Suuwer S725

Suuwer S725 Heat Pump Thermostat User Manual

Model: S725

Inleiding

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Suuwer S725 5-1-1 Day Programmable Heat Pump Thermostat. Please read this manual thoroughly before installation and use to ensure proper functionality and to avoid potential issues.

Suuwer S725 thermostat mounted on a wall in a modern living space.

Figure 1: Suuwer S725 Heat Pump Thermostat installed on a wall.

Pakketinhoud:

  • Suuwer S725 Heat Pump Thermostat
  • Two mounting screws and anchors
  • Installation Manual (integrated into this document)
  • Kabel etikette

Produk Kenmerke

The Suuwer S725 thermostat offers a range of features designed for efficient home climate control:

  • Stelselversoenbaarheid: Designed for Heat Pump systems (with or without auxiliary/emergency heat) and most 24V conventional single-stage systems (gas, oil, electric furnaces) up to 2 Heat and 1 Cool.
  • Programmeerbaarheid: 5-1-1 Day Programmable with separate programs for weekdays and weekends, featuring 4 program periods per day (Wake, Leave, Return, Sleep).
  • Vertoon: 4.5 sq. inch large LCD display with a white backlight, simultaneously showing room temperature, set temperature, and current time.
  • Fan beheer: Fan switch with ON and AUTO functions.
  • Kragopsies: Dual powered by 24VAC or 2 AAA batteries. No common wire (C-wire) required on most systems (required for heat-only and cool-only systems).
  • Temperatuurbeheer: Separate heating and cooling swing (cycle rate) adjustable from 0.2°F to 2°F.
  • Kompressorbeskerming: 5-minute compressor delay protection (selectable ON or OFF).
  • Aanwysers: Low battery indicator and air filter change indicator (selectable ON or OFF, settable from 50-2000 hours).
  • Kalibrasie: Room temperature calibration adjustment.
  • Vertoonopsies: Fahrenheit or Celsius temperature display, 12 or 24-hour clock.
  • Terminale benamings: RH, G, Y, C, O, B, E, W2.

Verenigbaarheid

The Suuwer S725 thermostat is compatible with the following HVAC systems:

  • Heat Pump systems (with auxiliary or emergency heat)
  • Heat Pump systems (without auxiliary heat)
  • Most 24V conventional single-stage systems (e.g., conventional forced air, central gas, oil, or electric furnaces) up to 2 Heat and 1 Cool.

Onversoenbare Stelsels:

  • 110-240V electric heat systems (e.g., electric baseboard heat, line voltage, convectors, radiant-ceiling heat).
  • Conventional multi-stage stelsels.
  • Mini-split systems.
  • 12V RV thermostats.

Before installation, verify your existing system's compatibility. If your current thermostat has stranded wires or is labeled 110V or 120V, it is not compatible with this thermostat.

Diagram showing how to identify incompatible systems by checking for stranded wires or 110V/120V labels on the old thermostat.

Figure 2: Identifying incompatible systems by checking old thermostat wiring and voltage labels.

Opstelling en installasie

Veiligheidsmaatreëls:

  • Turn off power to the heating/cooling system at the main fuse or circuit breaker panel before beginning installation.
  • Ensure all wiring is performed by a qualified individual if you are unsure.

Removing Your Old Thermostat:

  1. Skakel die krag na jou verhittings- en verkoelingstelsel by die stroombreker af.
  2. Verwyder die deksel van jou ou termostaat.
  3. Take a picture of the wiring connections for reference.
  4. Label each wire with the provided cable labels according to its terminal designation.
  5. Disconnect the wires and remove the old thermostat's mounting base.

Mounting the New Thermostat:

  1. Position the new thermostat's sub-base on the wall where the old thermostat was located.
  2. Merk die monteringsgate.
  3. Boor vlieëniergate indien nodig en plaas die muurankers.
  4. Feed the wires through the opening in the sub-base.
  5. Secure the sub-base to the wall using the provided screws.

