1. Inleiding
Thank you for choosing the CREATE SILKAIR CONNECT 3-in-1 Mobile Air Conditioner. This versatile appliance is designed to provide cooling, dehumidification, and fan functions for your living space. With its Wi-Fi connectivity, you can conveniently control the unit via a mobile application. Please read this manual thoroughly before operation to ensure safe and efficient use.
Model: 64274_145198
Handelsmerk: SKEP
2. Veiligheidsinligting
Volg altyd basiese veiligheidsmaatreëls wanneer u elektriese toestelle gebruik om die risiko van brand, elektriese skok en beserings te verminder.
- Maak seker dat die kragtoevoer ooreenstem met die voltage gespesifiseer op die graderingetiket.
- Moenie die eenheid met 'n beskadigde koord of prop gebruik nie.
- Hou die eenheid weg van hittebronne en direkte sonlig.
- Moenie luginlate of -uitlate blokkeer nie.
- Ontkoppel altyd die eenheid se stekker voor skoonmaak of onderhoud.
- Hierdie toestel gebruik R290-koelmiddel. Moenie die koelmiddelkring deurboor nie.
- Hou toesig oor kinders en maak seker dat hulle nie met die toestel speel nie.
3. Pakketinhoud
Carefully unpack your air conditioner and check that all items are present and in good condition.
- CREATE SILKAIR CONNECT Mobile Air Conditioner Unit
- Uitlaatslang
- Window Sealing Kit (Adjustable window slider, hose adapter)
- Afstandbeheer
- Gebruikershandleiding

Figure 1: The CREATE SILKAIR CONNECT Mobile Air Conditioner unit shown alongside a smartphone displaying its control application interface.
4. Produk verbyview
4.1 Beheerpaneel

Figure 2: Close-up of the top-mounted control panel, featuring an LED display and touch-sensitive buttons for various functions such as power, mode selection, fan speed, and timer.
4.2 Komponente en Afmetings

Figure 3: Detailed diagram illustrating the dimensions of the window sealing plate (125.5 cm length, 10 cm width, 9.5 cm adjustable width) and the exhaust hose (125 cm length) with its adapter (23.8 cm diameter).
5. Opstelling en installering
Proper installation is crucial for the efficient operation of your mobile air conditioner.
5.1 Posisionering van die eenheid
- Plaas die eenheid op 'n plat, stabiele oppervlak.
- Ensure there is at least 30 cm of space around the unit for proper airflow.
- Plaas die eenheid naby 'n venster of opening vir die uitlaatpyp.

Figure 4: The air conditioner unit positioned in a room, demonstrating the typical setup with the exhaust hose directed towards a window for heat expulsion.
5.2 Installing the Exhaust Hose and Window Kit
- Attach the hose adapter to one end of the exhaust hose.
- Koppel die ander kant van die uitlaatpyp aan die luguitlaat aan die agterkant van die eenheid.
- Install the adjustable window sealing kit in your window opening. Extend it to fit the window frame.
- Insert the hose adapter into the opening of the window sealing kit.

Figure 5: Illustrates the secure connection of the flexible exhaust hose to the designated port at the rear of the air conditioning unit.

Figure 6: The window sealing kit is shown properly installed in a window frame, with the exhaust hose securely fitted into the kit's opening to vent hot air outside.
6. Bedryfsinstruksies
6.1 Gebruik die beheerpaneel
The control panel on top of the unit allows direct operation.
- Kragknoppie: Druk om die eenheid AAN of AF te skakel.
- Modusknoppie: Cycle through Cooling, Fan, and Dehumidifier modes.
- Fan Speed Button: Adjust fan speed (Low, High).
- Temperatuurknoppies (+/-): Adjust desired temperature in Cooling mode.
- Timer-knoppie: Set the auto-on or auto-off timer (up to 24 hours).
- Slaapmodus-knoppie: Activates a quieter operation mode for nighttime use.

Figure 7: A user's hand interacting with the touch-sensitive control panel located on the top surface of the air conditioner, demonstrating direct manual operation.
6.2 Gebruik van die afstandbeheer
The remote control provides convenient operation from a distance.

Figure 8: A hand holding the dedicated remote control for the air conditioner, illustrating its use for convenient operation from a distance.
6.3 Wi-Fi en toepassingbeheer
Download the CREATE Home app from your smartphone's app store. Follow the in-app instructions to connect your air conditioner to your home Wi-Fi network. Once connected, you can control all functions of the unit from your smartphone, including mode selection, temperature adjustment, fan speed, and timer settings.

Figure 9: A user interacting with the mobile application on a smartphone to remotely control the air conditioner, showcasing the Wi-Fi connectivity feature.
7. Onderhoud
Gereelde onderhoud verseker optimale prestasie en verleng die lewensduur van u eenheid.
7.1 Skoonmaak van die lugfilter
Die lugfilter moet elke twee weke of meer gereeld skoongemaak word, afhangende van gebruik en luggehalte.
- Skakel die eenheid af en trek die stekker uit die stopcontact.
- Locate the air filter panel on the back of the unit.
- Verwyder die filter liggies.
- Clean the filter with warm, soapy water or a vacuum cleaner. Rinse thoroughly and allow it to air dry completely before reinserting.

Figure 10: Demonstrates the process of removing the air filter from the rear of the air conditioner unit for cleaning or replacement.
7.2 Dreineer Water
In Dehumidifier mode or high humidity conditions, the internal water tank may fill up. The unit will stop operating when the tank is full. Drain the water from the drainage port at the bottom rear of the unit.
8. Probleemoplossing
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| Eenheid skakel nie aan nie | No power; Power cord not plugged in; Water tank full. | Check power outlet; Plug in power cord; Drain water tank. |
| Eenheid verkoel nie effektief nie | Air filter dirty; Exhaust hose not properly installed; Room too large; Doors/windows open. | Clean air filter; Ensure hose is sealed; Use in recommended room size (14-25 m²); Close doors/windows. |
| Harde geraas | Eenheid nie op 'n plat oppervlak nie; Obstruksie in waaier. | Place on flat surface; Check for obstructions. |
| Wi-Fi-verbindingskwessies | Verkeerde Wi-Fi-wagwoord; Router te ver; App-probleme. | Verify password; Move unit closer to router; Restart app/unit. |
9. Spesifikasies
| Kenmerk | Spesifikasie |
|---|---|
| Modelnommer | 64274_145198 |
| Verkoelingskapasiteit | 9000 BTU / 2270 Watt |
| Ontvochtigingskapasiteit | 24 liter/dag |
| Lugvloei | Tot 350 m³/h |
| Aanbevole kamergrootte | 14-25 m² |
| Geraasvlak | 65 dB |
| Koelmiddel | R290 (ECO-friendly) |
| Voltage | 240 Volt |
| Wattage | 2600 watt |
| Afmetings (L x B x H) | 35.5 x 36.5 x 71.3 cm |
| Materiaal | ABS |
| Energiedoeltreffendheidklas | A |

Figure 11: The energy efficiency label for the CREATE SILKAIR CONNECT, indicating an A-class energy rating, 2.6 kW cooling capacity, and a noise level of 65 dB. More details can be found at eprel.ec.europa.eu/qr/1580267.
10. Waarborg en Ondersteuning
For warranty information and technical support, please refer to the warranty card included with your product or visit the official CREATE webwebwerf. Bewaar u aankoopbewys as bewys van aankoop.
Vervaardiger: SKEP
Kontak: Refer to CREATE's official support channels.