1. Inleiding
This manual provides essential instructions for the safe and effective use of your PEGATRON PB018A2 Cable Modem Battery. This battery is designed to provide backup power for the telefoon diens functionality of compatible cable modems during power outages. It is an upgrade from the PB013 model and is compatible with Docsis 2.0, Docsis 3.0, and Docsis 3.1 Gateway Cable Modems, including specific models like DPC3939, DPC3941T, DPQ3925, and DPQ3212.
Important Note: This battery is intended to support the phone service part of your modem only. It does not provide backup power for internet connectivity during a power outage.
2. Veiligheidsinligting
- Moenie die batterypak uitmekaar haal, oopmaak of versnipper nie.
- Moenie die battery aan hitte of vuur blootstel nie. Vermy berging in direkte sonlig.
- Do not short-circuit the battery pack. Do not store battery packs haphazardly in a box or drawer where they may short-circuit each other or be short-circuited by other metal objects.
- Moenie die batterypak uit die oorspronklike verpakking verwyder voordat dit vir gebruik benodig word nie.
- Moenie batterypakke aan meganiese skok onderwerp nie.
- Indien 'n battery lek, moenie toelaat dat die vloeistof in kontak kom met die vel of oë nie. Indien kontak gemaak is, was die aangetaste area met oorvloedige hoeveelhede water en raadpleeg 'n dokter.
- Moenie enige ander laaier gebruik as wat spesifiek voorsien is vir gebruik met die toerusting nie.
- Let op die plus (+) en minus (-) merke op die battery en toerusting en verseker korrekte gebruik.
- Hou die batterypak buite bereik van kinders.
- Soek onmiddellik mediese advies indien 'n sel of battery ingesluk is.
- Consult your modem's manual for specific battery compartment instructions.
3. Pakketinhoud
Verifieer dat jou pakket die volgende items bevat:
- 1 x PEGATRON PB018A2 Cable Modem Battery
- Hierdie gebruikershandleiding
4. Opstelling en installering
Follow these steps to install the battery into your compatible cable modem:
- Identify the Battery Compartment: Locate the battery compartment on your cable modem. This is typically on the back or bottom of the device. Refer to your modem's specific user manual if you have difficulty locating it.
- Maak die kompartement oop: Carefully open the battery compartment cover. This may involve sliding a latch or removing screws.
- Plaas die battery in: Align the PEGATRON PB018A2 battery with the compartment, ensuring the connectors match the modem's terminals. Gently push the battery into place until it is securely seated.

Figuur 1: Kant view of the battery, highlighting the connector pins for proper insertion.
- Maak die kompartement toe: Plaas die deksel van die batterykompartement terug en maak dit vas.
- Aanvanklike laai: After installation, the battery will begin to charge. It may take up to 5 dae for the battery to fully charge and assume its full backup power capacity. During this period, the modem's battery indicator light may show a charging status.

Figuur 2: Bo view of the PEGATRON PB018A2 battery, showing model number and specifications.
5. Bedryfsinstruksies
Once installed and fully charged, the PEGATRON PB018A2 battery operates automatically:
- Normale werking: When your modem is connected to AC power, the battery remains in standby mode, continuously charging to maintain full capacity.
- Krag Outage: In die geval van 'n krag outage, the battery will automatically provide power to your cable modem's phone service functionality. This allows you to continue making and receiving calls through your landline phone service for approximately 8 hours, depending on usage and modem model.
- Kragherstel: When AC power is restored, the modem will switch back to wall power, and the battery will automatically begin recharging.
6. Onderhoud
- Batterylewe: The typical lifespan of a Lithium-Ion battery is several years. However, performance may degrade over time.
- Vervanging: If you notice a significant reduction in backup time or if the battery indicator on your modem suggests a fault, it may be time to replace the battery.
- Berging: If storing the battery for an extended period, ensure it is partially charged (around 50%) and stored in a cool, dry place within the recommended temperature range (-20°C to 60°C).
- Beskikking: Dispose of old batteries responsibly according to local regulations for Lithium-Ion batteries. Do not dispose of in household waste.
7. Probleemoplossing
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| Battery not charging or modem not recognizing battery. |
|
|
| No phone service during a power outage. |
|
|
| Battery causes interference or cuts Wi-Fi signal. |
|
|
8. Spesifikasies
| Kenmerk | Detail |
|---|---|
| Modelnommer | PB018A2 (Upgrade from PB013) |
| Battery Tipe | Litium-ioon |
| Kapasiteit | 3000mAh |
| Bedryfstemperatuur | -20°C tot 65°C (-4°F tot 149°F) |
| Bergingstemperatuur | -20°C tot 60°C (-4°F tot 140°F) |
| Versoenbare modems | DPC3939, DPC3941T, DPQ3925, DPQ3212 (Docsis 2.0, 3.0, 3.1 Gateway Cable Modems) |
| Estimated Backup Time | Up to 8 hours (for phone service only) |
| Vervaardiger | PEGATRON |
9. Waarborg en Ondersteuning
Vir waarborginligting en tegniese ondersteuning, verwys asseblief na die dokumentasie wat saam met u aankoop verskaf is of kontak die verkoper direk. Bewaar u bewys van aankoop vir enige waarborgeise.
For specific questions regarding your cable modem's functionality or compatibility, please contact your internet service provider (e.g., Comcast Xfinity).