APIELE XB2-01ZS

APIELE 22mm XB2-01ZS Emergency Stop Push Button Switch Instruction Manual

Model: XB2-01ZS | Handelsmerk: APIELE

1. Produk verbyview

The APIELE XB2-01ZS is a 22mm Normally Closed (NC) Red Mushroom Emergency Stop Push Button Switch designed for industrial and safety applications. This switch features a latching action, meaning it stays in the 'off' position once pressed and requires a turn to release it back to the 'on' position. It is rated for 600V and 10 Amps, providing a reliable safety mechanism for various equipment.

APIELE 22mm NC Red Mushroom Emergency Stop Push Button Switch

Beeld 1.1: Voorkant view of the APIELE 22mm NC Red Mushroom Emergency Stop Push Button Switch.

Sleutel kenmerke:

  • Tipe knoppie: Red Mushroom Head
  • Kontak Tipe: 1 Normally Closed (NC) silver contact
  • Aksie: Latching (Push-Lock, Turn to Release)
  • Montagegat grootte: 22 mm
  • Voltage-gradering: 600 V
  • Huidige gradering: 10 Amps
  • Materiaal: Plastic and Metal construction with silver contacts
Various APIELE Emergency Stop Push Button Switches

Image 1.2: A selection of APIELE emergency stop push button switches, showcasing different styles.

2. Spesifikasies

Detailed technical specifications for the XB2-01ZS Emergency Stop Push Button Switch are provided below:

Table of APIELE Emergency Stop Switch Specifications

Image 2.1: A table detailing the operating temperature, humidity, resistance, and mechanical/electrical life of the switch.

Tabel 2.1: Algemene spesifikasies
SpesifikasieWaarde
BedryfsmodusAutomatic, Push Button, Twist
Huidige gradering10 Amps
Bedryfsvoltage600 Volt
Kontak TipeNormaalweg gesluit (NC)
Connector TipeSkroef
TerminaleKnoppie
Stroombaan1-rigting
Montage tipePaneelmontering
Aktuator tipeDrukknop skakelaar
Kontak MateriaalSilwer
Internasionale BeskermingsgraadIP54
Aantal posisies2
Tipe beheerderDrukknop
Beheer metodeRaak
VerbindingsprotokolX-10
KleurRed (XB2-01ZS)
Eenheidtelling1 Tel
Item gewig3.2 onse
Pakket afmetings5.28 x 4.02 x 1.42 duim
VervaardigerAPI Electric
Technical drawing with dimensions of the 22mm Emergency Stop Switch

Image 2.2: Dimensional drawing of the 22mm emergency stop switch, showing key measurements in millimeters.

3. Installasie

This section provides instructions for installing the APIELE XB2-01ZS Emergency Stop Push Button Switch. Ensure all power is disconnected before beginning installation.

3.1 Komponentsamestelling

The switch consists of a contact base and an operation head (button). These components are designed for easy assembly and disassembly.

Diagram showing contact base, operation head, and assembled button

Beeld 3.1: Ontplof view showing the contact base, operation head, and the fully assembled button.

  1. demontage: To remove the switch head from the contact base, turn the handle of the switch head counter-clockwise. This will detach the head from the base.
  2. Vergadering: Align the switch head with the contact base and insert it. Turn the switch handle clockwise to lock the head securely onto the base.

The video below demonstrates the disassembly and assembly process for the emergency stop button switch.

Video 3.1: This video demonstrates how to disassemble and assemble the APIELE 22mm Emergency Stop Push Button Switch components.

3.2 Paneelmontering

The switch is designed for panel mounting with a 22mm diameter hole. Ensure the panel thickness is suitable (maximum 8.5mm / 0.3 inches).

  1. Drill a 22mm diameter hole in the desired mounting location on your control panel.
  2. Insert the switch head through the front of the panel.
  3. Secure the switch from the back of the panel using the provided locking nut and contact base.

3.3 Bedradingsinstruksies

The XB2-01ZS switch features a Normally Closed (NC) contact. This means the circuit is closed (current flows) when the button is in its released state, and opens (current stops) when the button is pressed.

Wiring diagrams for 2 NO or 2 NC and 1 NO 1 NC configurations

Image 3.2: Wiring diagrams illustrating connections for Normally Open (NO) and Normally Closed (NC) contacts. For this model (XB2-01ZS), refer to the NC contact diagram.

  • Identify the NC terminals on the contact block. These are typically labeled.
  • Connect the circuit wires to the screw terminals. Ensure connections are tight and secure to prevent electrical hazards.
  • Verify the wiring against your system's electrical diagram.

