Wedinard W218

Wedinard Water Quality Monitor W218 User Manual

Model: W218

Brand: Wedinard

Inleiding

The Wedinard W218 Water Quality Monitor is an advanced 8-in-1 wireless WiFi remote monitoring device designed for comprehensive water quality analysis. This instrument provides real-time data reception and automatic data storage, making it suitable for continuous monitoring in various environments.

Sleutel kenmerke sluit in:

  • 24-hour online monitoring capability.
  • Compatibility with iOS and Android systems for mobile app control.
  • Automatic language conversion based on mobile settings.
  • Wireless WiFi remote monitoring with multi-parameter testing.
  • Automatic correction and data storage for up to 30 days.

Produkkomponente

Wedinard Water Quality Monitor components

Figuur 1: verbyview of the Wedinard Water Quality Monitor and its included components. This image displays the main unit, various probes (pH, ORP, EC/TDS/SALT/CF), power adapter, and connection cables.

Die pakket sluit gewoonlik in:

  • Main Monitoring Unit (W218)
  • pH-sonde
  • ORP-ondersoek
  • EC/TDS/SALT/CF Probe
  • Temperature Probe (often integrated with pH/EC)
  • Power Adapter (EU Plug 230V)
  • USB kabel
  • Suction Cups for probe mounting

Opstel instruksies

  1. Uitpak: Carefully remove all components from the packaging. Inspect for any visible damage.
  2. Sondeverbinding:
    Close-up of pH and ORP probe connection ports

    Figuur 2: Close-up view of the pH and ORP probe input ports on the main unit, showing the BNC connectors.

    Connect the pH, ORP, and EC/TDS/SALT/CF probes to their respective ports on the main unit. Ensure connections are secure. The pH and ORP probes typically use BNC connectors.
  3. Kragverbinding: Plug the provided power adapter into the main unit and then into a standard 230V EU power outlet. The device will power on automatically.
  4. Sondeplasing: Submerge the probes into the water body you wish to monitor. Ensure the probes are fully immersed and stable. Use the provided suction cups if necessary to secure them.
  5. App Installasie: Download the official Wedinard water quality monitoring app from your mobile device's app store (compatible with iOS and Android).
  6. WiFi -verbinding: Open the app and follow the on-screen instructions to connect the device to your local WiFi network. This typically involves entering your WiFi credentials.

Bedryfsinstruksies

Wedinard Water Quality Monitor display showing readings

Figuur 3: The main unit display showing real-time readings for pH/Temperature, ORP, and EC/TDS/SALT/CF parameters.

  1. Intydse monitering: Once powered on and connected, the device will immediately begin displaying real-time readings on its integrated LCD screen for pH, ORP, EC, TDS, Salt, CF, and Temperature.
  2. App-koppelvlak:
    Wedinard Water Quality Monitor integrated into an aquarium setup

    Figuur 4: The Wedinard Water Quality Monitor in an aquarium setting, demonstrating its application for continuous monitoring.

    Access the mobile app to view detailed data, historical trends, and configure settings. The app allows for remote monitoring from anywhere with an internet connection.
  3. Databerging: The device automatically stores data for up to 30 days. This historical data can be accessed and analyzed through the mobile application. To view specific parameter details (e.g., pH), click on the corresponding section within the app to see daily, weekly, or monthly trends.
  4. Parameter Calibration:
    Wedinard Water Quality Monitor calibration screen

    Figuur 5: The calibration interface on the Wedinard Water Quality Monitor, indicating options for pH, ORP, and EC/TDS/SALT/CF calibration.

    The device supports automatic correction. For accurate readings, periodic calibration of probes is recommended. Refer to the app or device manual for specific calibration procedures using standard buffer solutions. pH calibration typically involves 3 points (e.g., 6.86, 4.00, 9.18 or 7.00, 4.00, 10.00).