Bedrading verbindings:

Connect the labeled wires to the corresponding terminals on the Suuwer S725 thermostat's sub-base. Refer to the wiring diagrams below for common system types.

Terminal Designations and Functions
TerminaleFunction (Heat Pump System)Function (Conventional System)
RTransformator KragTransformator Krag
CTransformer Common (Optional 24 VAC common connection when thermostat is used in battery power mode)Transformator Common
BOmskakelklep wat in HITTE geaktiveer wordNVT
OOmskakelklep bekragtig in KOELNVT
GFan RelayFan Relay
W/EEerste Stage van Nood HEATEerste Stage van HEAT
W2Tweede Stage van HEAT/NOOD HEATTweede Stage van HEAT
YEerste Stage van HITTE en VERKOELEerste Stage van COOL

Let wel: Use either O or B terminals for the changeover valve, but not both. In many systems with no emergency heat relay, a jumper can be used between E and W2.

Wiring terminal block on the back of the thermostat and a table showing terminal designations for Heat Pump and Conventional systems.

Figure 3: Thermostat wiring terminals and a compatibility chart for wire connections.

Detailed wiring diagrams for a typical 2H/1C Heat Pump System and a Conventional System 1H/1C, 2H/1C.

Figure 4: Wiring diagrams for 2H/1C Heat Pump systems (with and without emergency heat) and Conventional systems.

Battery installasie:

The thermostat can be powered by 24VAC or two AAA batteries. If using batteries, open the easy-access battery compartment and insert two fresh AAA alkaline batteries, observing polarity.

Thermostat with the battery compartment open, showing two AAA batteries being inserted.

Figure 5: Battery compartment with AAA batteries.

Voltooiing van installasie:

Once wiring is complete and batteries are installed (if applicable), carefully align the thermostat body with the sub-base and snap it into place. Restore power to your HVAC system at the circuit breaker.

Bedryfsinstruksies

The Suuwer S725 thermostat features a clear LCD display and intuitive buttons for easy operation.

Voorkant view of the Suuwer S725 thermostat with its blue backlit LCD display showing room temperature, set temperature, and current time.

Figuur 6: Voorkant view of the thermostat display and controls.

Kontroles verbyview:

  • Menu Buttons (Left Side): Used for accessing settings like Tech Set, Set Time, Set Sched (Schedule).
  • Up/Down Arrows (Right Side): Used to adjust temperature settings and navigate menu options.
  • FAN Switch:
    • OP: Waaier loop aanhoudend.
    • VOERTUIG: Fan runs only when heating or cooling system is active.
  • STELSEL Skakelaar:
    • AF: Stelsel is uit.
    • HITTE: Termostaat beheer verhitting.
    • KOEL: Termostaat beheer verkoeling.
    • EMH (Emergency Heat): Activates emergency heat (for heat pump systems with auxiliary heat).

Setting the Current Time and Day:

  1. Press the "Set Time" button.
  2. Use the Up/Down arrows to adjust the hour, then press "Set Time" again to move to minutes.
  3. Adjust minutes, then press "Set Time" to move to the day of the week.
  4. Adjust the day, then press "Set Time" or wait for the thermostat to return to the main display.

Programming the Schedule (5-1-1 Day):

The thermostat allows for separate programming for weekdays (Monday-Friday), Saturday, and Sunday, with four periods per day: Wake, Leave, Return, and Sleep.

  1. Press the "Set Sched" button.
  2. The display will show the current program period (e.g., "Wake") and the day(s) being programmed.
  3. Use the Up/Down arrows to adjust the start time for the current period, then press "Set Sched".
  4. Use the Up/Down arrows to adjust the desired temperature for the current period, then press "Set Sched".
  5. Repeat steps 3 and 4 for all four periods (Wake, Leave, Return, Sleep) for the weekdays.
  6. After programming weekdays, the thermostat will move to Saturday, then Sunday. Repeat the process for these days.
  7. Once all periods are set, press "Set Sched" or wait for the thermostat to return to the main display.

