Inleiding
The Perel EDIN305N is a 230V 16A 3600W DIN-rail mount digital weekly timer designed for indoor use. This device allows for precise, programmable control of electrical circuits, enabling automatic switching ON and OFF of connected appliances or lighting systems over a weekly cycle. It features a clear digital display and multiple programming options to suit various scheduling needs.
Veiligheidsmaatreëls
WAARSKUWING: Electrical installation should only be performed by a qualified electrician. Incorrect wiring can lead to electric shock, fire, or damage to the device and connected equipment. Always disconnect power at the main circuit breaker before installation or maintenance.
- Ensure the power supply matches the device's specifications (230V~50Hz).
- Moenie die maksimum laaikapasiteit van 16A / 3600W oorskry nie.
- This device is designed for indoor use only. Avoid exposure to moisture, dust, or extreme temperatures.
- Moenie probeer om die toestel self oop te maak of te herstel nie. Verwys alle diens na gekwalifiseerde personeel.
- Hou buite bereik van kinders.
Produk verbyview
The Perel EDIN305N digital timer consists of a main body with a digital display, control buttons, and terminal blocks for electrical connections. A transparent cover protects the display and buttons.

Figuur 1: Voorkant view of the Perel EDIN305N Digital Weekly Timer. The image displays the LCD screen, control buttons (R, W+, H+, M+, C+, Clock, Manual, RES/RCL), and numbered terminal blocks (1, 2 at the top, 3, 4, 5 at the bottom).
Beheerknoppies:
- R: Reset button (recessed).
- W+: Weekday setting.
- H+: Uur instelling.
- M+: Minute setting.
- C+: Clear program.
- Horlosie-ikoon: Used to set current time and day, and to exit programming mode.
- HANDLEIDING: Manual override for ON/AUTO/OFF modes.
- RES/RCL: Reset/Recall program.
Eindblokke:
- 1, 2: Power supply input (N, L).
- 3, 4, 5: Output terminals for controlled circuit (Common, Normally Open, Normally Closed).
Tegniese spesifikasies
| Parameter | Waarde |
|---|---|
| Modelnommer | EDIN305N |
| Voltage | 230V~50Hz |
| Maks. Huidige | 16A |
| Maks. Krag | 3600 W |
| Aantal instellings | 7 (AAN/AF programme) |
| Montage tipe | DIN-spoor |
| Afmetings (L x B x H) | 2.36 x 3.54 x 1.57 duim (60 x 90 x 40 mm) |
| Gewig | 0.12 kg (4.2 onse) |
| Materiaal | Plastiek |
| Kleur | Wit |
| Batterye benodig | No (internal battery for memory backup) |
Installasie
1. Montering
The Perel EDIN305N is designed for DIN-rail mounting. Securely attach the timer to a standard 35mm DIN-rail within an electrical enclosure. Ensure sufficient space for wiring and ventilation.
2. Bedrading
BELANGRIK: Ensure power is disconnected at the main circuit breaker before proceeding with wiring. Follow local electrical codes and regulations.

Figuur 2: Kant view of the Perel EDIN305N Digital Weekly Timer showing the electrical wiring diagram. It illustrates connections for Neutral (N), Live (L), and the output contacts (1, 2, 3, 4, 5) for controlling a load.
Refer to the wiring diagram (Figure 2) and the terminal block labels on the device:
- Connect the Neutral (N) wire of your 230V AC supply to terminal 1.
- Connect the Live (L) wire of your 230V AC supply to terminal 2.
- For the controlled circuit:
- Terminal 3: Common contact for the relay output.
- Terminal 4: Normally Open (NO) contact. The circuit connected here will be ON when the timer is active.
- Terminal 5: Normally Closed (NC) contact. The circuit connected here will be OFF when the timer is active.
- Connect the load (e.g., light, appliance) between the Live (L) supply and either terminal 4 (for NO operation) or terminal 5 (for NC operation), with terminal 3 connected to the Live (L) supply. Alternatively, connect the load between terminal 4 or 5 and the Neutral (N) supply, with terminal 3 connected to the Live (L) supply. Consult a qualified electrician for specific load wiring configurations.