Onderhoud

  • Sonde skoonmaak: Regularly clean the probes to prevent buildup that can affect accuracy. Use distilled water or a mild cleaning solution recommended for pH/ORP/EC probes. Avoid abrasive materials.
  • Probe Storage: When not in use for extended periods, store pH and ORP probes in their respective storage solutions or a 3M KCl solution to prevent drying out.
  • Kalibrasie: Calibrate the probes regularly, especially if readings appear inconsistent or after prolonged use. Frequency depends on usage and application.
  • Eenheid Skoonmaak: Vee die hoofeenheid af met 'n sagte, damp lap. Moenie die hoofeenheid in water dompel nie.
  • Sagteware-opdaterings: Check the mobile app periodically for firmware updates for the device to ensure optimal performance and access to new features.

Probleemoplossing

ProbleemMoontlike oorsaakOplossing
Toestel skakel nie aan nie.Kragadapter nie gekoppel of foutief nie; probleem met kragaansluiting.Ensure power adapter is securely connected. Test the power outlet with another device. Try a different power adapter if available.
Kan nie aan WiFi koppel nie.Incorrect WiFi password; device too far from router; router settings.Double-check WiFi password. Move the device closer to the router. Ensure your router supports 2.4GHz WiFi (most IoT devices do not support 5GHz). Restart router and device.
Onakkurate lesings.Probes are dirty or damaged; probes require calibration; expired calibration solution.Clean probes thoroughly. Perform a full calibration using fresh calibration solutions. Inspect probes for physical damage. Replace probes if necessary.
App vertoon nie data nie.No internet connection; app not synced with device; app bug.Verify your mobile device has an internet connection. Ensure the device is connected to WiFi. Restart the app. Reinstall the app if issues persist.
Data not saving for 30 days.Device storage issue; app synchronization problem.Ensure continuous power supply and WiFi connection. Check app settings for data retention. Contact support if the issue persists.

Spesifikasies

ParameterReeksResolusieAkkuraatheid
pH0.00-14.00pH0.01PH±0.03pH
ORP-2000mv ~ +2000mv1mv±5mv
EC0-19000us/cm, 0-199.0 ms/cm1us/cm (>1999us/cm), 0.1ms/cm±2%FS
CF0-1999.0CF1CF±2%FS
TDS0-19990ppm, 0-199.0ppt1 ppm (>1999ppm), 0.1 percentage punt±2%FS
Sout0-199.9ppt, 0%-20%1ppm (>1999ppm), 0.1 percentage point, 0.01%±2%FS
SG0.990-1.4000.001NVT
Temperatuur0-50°C (32°F~122°F)0.1°C (0.2°F)±1.0°C

Ander spesifikasies:

  • Battery: DC 6V
  • Temperatuurkompensasie: 0°C-50°C
  • Bedryfstemperatuur: 0°C-50°C
  • Produk afmetings: Approx. 152x80x26mm / 6.0x3.1x1.0in
  • Vervaardiger: Wedinard
  • Modelnommer: KFI-GT-5.2lk-267169

Aansoeke

Diagram showing various applications of water quality monitor

Figuur 6: Visual representation of the wide range of applications for the Wedinard Water Quality Monitor, including drinking water, swimming pools, fish tanks, water treatment, irrigation, and laboratories.

The Wedinard Water Quality Monitor is suitable for a wide range of applications, including but not limited to:

  • Aquariums and Glass Fish Ponds
  • Mynboubedrywighede
  • Mediese Navorsing
  • Agriculture (e.g., irrigation water)
  • Laboratoria
  • General Water Environment monitoring
  • Quality Control processes
  • Drinking Water analysis
  • Swembaddens
  • Water Treatment facilities

Waarborg en Ondersteuning

For warranty information and technical support, please refer to the official Wedinard webwebwerf of kontak hul kliëntediens direk. Bewaar u aankoopbewys as bewys van aankoop vir waarborgeise.

For further assistance, you may also refer to the product listing on Amazon.in for updated support contact details or FAQs.

© 2023 Wedinard. All rights reserved.

Hierdie handleiding is slegs vir inligtingsdoeleindes. Spesifikasies is onderhewig aan verandering sonder kennisgewing.