel can be configured for independent heating or cooling operation. Refer to the on-screen indicators (e.g., A0 for heating, A1 for cooling) and the specific programming instructions provided with the device for detailed mode selection.
- Alarmdrempels: Set high and low temperature alarm thresholds to trigger alerts if the temperature exceeds or falls below the set limits. Consult the device's programming menu for setting these values.
- Fout regstelling: If temperature readings appear inaccurate, use the software error correction feature (range -9 to +9 ℃) to calibrate the sensor.

Figuur 5.1: Hoekig view of the controller's front panel, highlighting the digital displays for temperature and time, along with the 'Temperature Setting' and 'Time Setting' buttons.
6. Onderhoud
Regular maintenance ensures the longevity and accurate operation of your DAUZ WK-004 Digital Temperature Controller.
- Skoonmaak: Wipe the controller's surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Sonde-inspeksie: Periodically inspect the NTC probe for any signs of damage or corrosion. Ensure it is clean and free from debris that could affect its accuracy.
- Verbindingskontrole: Regularly check all wiring connections to ensure they are secure and free from loose contacts.
- Omgewingstoestande: Ensure the controller is operated within its specified environmental conditions to prevent damage. The ABS material is resistant to heat and low temperatures, but extreme conditions should be avoided.
7. Probleemoplossing
If you encounter issues with your DAUZ WK-004 controller, refer to the following common troubleshooting steps:
- Geen skerm/krag: Kontroleer die kragtoevoerverbinding en maak seker die volumetage is within the 110-230V range. Verify that the power outlet is functional.
- Verkeerde temperatuurlesing: Ensure the NTC probe is correctly connected and fully inserted. Check the probe for physical damage. Use the software error correction feature if a consistent offset is observed.
- Alarm Triggering Frequently: Review your high and low temperature alarm settings. Ensure they are appropriate for your application. Check if the controlled environment is experiencing unusual temperature fluctuations.
- Output Not Activating: Verify that the heating/cooling mode and set points are correctly configured for the specific channel. Check the wiring to the connected device.
- Voltage Fluctuation Protection: The device is designed with protection against voltage fluctuations. If issues persist after a power surge, contact support.
8. Waarborg en Ondersteuning
Warranty information for the DAUZ WK-004 Digital Temperature Controller is not explicitly provided in the product details. For specific warranty terms, technical support, or spare parts availability, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.