Zoeller 508-0006

Zoeller 508-0006 12 V Submersible Battery Back-Up Sump Pump System User Manual

Model: 508-0006

Inleiding en Veiligheidsinligting

This manual provides essential instructions for the safe installation, operation, and maintenance of your Zoeller 508-0006 12 V Submersible Battery Back-Up Sump Pump System. Please read this manual thoroughly before attempting to install or operate the pump. Failure to follow these instructions may result in property damage, serious injury, or death.

Algemene Veiligheidswaarskuwings

  • Always disconnect power before servicing the pump or battery.
  • Moenie die pomp met 'n beskadigde koord of prop gebruik nie.
  • Ensure all electrical connections are made by a qualified electrician and comply with local codes.
  • This pump is designed for clear water only. Do not use for sewage, flammable liquids, or chemicals.
  • Keep hands and feet clear of the pump inlet and discharge openings during operation.
  • Dra gepaste persoonlike beskermende toerusting (PPE) tydens installasie en onderhoud.
  • The battery used with this system contains sulfuric acid. Handle with care and follow battery manufacturer's safety guidelines.

Produk verbyview en kenmerke

The Zoeller 508-0006 is a reliable 12-volt DC submersible battery back-up sump pump system designed to activate automatically when your primary AC sump pump fails or during a power outage. It provides an essential layer of flood protection for your basement or crawl space.

Zoeller 508-0006 Battery Back-Up Sump Pump System

Figure 1: Zoeller 508-0006 Battery Back-Up Sump Pump System. This image shows the complete system including the pump, control box, and battery case.

Sleutel kenmerke:

  • Integrated Control Box: Features a 10 amp battery recharging system with overcharge protection.
  • LED-aanwysers: Clearly display battery power status and float switch activation.
  • Hoorbare alarms: Alert you to high water levels, reverse polarity, and low battery conditions.
  • Vertical Float Switch: Solid and buoyant polypropylene design for reliable activation.
  • Durable Battery Case: Constructed from non-corrodible polyethylene.
  • Ingesluit bykomstighede: DC pump discharge check valve, AC pump check valve, tee, and adapter for easy integration.
  • Kragkabel: 6-foot power cord for convenient connection.

Opstelling en installasie

Proper installation is crucial for the reliable operation of your battery back-up sump pump system. This system is designed to work as a backup to a primary sump pump.

1. Sump Pit Requirements

The sump pit must have a minimum diameter of 18 inches and a minimum depth of 22 inches to accommodate both the primary sump pump and the Zoeller 508-0006 system, including the battery case.

Sump Pit Diagram for Zoeller 508-0006 Installation

Figure 2: Illustrative diagram of a sump pit showing recommended dimensions for primary and backup pump placement.

2. Battery Installasie

  1. Place the battery case (non-corrodible polyethylene) in a suitable location near the sump pit, ensuring it is easily accessible for maintenance.
  2. Insert a 12V deep cycle marine battery (not included) into the battery case. The maximum battery dimensions are 13" L x 7-1/2" W x 9-1/2" H.
  3. Connect the battery cables from the control box to the battery terminals. Ensure correct polarity: red to positive (+), black to negative (-). The system has reverse polarity protection and an alarm.
Battery Connection Diagram for Zoeller 508-0006

Figure 3: Diagram showing proper battery connection to the control box, highlighting positive and negative terminals.

3. Pump and Plumbing Installation

  1. Position the Zoeller 508-0006 pump in the sump pit, ensuring it is below the primary pump's activation level but above the pit floor to prevent debris intake.
  2. Connect the pump's discharge to the included tee fitting. This tee allows both the primary pump and the backup pump to discharge through a common pipe.
  3. Install the included DC pump discharge check valve above the backup pump and the AC pump check valve above the primary pump to prevent backflow.
  4. Secure all plumbing connections to prevent leaks.
Zoeller 508-0006 Plumbing Diagram

Figure 4: Detailed plumbing diagram illustrating the connection of the backup pump, primary pump, check valves, and tee fitting to the discharge line.

4. Elektriese aansluiting

Plug the 6-foot power cord from the control box into a standard 120V AC outlet. The control box will begin charging the battery and monitoring the system.

Bedryfsinstruksies

The Zoeller 508-0006 system operates automatically once properly installed and powered.

Outomatiese werking

  • The system continuously monitors the battery charge and the water level in the sump pit.
  • If the water level rises above the primary pump's activation point and reaches the backup pump's float switch, the 12V DC pump will automatically activate and begin pumping water out of the pit.
  • The pump will continue to operate until the water level drops below the float switch's deactivation point.