Aanvanklike opstelling en werking
1. Power On and Reset
After wiring and restoring power, the display will illuminate. If the display is blank or shows erratic characters, press the recessed R (Reset) button using a pointed non-metallic object (e.g., a pen tip). This will clear all settings and restore default values.
2. Instelling van Huidige Tyd en Dag
- Druk en hou die Horlosie-ikoon knoppie.
- Terwyl jy die Horlosie-ikoon knoppie, druk W+ to set the current day of the week (1=Monday, 7=Sunday).
- Terwyl jy die Horlosie-ikoon knoppie, druk H+ om die huidige uur in te stel (0-23).
- Terwyl jy die Horlosie-ikoon knoppie, druk M+ om die huidige minuut (0-59) in te stel.
- Los die Horlosie-ikoon button. The time and day are now set.
3. Programming ON/OFF Cycles
The timer supports up to 7 ON/OFF programs. Each program consists of an ON time and an OFF time.
- Druk die Horlosie-ikoon knoppie een keer om programmeringsmodus te betree. Die skerm sal "1 AAN" wys.
- Druk W+ to select the day(s) for this program. You can choose a single day, a block of days (e.g., Mon-Fri), or all days.
- Druk H+ to set the ON hour for program 1.
- Druk M+ to set the ON minute for program 1.
- Druk die Horlosie-ikoon button again. The display will show "1 OFF".
- Repeat steps 2-4 to set the OFF day(s), hour, and minute for program 1.
- To set additional programs (2-7), press the Horlosie-ikoon button to cycle through "2 ON", "2 OFF", etc., and repeat the setting process.
- Nadat al die verlangde programme ingestel is, druk die HANDLEIDING knoppie om die programmeringsmodus te verlaat en terug te keer na die huidige tydvertoning.
4. Handmatige oorskrywing
Druk die HANDLEIDING knoppie herhaaldelik om deur die bedryfsmodusse te blaai:
- OP: The output is continuously ON, overriding all programs.
- VOERTUIG: The timer operates according to the programmed ON/OFF cycles.
- AF: The output is continuously OFF, overriding all programs.
Ensure the timer is set to AUTO for programmed operation.
5. Clearing Programs
To clear a specific program:
- Enter programming mode by pressing the Horlosie-ikoon button until the desired program number (e.g., "3 ON") is displayed.
- Druk die C+ button. This will clear both the ON and OFF times for that specific program.
- Repeat for other programs as needed.
- Druk HANDLEIDING om die programmeringsmodus te verlaat.
To clear all programs and reset the device, use the recessed R (Herstel) knoppie.
Onderhoud
- Maak die toestel skoon met 'n sagte, droë lap. Moenie skuurmiddels of oplosmiddels gebruik nie.
- Ensure the transparent cover is closed to protect the display and buttons from dust and splashes.
- Regularly check electrical connections for tightness, especially in high-vibration environments.
Probleemoplossing
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| Die vertoning is leeg. | Geen kragtoevoer nie; interne battery is leeg. | Check power connections (terminals 1 & 2). Ensure main power is ON. If power is present, press the R (Reset) button. The internal battery recharges when connected to power. |
| Timer not switching ON/OFF as programmed. | Incorrect program settings; timer in manual ON/OFF mode. | Verify program settings (time, day, ON/OFF). Ensure the timer is in AUTO modus deur op die te druk HANDLEIDING knoppie. |
| Connected appliance not receiving power. | Incorrect wiring; appliance fault; timer fault. | Check wiring according to Figure 2. Test the appliance directly. If wiring and appliance are fine, the timer may be faulty. |
| Buttons unresponsive or display erratic. | Software glitch; low internal battery. | Druk die ingeboude R (Reset) button. Ensure the timer has been connected to power for at least 24 hours to fully charge the internal battery. |
Beskikking
Do not dispose of this product with general household waste. This electronic device contains materials that can be recycled. Please dispose of it at a designated collection point for electrical and electronic equipment waste, in accordance with local regulations.
Waarborg en Ondersteuning
Perel products are manufactured to high quality standards. For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your local Perel distributor or retailer. Please have your model number (EDIN305N) and purchase details ready when contacting support.