This manual provides essential information for the safe and efficient operation of your ProCom ML1PHG Ventless Propane Gas Infrared Space Heater. Please read all instructions carefully before installation and use. This heater is designed to provide supplemental heat for indoor residential spaces.

ProCom ML1PHG Ventless Propane Gas Infrared Space Heater, front view.

Figure 1: ProCom ML1PHG Ventless Propane Gas Infrared Space Heater, front view.

Veiligheidsinligting

Jou veiligheid en die veiligheid van ander is baie belangrik. Hierdie handleiding bevat belangrike veiligheidsboodskappe. Lees en gehoorsaam altyd alle veiligheidsboodskappe.

  • This appliance is for use with Propane Gas only.
  • Moenie petrol of ander vlambare dampe en vloeistowwe in die omgewing van hierdie of enige ander toestel berg of gebruik nie.
  • Installation and repair must be done by a qualified service person. The appliance must be installed in accordance with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
  • This heater is equipped with an Oxygen Depletion Sensor (ODS) pilot system. The ODS will shut off the heater if oxygen levels in the room become too low. Do not tamper with the ODS.
  • Ensure adequate ventilation when operating the heater.
  • Keep combustible materials, such as furniture, drapes, and clothing, at least 3 feet (0.9 meters) away from the front of the heater.

Pakketinhoud

Verifieer dat alle komponente teenwoordig is voordat u met die installasie begin.

  • Vent Free Heater (Qty. 1)
  • Wall Mounting Bracket (Qty. 1)
  • Hardware Package (Qty. 1)

Opstelling en installasie

The ProCom ML1PHG heater can be wall-mounted using the included bracket or placed on a floor with optional base feet (sold separately).

Muurmontering

  1. Select a suitable wall location, ensuring it is away from combustible materials and has proper clearances.
  2. Attach the wall mounting bracket securely to the wall using the provided hardware. Ensure the bracket is level and firmly anchored to wall studs or appropriate anchors.
  3. Carefully lift the heater and align the mounting slots on the back of the heater with the bracket. Lower the heater onto the bracket until it is securely seated.
ProCom ML1PHG Heater mounted on a wall in a living room

Figuur 2: Example of the heater mounted on a wall.

Gas aansluiting

This heater operates on Liquid Propane (LP) gas only. A qualified technician must perform the gas connection.

  • Ensure the main gas supply valve is off before making any connections.
  • Connect the propane supply line to the heater's gas inlet. Use appropriate gas-rated sealant on all threaded connections.
  • Check all connections for leaks using a soap solution. Never use an open flame to check for leaks.
Close-up of the LP gas connection point on the heater

Figuur 3: Close-up view of the Liquid Propane (LP) gas connection point.

Bedryfsinstruksies

The ML1PHG heater features a manual control for simple operation.

Ignition Procedure

  1. Ensure the gas supply valve to the heater is open.
  2. Locate the control knob on the top of the heater.
  3. Push the control knob in and turn it counter-clockwise to the PILOT/IGN posisie.
  4. While holding the knob in, repeatedly press the ONTSTEKER button until the pilot flame ignites. You should see a small blue flame.
  5. Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up.
  6. Release the control knob. The pilot flame should remain lit. If it extinguishes, repeat steps 3-5.
  7. Once the pilot is lit, push the control knob in slightly and turn it counter-clockwise to the desired heat setting: LAAG or HOOG. The main burner will ignite.
Close-up of the control knob with Ignitor button, Pilot/Ign, Off, Low, and High settings

Figure 4: Control knob and ignitor button for operation.

Close-up of the radiant ceramic plaques glowing red when operating

Figure 5: The radiant ceramic plaques will glow red during operation.

Die verwarmer afskakel

  • To turn off the main burner, turn the control knob clockwise to the AF position. The pilot flame will also extinguish.
  • For extended periods of non-use, turn off the main gas supply valve to the heater.

Onderhoud

Gereelde onderhoud verseker die lang lewensduur en veilige werking van u verwarmer.

  • Skoonmaak: Keep the heater area clear and free from combustible materials, dust, lint, and pet hair. Use a soft, dry cloth to clean the exterior surfaces. Do not use abrasive cleaners.
  • Pilot and Burner Inspection: Periodically inspect the pilot and main burner for proper flame appearance. The pilot flame should be steady and blue. The main burner flame should be blue with no yellow tipping.
  • Ventilasie: Ensure that air openings on the heater are not obstructed.
  • Jaarlikse inspeksie: It is recommended to have the heater inspected annually by a qualified service technician.

Probleemoplossing

Verwys na die volgende tabel vir algemene probleme en hul oplossings.

ProbleemMoontlike oorsaakOplossing
Vlieënier sal nie lig nieNo gas supply; Air in gas line; Pilot orifice clogged; Thermocouple faulty; ODS activated.Ensure gas supply is on; Bleed air from line; Clean pilot orifice; Replace thermocouple; Check ventilation.
Pilot lights but main burner will not igniteControl knob not held long enough; Low gas pressure; Main burner orifice clogged.Hold knob for 30-60 seconds; Check gas supply pressure; Clean main burner orifice.
Verwarmer produseer reukNew heater burn-off; Dust accumulation; Inadequate ventilation.Operate for a few hours in a well-ventilated area; Clean heater; Increase ventilation.
Verwarmer skakel onverwags afODS activation (low oxygen); Pilot flame extinguished; Gas supply interrupted.Ensure adequate ventilation; Relight pilot; Check gas supply.

Indien die probleemoplossingstappe nie die probleem oplos nie, kontak 'n gekwalifiseerde dienstegnikus.

Spesifikasies

KenmerkDetail
HandelsmerkProCom
ModelnommerML1PHG
Brandstof tipeSlegs propaangas
Maximum BTU Output10,000 BTU
VerhittingsdekkingTot 500 XNUMX vk. Ft.
Tipe beheerManual (On/Off Settings)
OntstekingstelselPush Button Piezo Ignition
VeiligheidskenmerkeOxygen Depletion Sensor (ODS) with automatic shut-off
Elektrisiteit benodigNee
Produkafmetings (H x B x D)18.5 cm H x 24 cm B x 8 cm D
Produk Gewig13 pond.
Montage tipeWall Mount (hardware included)
UPC848660004002
Diagram showing dimensions of the ProCom ML1PHG heater: 18.5 inches high, 24 inches wide, 8 inches deep.

Figure 6: Product dimensions of the ProCom ML1PHG heater.

Waarborg inligting

This ProCom ML1PHG Ventless Propane Gas Infrared Space Heater comes with a 1 jaar beperkte waarborg from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. For full warranty details and to make a claim, please refer to the documentation included with your product or contact ProCom customer support.

Kliënte ondersteuning

For technical assistance, parts, or service inquiries, please contact ProCom customer support. Have your model number (ML1PHG) and purchase date available when contacting support.

Note: Contact information for ProCom is not provided in the product data. Please refer to the manufacturer's official website or product packaging for direct support channels.

© 2024 ProCom. Alle regte voorbehou.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.