The Zurn P6900-B-L AquaSense Electronics Module with Solenoid is a replacement component designed for Zurn AquaSense sensor faucets, specifically models Z6912, Z6913, Z6915, and Z6920. This module integrates the solenoid valve, battery pack, and the necessary wiring to connect to the faucet's infrared proximity sensor, enabling hands-free operation. This manual provides instructions for proper installation, operation, and maintenance of the module.
2. Veiligheidsinligting
- Always turn off the water supply to the faucet before beginning any installation or maintenance.
- Disconnect electrical power if applicable before servicing.
- Dra toepaslike persoonlike beskermende toerusting, soos veiligheidsbril en handskoene.
- Maak seker dat alle verbindings stewig is om lekkasies te voorkom.
- Gooi ou batterye verantwoordelik volgens plaaslike regulasies weg.
3. Pakketinhoud
Verifieer dat alle komponente teenwoordig is voordat u met die installasie begin:
- Zurn P6900-B-L AquaSense Electronics Module with Solenoid
- Batterypak (geïntegreerd)
- 4 AA alkaliese batterye (ingesluit)
- Connecting Wire to Faucet Sensor
- Small Hex Key/Wrench (for securing connections, if applicable)
- O-ring (for sealing connections, if applicable)

4. Opstelling en installering
Follow these steps to install the Zurn P6900-B-L Electronics Module:
- Skakel die watertoevoer af: Locate the main water shut-off valve for the faucet and turn it off completely.
- Disconnect Old Module (if replacing): Carefully disconnect the existing electronics module from the faucet sensor and water lines. Be prepared for residual water.
- Prepare New Module: Ensure the new P6900-B-L module has the included 4 AA alkaline batteries properly installed in the battery compartment.
- Verbind waterlyne: Attach the solenoid valve portion of the new module to the appropriate hot and cold water supply lines. Use thread sealant tape or pipe dope as recommended by local plumbing codes. Ensure connections are hand-tight, then use a wrench for a final quarter-turn, avoiding overtightening.
- Connect Sensor Wire: Carefully connect the wire from the electronics module to the faucet's infrared proximity sensor. The connector pins are delicate; align them precisely to avoid bending. Removing any rubber o-ring on the connector might assist in feeling for a solid connection, as a coupler nut typically secures the pieces.
- Veilige module: Mount or secure the electronics module in a suitable location, typically under the sink, ensuring it is protected from moisture and easily accessible for future maintenance.
- Herstel watervoorraad: Slowly turn the main water supply back on and check for any leaks at all connection points.
- Toetswerking: Activate the faucet sensor to verify proper water flow and shut-off.

5. Bedryfsinstruksies
The Zurn AquaSense Electronics Module controls water flow in conjunction with the faucet's infrared proximity sensor. To operate the faucet:
- Aktivering: Place your hands within the detection range of the faucet's sensor. The sensor will detect your presence.
- Watervloei: Upon detection, the electronics module will activate the solenoid valve, allowing water to flow from the faucet.
- Deaktivering: Remove your hands from the sensor's detection range. The module will then close the solenoid valve, stopping the water flow.
The system is designed for hands-free operation, promoting hygiene and water conservation.
6. Onderhoud
Regular maintenance ensures optimal performance and longevity of your Zurn AquaSense Electronics Module.
6.1. Battery vervanging
The module is powered by 4 AA alkaline batteries. When the batteries are low, the faucet may exhibit inconsistent operation or cease to function. To replace the batteries:
- Skakel die watertoevoer af: Skakel die watertoevoer na die kraan af.
- Toegang tot batterykompartement: Locate the battery compartment on the electronics module. This is typically secured with a cover.
- Verwyder ou batterye: Open the compartment and remove the old AA batteries.
- Plaas nuwe batterye in: Plaas vier nuwe AA alkaliese batterye in en maak seker dat die polariteit (+/-) korrek is.
- Veilige kompartement: Maak die batteryklepdeksel toe en maak dit vas.
- Herstel watertoevoer en toets: Turn the water supply back on and test the faucet's operation.
6.2. Skoonmaak
Periodically inspect the module and connections for any signs of corrosion or debris. Clean the exterior of the module with a soft, damp lap. Moenie skuur skoonmaakmiddels of oplosmiddels gebruik nie.
7. Probleemoplossing
If your Zurn AquaSense faucet is not functioning correctly, refer to the following table for common issues and solutions:
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| No water flow when sensor is activated | Lae of leë batterye Watertoevoer af Sensor wire disconnected or damaged Magneetklep wanfunksie | Vervang batterye Kontroleer watertoevoerklep Verify sensor wire connection Contact Zurn support for solenoid replacement |
| Water flows continuously | Sensor belemmer of foutief Solenoïdeklep vas oop | Clean sensor lens; check for obstructions Contact Zurn support for solenoid inspection/replacement |
| Swak watervloei | Lae waterdruk Belugter verstop Solenoid partially obstructed | Check building water pressure Clean or replace faucet aerator Contact Zurn support for solenoid inspection |
| Sensor reageer nie | Lae of leë batterye Sensor lens dirty Sensor wire disconnected or damaged | Vervang batterye Maak sensorlens skoon Verify sensor wire connection |
8. Spesifikasies
| Kenmerk | Detail |
|---|---|
| Model Naam | P6900-B-L |
| Deelnommer | P6900-B-L |
| Item gewig | 1.12 pond |
| Produk afmetings | 6 x 4 x 3.2 duim |
| Materiaal | Plastiek, metaal |
| Batterye | 4 AA Alkaliese batterye (ingesluit) |
| Compatible Faucets | Z6912, Z6913, Z6915, Z6920 Series |
| Spesiale kenmerk | Loodvry |
| UPC | 670240576582 |
9. Waarborg en Ondersteuning
The Zurn P6900-B-L AquaSense Electronics Module is covered by a limited manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your original Zurn product or visit the official Zurn webwebwerf.
For technical support, replacement parts, or further assistance, please contact Zurn Customer Service:
- Webwebwerf: www.zurn.com
- Kontakinligting: Refer to the 'Contact Us' section on the Zurn webwebwerf vir telefoonnommers en e-posondersteuning.