Reznor UDXC-60

Reznor UDXC-60 Natuurlike Gas Eenheid Verwarmer Instruksie Handleiding

Model: UDXC-60 | Brand: Reznor

1. Inleiding

The Reznor UDXC series natural gas heaters are designed to provide efficient and reliable heating for a variety of indoor spaces. These units are ideal for commercial, industrial, and residential applications such as garages, workshops, warehouses, and factories. The UDXC-60 model, with its 60,000 BTU output, offers quiet forced air heating, ensuring a comfortable environment while minimizing operational noise.

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Reznor UDXC-60 unit heater. Please read all instructions thoroughly before proceeding with installation or use.

Reznor UDXC-60 Natural Gas Unit Heater

Figuur 1: Voorkant view of the Reznor UDXC-60 Natural Gas Unit Heater.

2. Veiligheidsinligting

WAARSKUWING: Hierdie produk kan u blootstel aan chemikalieë, insluitend lood en loodverbindings, waarvan die staat Kalifornië bekend is dat dit kanker en geboortedefekte of ander reproduktiewe skade veroorsaak. Vir meer inligting gaan na www.P65Warnings.ca.gov.

  • Installation and service must be performed by a qualified installer, service agency, or gas supplier. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.
  • Verseker voldoende ventilasie in die installasiearea om die opbou van koolstofmonoksied te voorkom.
  • Moenie petrol of ander vlambare dampe en vloeistowwe in die omgewing van hierdie of enige ander toestel berg of gebruik nie.
  • Keep the area around the heater clear and free from combustible materials.
  • Always follow all local and national codes and regulations for gas appliance installation and operation.

3. Opstelling en installering

The Reznor UDXC-60 unit heater is designed for versatile mounting and venting options. Professional installation is highly recommended to ensure safety and compliance with all applicable codes.

3.1 Montering

The unit features threaded-nut retainers at four suspension points, allowing for secure installation as a ceiling-mounted hanging furnace or a wall-mounted heater. Mounting brackets are sold separately. Ensure the mounting structure can safely support the weight of the unit.

Reznor UDXC-60 Unit Heater with mounting points

Figure 2: Unit heater showing suspension points and external gas connection.

Mounting bracket for Reznor heater

Figuur 3: Example of a mounting bracket (sold separately).

3.2 Ontlugting

Proper venting is crucial for safe operation. The UDXC-60 is compatible with:

  • Category 1 double wall B-vent when venting vertically out of a roof.
  • Category 3 single wall vent pipe when vented horizontally through a sidewall.

Consult the detailed installation instructions provided with the unit for specific venting requirements and clearances.

3.3 Elektriese aansluiting

The unit requires a 24V electrical connection, accessible via an external terminal strip. All electrical wiring must comply with local and national electrical codes and be performed by a licensed electrician.

Simplified Installation and Advanced Features of Reznor Heater

Figuur 4: oorview of simplified installation features including electrical connections.

4. Bedryfsinstruksies

The Reznor UDXC-60 is designed for efficient and quiet operation, providing consistent heat for your space.

4.1 Verhittingsvlakke

The UDXC-60 offers two heating output levels to adapt to varying temperature needs:

  • Low Fire: 34,860 BTU, suitable for milder cool days.
  • Hoë Vuur: 49,800 BTU, for the coldest times of the year.

The unit achieves an 83% thermal efficiency rating, ensuring effective heat delivery.

Heating Flexibility of Reznor UDXC Heater

Figure 5: Illustration of the heater's heating flexibility with two BTU outputs.

4.2 Quiet Forced Air Heating

UDXC models are engineered for quiet operation, featuring a vibration/noise isolated low static pressure axial propeller fan and a power venting system. This design provides optimal performance in most indoor environments without excessive noise, making them ideal for spaces where sound levels are a concern.

Air Circulation in a garage with Reznor heater

Figure 6: Diagram illustrating efficient air circulation and heat distribution.

Features: Scratch Resistant, Durable Build, Modern Design, Quiet Operation

Figure 7: Key features highlighting quiet operation and durable design.

5. Onderhoud

Regular maintenance ensures the longevity and efficient operation of your Reznor UDXC-60 heater. Always disconnect power and gas supply before performing any maintenance.

  • Jaarlikse inspeksie: It is recommended to have a qualified service technician inspect the unit annually, especially before the heating season.
  • Skoonmaak: Keep the fan blades and heat exchanger clean from dust and debris. The improved cabinet design with a removable front face and a hinged access door panel with a quarter-turn latch facilitates easier access for cleaning and inspection.
  • Ventilasiestelsel-kontrole: Periodically inspect the vent system for any obstructions, leaks, or damage.
  • Gas Connection Check: Ensure all gas connections are secure and free from leaks.