Control Box Indicators and Alarms

The control box provides visual and audible feedback on the system's status:

  • LED Light (Battery Power): Indicates the current charge level of the battery. Refer to the control box label for specific light patterns and their meanings (e.g., green for charged, yellow for charging, red for low).
  • LED Light (Float Activated): Illuminates when the float switch is engaged and the pump is running.
  • Hoogwater alarm: An audible alarm will sound if the water level in the sump pit reaches a critical high point, indicating potential system failure or overwhelming water inflow.
  • Lae battery alarm: An audible alarm will sound if the battery charge drops to a critical level, indicating the need for inspection or replacement.
  • Reverse Polarity Alarm: An audible alarm will sound if the battery is connected incorrectly (positive to negative, negative to positive). Correct the connections immediately.

Onderhoud

Regular maintenance ensures the longevity and reliability of your Zoeller 508-0006 system.

Maandelikse tjeks:

  1. Toetswerking: Manually lift the float switch to activate the pump. Ensure the pump runs smoothly, discharges water, and the float activated LED illuminates.
  2. Battery inspeksie: Check the battery terminals for corrosion. Clean if necessary. Verify the battery fluid levels (if applicable for your battery type) and top off with distilled water if needed.
  3. Sump Pit Cleanliness: Inspect the sump pit for debris, dirt, or sediment that could obstruct the pump or float switch. Remove any obstructions.
  4. Terugslagkleppe: Ensure both the DC and AC pump check valves are functioning correctly and not leaking.

Jaarlikse kontroles:

  • Battery vervanging: Batteries typically last 3-5 years. Consider replacing your deep cycle marine battery every 3-5 years, or sooner if performance degrades.
  • Stelselinspeksie: Visually inspect all components for wear, damage, or loose connections.

Probleemoplossing

This section provides solutions to common issues you might encounter with your Zoeller 508-0006 system.

ProbleemMoontlike oorsaakOplossing
Pump does not run when float is activated.
  • Lae of dooie battery.
  • Los batteryverbindings.
  • Reverse polarity connection (alarm sounding).
  • Float switch obstructed or faulty.
  • Pomp motor mislukking.
  • Check battery charge via LED indicator. Recharge or replace battery.
  • Tighten battery terminal connections.
  • Correct battery cable connections (red to +, black to -).
  • Clear any obstructions around the float switch. Test float switch for proper movement.
  • Contact Zoeller support for pump inspection/replacement.
Low Battery Alarm sounds.
  • Die battery moet gelaai word.
  • Die battery is oud of foutief.
  • Control box not receiving AC power.
  • Allow time for the control box to recharge the battery.
  • Test battery with a multimeter; replace if necessary.
  • Check AC power outlet and control box power cord connection.
High Water Alarm sounds.
  • Backup pump not activating.
  • Backup pump unable to keep up with inflow.
  • Primary pump failure.
  • Refer to "Pump does not run" troubleshooting.
  • Check for blockages in discharge line. Ensure pump is not air-locked.
  • Inspect primary sump pump for operation.
Pomp loop voortdurend.
  • Float switch stuck in the "up" position.
  • Check valve failure (allowing water to flow back).
  • Clear any obstructions around the float switch.
  • Inspect and replace faulty check valves.

Spesifikasies

KenmerkDetail
Modelnommer508-0006
Voltage12V GS
Material (Pump/Float)Polipropileen (PP)
Material (Battery Case)Non-corrodible Polyethylene
Item gewig17 Pounds (pump only, without battery)
Lengte van die kragsnoer6 voet
Maximum Battery Dimensions (L x W x H)13" x 7-1/2" x 9-1/2"
Minimum Sump Pit Diameter18 duim
Minimum Sump Pit Depth22 duim
GPM @ 5 feet head39 GPM
GPM @ 10 feet head30 GPM
GPM @ 15 feet head20 GPM
GPM @ 20 feet head6 GPM
GPM @ 22 feet headAf

Waarborg en Ondersteuning

The Zoeller 508-0006 12 V Submersible Battery Back-Up Sump Pump System is covered under Zoeller's 3-year warranty. This warranty covers defects in materials and workmanship under normal use and service.

For warranty claims, technical assistance, or to purchase replacement parts, please contact Zoeller customer support. Keep your proof of purchase for warranty validation.

Zoeller Company Contact Information:
Please refer to the official Zoeller webwebwerf of produkverpakking vir die mees onlangse kontakbesonderhede.

© 2023 Zoeller Company. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.