Verstel temperatuur:

In normal operating mode, use the Up/Down arrows to temporarily adjust the set temperature. The thermostat will hold this temperature until the next scheduled program period begins.

System Mode Selection:

Use the SYSTEM switch to select your desired operating mode: OFF, HEAT, COOL, or EMH (Emergency Heat).

Fan Mode Selection:

Use the FAN switch to select between ON (continuous fan operation) or AUTO (fan operates only when heating/cooling).

Onderhoud

Battery vervanging:

When the low battery indicator appears on the display, replace the two AAA batteries promptly to ensure continuous operation. Open the easy-access battery compartment on the front of the thermostat to replace them.

Air Filter Change Reminder:

The thermostat features an air filter change indicator. This reminder can be set in the technical settings (Tech Set) for intervals between 50 and 2000 hours. When the indicator appears, it is recommended to check and replace your HVAC system's air filter.

Skoonmaak:

Maak die buitekant van die termostaat skoon met 'n sagte, damp lap. Moenie skuur skoonmaakmiddels of oplosmiddels gebruik nie.

Probleemoplossing

As jy probleme met jou termostaat ondervind, raadpleeg die volgende algemene probleme en oplossings:

ProbleemMoontlike oorsaakOplossing
Geen vertoon of leë skerm nie.No power or dead batteries.Check circuit breaker. Replace AAA batteries if running on battery power. Ensure 24VAC power is connected if not using batteries.
Verhittings-/verkoelingstelsel reageer nie.Incorrect wiring, system switch in OFF position, or compressor delay.Verify wiring connections. Ensure SYSTEM switch is set to HEAT or COOL. Wait 5 minutes for compressor delay protection to cycle.
Temperatuur onakkuraat.Thermostat location, calibration needed.Ensure thermostat is not in direct sunlight or near heat sources. Perform room temperature calibration adjustment (refer to advanced settings).
Thermostat runs AC when set to HEAT (or vice-versa).Incorrect wiring of O/B terminals or system configuration.Verify O/B wire connections. Check technical settings for correct system type (Heat Pump vs. Conventional) and O/B valve operation.
Fan not operating correctly.Fan switch setting.Ensure FAN switch is set to ON for continuous operation or AUTO for operation with heating/cooling cycles.

Indien probleme voortduur nadat u hierdie oplossings probeer het, kontak kliëntediens vir verdere hulp.

Spesifikasies

KenmerkDetail
Model NaamS725 Heat Pump Thermostat
Produk afmetings0.98" D x 4.72" B x 3.86" H
Tipe beheerderDrukknop
Spesiale kenmerke5-1-1 Day Programmable, Separate Heating and Cooling Swing, Low Battery Indicator, 5 Minute Compressor Delay Protection, Air Filter Change Indicator, Room Temperature Calibration Adjustment
KleurOff-white (Blue Backlight)
Spesifieke gebruikeCompatible with Heat Pump systems (with aux or emergency heat) and Heat Pump (without aux) systems.
Tipe temperatuurbeheer2 Heating and 1 Cooling
KragbronBattery Powered (2x AAA) or 24VAC
Voltage24 Volt (AC)
MateriaalPlastiek
Tipe vertoonDigitale LCD met agtergrondbeligting
Skerm grootte4.5 duim (diagonaal)
Montage tipeMuurmontering
Item gewig8.1 onse
Temperatuur vertoon reeks41°F tot 95°F
Temperatuurbeheerreeks44°F tot 90°F
Laai gradering1 Amp per terminaal, 1.5 Amp maksimum alle terminale gekombineer
Diagram showing the dimensions of the Suuwer S725 thermostat: 4.72 inches wide, 3.86 inches high, and 0.98 inches deep.

Figure 7: Product dimensions of the Suuwer S725 thermostat.

Waarborg & Ondersteuning

The Suuwer S725 Heat Pump Thermostat comes with a 2 jaar sorgvrye waarborg.

For technical assistance or warranty claims, please contact Suuwer customer service. Support is available 24 hours a day.

Before contacting support, please have your product model number (S725) and a description of the issue ready.