6. Probleemoplossing

The Reznor UDXC-60 features an integrated circuit board with a 7-segment display and a status-indicating LED for simplified troubleshooting. Refer to the unit's display for error codes and status indicators.

  • No Heat/Unit Not Starting:
    • Gaan die termostaatinstelling na.
    • Verify the gas supply is on.
    • Ensure the power supply is connected and the built-in disconnect switch is engaged.
    • Check the 7-segment display for error codes.
  • Ongewone geluide:
    • Inspect the fan for obstructions or damage.
    • Ensure the unit is securely mounted and free from vibrations.
  • Poor Heating Performance:
    • Check for proper air circulation and clear any obstructions around the unit.
    • Ensure the correct heating level (low/high fire) is selected for the ambient temperature.

For persistent issues or complex problems, contact a qualified service technician.

7. Spesifikasies

KenmerkDetail
HandelsmerkReznor (Distributed by 1HVAC)
ModelnommerUDXC-60
Hitte-uitset60,000 BTU (Two levels: Low Fire 34,860 BTU / High Fire 49,800 BTU)
Termiese doeltreffendheid83%
Brandstof tipeAardgas
Binne/buiteluggebruikBinneshuise
Produk Afmetings (D x B x H)32.72" x 27" x 16.75"
Montage tipeCeiling Mount, Wall Mount (using suspension points)
Soort kamerGarage, Commercial, Industrial
Spesiale kenmerkFast Heating, Quiet Operation, Integrated Circuit Board with Display
HittewisselaarTCORE2 Titanium-Stabilized Aluminized Steel
Datum Eerste Beskikbaar14 Julie 2023
Dimensions of Reznor UDXC-60 Unit Heater

Figure 8: Key dimensions of the UDXC-60 unit heater.

Standard Features of Reznor Model UDXC-60 Unit Heater

Figuur 9: oorview of standard features including efficiency and heat exchanger material.

8. Waarborginligting

The Reznor UDXC-60 unit heater comes with the following warranty coverage:

  • 9 jaar: Heat Exchanger, Burner, and Flue Collection Box Assembly.
  • 4 jaar: All Electrical and Mechanical Components.

To ensure a valid warranty, installation must comply with all local and state codes. Retain your proof of purchase and installation records for warranty claims.

9. Ondersteuning en Kontak

For further assistance, technical support, or to purchase accessories and replacement parts, please refer to the contact information provided by your retailer or visit the official Reznor website. Always provide your model number (UDXC-60) when seeking support.

For more information about Reznor's commitment to quality and innovation, you can visit the 1HVAC Store on Amazon.

© 2023 Reznor. All rights reserved.

Verwante Dokumente - UDXC-60

Preview Reznor Gas Conversion Kit Installation for Gas-Fired Unit Heaters
This document provides installation instructions for Reznor gas conversion kits for various gas-fired unit heater models, including UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, and UDBS. It details component selection, safety precautions, and installation steps for converting between natural gas and propane, as well as for high-elevation installations.
Preview Reznor Ceiling Suspension Kit Installation Guide for Electric and Gas-Fired Unit Heaters
Installation instructions and component details for the Reznor CK22 Ceiling Suspension Kit, compatible with EHU electric and UDXC, UDX, UDZ gas-fired unit heaters. Learn how to safely mount your Reznor heater.
Preview Reznor-relaiset-installasiegids vir meervoudige eenheidbeheer (CL31/CL32)
Omvattende installasiegids vir Reznor CL31 en CL32 relaisets, wat beheer oor veelvuldige eenhede vir verskeie Reznor elektriese en gasverwarmers moontlik maak. Sluit komponentlyste, gedetailleerde installasiestappe en bedradingsspesifikasies in.
Preview Reznor Vertikale Louver-stel Installasiegids vir Gasaangedrewe Eenheidverwarmers (OPT-CD1)
Installasie-instruksies vir die Reznor OPT-CD1 Vertikale Louver-stel, ontwerp vir gasaangedrewe eenheidsverwarmers (modelle UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). Sluit komponentlys en stap-vir-stap monteringsgids in.
Preview VIVOSUN Fan-Forced Heater User Manual - Installation, Operation, and Safety Guide
Comprehensive user manual for the VIVOSUN Fan-Forced Heater, covering important instructions, safety information, specifications, installation, operation, maintenance, troubleshooting, and warranty details.
Preview Reznor UBXC/UDXC Gas-Fired Unit Heater Replacement Parts Manual
This manual provides detailed replacement parts information for Reznor UBXC and UDXC series gas-fired unit heaters. It includes sections on serial number decoding, electrical components, fan and motor assemblies, blower assemblies, cabinet components, heat exchanger and burner assemblies, venter and flue wrapper components, and various accessories and options.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.