4. Operasie

The APIELE XB2-01ZS is an emergency stop switch designed for immediate cessation of machine operation in hazardous situations.

  1. To Activate (Stop): In an emergency, firmly press the red mushroom button. The button will latch into the depressed position, interrupting the circuit and stopping the connected device.
  2. To Deactivate (Release): To reset the switch and allow the device to operate again, turn the red mushroom button clockwise. The button will spring back to its original, released position, restoring the circuit.

The video below demonstrates the operational test of an emergency stop switch, showing how pressing the button stops a device and rotating it restarts the device.

Video 4.1: A real-world test demonstrating the push-to-stop and turn-to-release functionality of the emergency stop switch.

Examples of emergency stop switch applications in industrial settings

Beeld 4.1: Voorbeeldamples of typical applications for emergency stop switches, including control panels and machinery.

5. Onderhoud

Regular inspection and basic maintenance can help ensure the longevity and reliable operation of your emergency stop switch.

  • Visuele inspeksie: Periodically check the switch for any signs of physical damage, wear, or corrosion. Ensure the red mushroom head is intact and moves freely.
  • Funksionaliteitstoets: Regularly test the switch by pressing it to ensure it latches correctly and turning it to ensure it releases properly. Verify that the connected equipment responds as expected.
  • Skoonmaak: Keep the switch clean and free from dust, dirt, or debris. Use a soft, dry cloth for cleaning. Avoid using harsh chemicals or abrasive materials.
  • Verbindingskontrole: Ensure all wiring connections to the terminals remain tight and secure. Loose connections can lead to intermittent operation or electrical hazards.

6. Probleemoplossing

If you encounter issues with your APIELE Emergency Stop Push Button Switch, consider the following troubleshooting steps:

  • Switch Not Latching/Releasing:
    • Ensure the switch head is correctly assembled and locked onto the contact base.
    • Check for any obstructions preventing the button from fully depressing or rotating.
    • Inspect for internal damage if the mechanism feels stiff or unresponsive.
  • Device Not Stopping/Starting:
    • Verify all wiring connections are secure and correctly terminated to the NC contacts.
    • Check the continuity of the circuit with a multimeter when the switch is in both the pressed and released states.
    • Ensure the connected device's power supply is active and functioning.
    • Confirm that the switch's voltage and current ratings are appropriate for the application.
  • Intermitterende werking:
    • Inspect for loose wiring connections at the switch terminals or within the control panel.
    • Check for signs of corrosion on the contacts.

If these steps do not resolve the issue, contact APIELE customer support for further assistance.

7. Waarborg en Ondersteuning

APIELE provides a warranty for this product:

  • Waarborgtydperk: 3 jaar vanaf die datum van aankoop.
  • Dekking: Replacement for non-man-made defects.

For warranty claims, technical support, or any questions regarding the APIELE XB2-01ZS Emergency Stop Push Button Switch, please contact APIELE customer service.

Manufacturer: API Electric

Verwante Dokumente - XB2-01ZS

Preview Electrical Push Button Switch User Manual - 16mm, 19mm, 22mm
User manual for customized two-color metal push button switches. Includes safety information, technical specifications, and wiring diagrams for 16mm, 19mm, and 22mm models. Features LED illumination and latching/momentary options for automotive and marine applications.
Preview Industrial 22mm Push Button Control Box Enclosure
Tegnies verbyview and assembly guide for industrial empty control box enclosures compatible with 22mm push buttons, switches, and emergency stop indicators.
Preview LANBOO LB19/22M5.2 Metal Emergency Stop Switch Specifications
Detailed specifications for the LANBOO LB19/22M5.2 series of small-head, waterproof, metal emergency stop buttons. Features include IP65/IK10 rating, various contact configurations, and robust construction for industrial applications.
Preview XB5 Series 22mm Push Button and Key Switches Datasheet
Detailed specifications and dimensions for the XB5 series of 22mm illuminated push button switches, standard push buttons, emergency stop buttons, and key switches. Includes dimensional callouts for various models and types.
Preview FENGYIELE & XZ-JS01 Metal Push Button Switch User Manual | 16mm, 19mm, 22mm
Comprehensive user manual for FENGYIELE and XZ-JS01 series metal push button switches. Includes essential safety warnings, detailed technical specifications and dimensions for 16mm, 19mm, and 22mm models, and a basic wiring diagram. Features waterproof design and LED illumination. Compliant with EU directives.
Preview Allen-Bradley 22 mm Push Button Specifications Guide
Comprehensive technical specifications, product details, and ordering information for Allen-Bradley's 22 mm push button series (800F, 800FC, 800FD, 800MB, 800MR) and related components from Rockwell Automation.

Ask a question about this manual