RH Peterson FTO-24

RH Peterson Real Fyre G19A Series Foothill Oak Gas Log Set - 24 Inch Instruction Manual

Model: FTO-24

1. Inleiding

This manual provides essential instructions for the safe and proper installation, operation, and maintenance of your RH Peterson Real Fyre G19A Series Foothill Oak Gas Log Set, model FTO-24. This product is designed to enhance the aesthetic appeal of your fireplace with realistic oak log aesthetics. Please read this manual thoroughly before attempting any installation or operation.

2. Veiligheidsinligting

WAARSKUWING: Onbehoorlike installasie, aanpassing, verandering, diens of instandhouding kan beserings of skade aan eiendom veroorsaak. Verwys na hierdie handleiding. Vir bystand of bykomende inligting, raadpleeg 'n gekwalifiseerde installeerder, diensagentskap of die gasverskaffer.

  • This gas log set must be installed by a qualified professional in accordance with all local codes and the National Fuel Gas Code ANSI Z223.1/NFPA 54.
  • Verseker voldoende ventilasie in die area waar die houtstel geïnstalleer is.
  • Moenie petrol of ander vlambare dampe en vloeistowwe in die omgewing van hierdie of enige ander toestel berg of gebruik nie.
  • Hou kinders en troeteldiere weg van die warm toestel.
  • Never burn solid fuels in a fireplace equipped with a gas log set.
  • Maak altyd seker dat die kaggel damper is fully open during operation.

3. Pakketinhoud

Jou pakket moet die volgende komponente bevat:

  • Real Fyre Foothill Oak Gas Logs (various pieces)
  • Lava Granules (for burner coverage)

Let wel: The G19A Burner is required for operation and is sold separately. This log set is designed specifically for use with the G19A Burner.

4. Opstelling en installering

Installation of the gas log set requires careful placement of the logs onto the compatible G19A burner. Refer to the G19A Burner instruction manual for detailed burner installation and gas connection procedures. Ensure the burner is correctly installed and tested before placing the logs.

  1. Burner Placement: Position the G19A burner (sold separately) in your fireplace according to its specific instructions. Ensure all gas connections are secure and leak-tested by a qualified professional.
  2. Lava Granules: Distribute the provided lava granules evenly over the burner pan, ensuring not to block any burner ports or pilot light assembly. The granules help create a realistic ember bed effect.
  3. Log plasing: Carefully arrange the Foothill Oak gas logs onto the burner grate. Follow the specific log stacking pattern provided in the G19A Burner manual or a diagram if available, to ensure proper flame distribution and prevent sooting. Incorrect log placement can affect performance and safety.
  4. Finale kontrole: After log placement, ensure no logs are directly blocking the pilot light or any burner ports. There should be adequate space for flames to develop naturally.
Real Fyre G19A Series Foothill Oak Gas Log Set with flames

An image showing the Real Fyre G19A Series Foothill Oak Gas Log Set installed, with realistic flames emanating from the base, surrounded by dark lava rocks. This illustrates the typical appearance of the log set in operation.

5. Bedryfsinstruksies

Refer to the G19A Burner instruction manual for specific lighting and operating procedures. General steps include:

  1. Voor beligting: Ensure the fireplace damper is fully open. Check for any obstructions in the fireplace or around the log set.
  2. Verlig die vlieënier: Follow the instructions in your G19A burner manual to light the pilot light.
  3. Igniting Main Burner: Once the pilot is lit, turn the main gas valve to the "ON" position. The main burner should ignite. Adjust the flame height as desired using the control knob.
  4. Af skakel: To turn off, turn the main gas valve to the "OFF" position. The pilot light may remain lit, depending on your burner model. If you wish to turn off the pilot, follow the instructions in your burner manual.

Belangrik: Never leave the appliance unattended while operating. Allow the log set to cool completely before handling.

6. Onderhoud

Regular maintenance ensures the longevity and safe operation of your gas log set.

  • Skoonmaak: Periodically, when the logs are completely cool, gently brush off any dust or soot accumulation. Use a soft brush; do not use abrasive cleaners or water directly on the logs.
  • Inspeksie: Annually, or more frequently if used often, inspect the logs for any signs of cracking or deterioration. Inspect the burner and gas connections for leaks or damage.
  • Professionele diens: It is recommended to have your gas log set and burner inspected by a qualified service technician at least once a year.

7. Probleemoplossing

If you encounter issues, refer to the troubleshooting section of your G19A Burner manual first, as most operational problems relate to the burner system. Common issues related to the log set itself are rare but can include:

  • Excessive Sooting: This can be caused by incorrect log placement, a dirty burner, or improper gas pressure. Review log placement according to the burner manual. Clean the burner if necessary. Consult a professional if the issue persists.
  • Logs Appear Damaged: If logs show signs of significant cracking or breakage, they may need replacement. Contact RH Peterson customer support or your dealer.

For any issues not resolved by these steps, contact a qualified service technician.

8. Spesifikasies

KenmerkDetail
HandelsmerkRH Peterson
ModelnommerFTO-24
Produk afmetings38 x 17.5 x 9.5 duim
Item gewig57.5 pond
MateriaalSuperior Refractory Ceramics (designed for high temperatures, with realistic oak wood appearance)
VersterkingSteel Rods inserted in each Log (for maximum reinforcement)
Required BurnerG19A Burner (Sold Separately)
UPC619655182735

9. Waarborginligting

Specific warranty details for the RH Peterson Real Fyre G19A Series Foothill Oak Gas Log Set are not provided in this document. Please refer to the warranty information included with your G19A Burner or contact RH Peterson customer service or your authorized dealer for comprehensive warranty terms and conditions.

10. Kliëntediens

For technical assistance, replacement parts, or further inquiries regarding your RH Peterson Real Fyre G19A Series Foothill Oak Gas Log Set, please contact your authorized RH Peterson dealer or visit the official RH Peterson website for customer service contact information. Always provide your model number (FTO-24) when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.