The Rinnai EX17CTP Direct Vent Wall Furnace is designed to provide efficient and consistent heating for indoor spaces. This unit features stainless steel bunsen burners, a warm air outlet with forced combustion and convection through bottom front louvers, and an enameled tray humidifier. It is suitable for homes, apartments, condominiums, and commercial settings, and is approved for modular/mobile home use.

Key features include an electronic spark ignition, a seven-stage modulating gas valve, timer settings, a variable speed inducer motor with pressure switch, and an electronic thermostat with a temperature range of 60°F to 80°F. For safety, it incorporates a child lock and self-diagnostic electronics that monitor functions, provide auto shutdown codes, and automatically restart if ignition or combustion fails.

Video: Rotational view of the Rinnai EX17CTP Wall Furnace, highlighting its exterior design and compact form factor.

Video: Verbyview of Rinnai's features and benefits, including energy efficiency and heating performance.

2. Opstelling en installering

The Rinnai EX17CTP is designed for indoor installation only and requires direct venting. Professional installation by a qualified technician is highly recommended to ensure proper and safe operation, as well as compliance with local codes and regulations.

2.1 Uitpak en inspeksie

Carefully unpack the unit and inspect it for any shipping damage. Report any damage immediately to your dealer or installer.

2.2 Liggingvereistes

  • Ensure the installation location allows for proper direct venting to the outside.
  • Maintain adequate clearances from combustible materials as specified in the installation manual.
  • The unit is wall-mounted; ensure the wall structure can support the unit's weight (57 lbs).
  • The unit requires a standard electrical outlet for its electronic spark ignition and fan operation.

2.3 Gasaansluiting

Connect the unit to a propane gas supply. All gas connections must be performed by a licensed professional.

2.4 Ontlugting

The direct vent system draws combustion air from outside and exhausts combustion by-products outside, ensuring safe indoor air quality. Follow the detailed instructions in the separate installation manual for proper venting.

Rinnai EX17CTP Space Heater Wall Furnace

Beeld: Voorkant view of the Rinnai EX17CTP Direct Vent Wall Furnace.

3. Bedryfsinstruksies

The Rinnai EX17CTP features a user-friendly control panel for easy operation.

3.1 Krag aan/af

  • Druk die Aan/Af knoppie om die eenheid aan of af te skakel.

3.2 Stel temperatuur

  • Gebruik die Temp Up/Down arrows to adjust the desired room temperature. The thermostat range is 60°F to 80°F.
  • The unit will automatically modulate its heat output to maintain the set temperature.

3.3 Timer-instellings

  • The unit includes programmable timer settings (Timer 1, Timer 2) to schedule heating cycles. Refer to the detailed programming section in the full manual for specific instructions.

3.4 Kinderslot

  • Aktiveer die Sluit function to prevent unintended changes to settings, especially useful in households with children.

3.5 Ekonomie-modus

  • Betrek Ekonomie mode to optimize energy consumption. In this mode, the unit allows the temperature to drop by a few degrees before actively heating, reducing continuous operation.

4. Onderhoud

Regular maintenance ensures the longevity and efficient operation of your Rinnai EX17CTP furnace.

4.1 Filter Skoonmaak

The unit is equipped with a mesh filter that collects dust and debris. A 'Filter' indicator light on the control panel will illuminate when cleaning is required.

  • Turn off the unit before attempting to clean the filter.
  • Locate the filter access panel, typically at the top or front of the unit.
  • Gently pull out the mesh filter.
  • Clean the filter by rinsing it with water or vacuuming off accumulated dust and lint. Ensure it is completely dry before reinserting.
  • Reinsert the filter and close the access panel. Turn the unit back on.
Rinnai EX17CTP with feature icons

Image: Diagram illustrating key features of the Rinnai EnergySaver Direct Vent Wall Furnace, including indoor installation, consistent heating, user-friendly control panel, wall thermostat compatibility, high altitude approval, modulating technology with convection fan, and warranty details.

4.2 Jaarlikse inspeksie

It is recommended to have a qualified service technician inspect the unit annually to ensure all components are functioning correctly and safely.

5. Probleemoplossing

The Rinnai EX17CTP features self-diagnostic electronics. If an issue occurs, the unit may display an error code or shut down automatically.

  • No Heat/Unit Not Turning On: Check the power supply and gas connection. Ensure the unit is switched on and the thermostat is set above the current room temperature.
  • Filter Light On: Maak die lugfilter skoon soos beskryf in die Onderhoud-afdeling.
  • Ongewone geluide: While the unit is designed for quiet operation, any new or loud noises should be investigated. Ensure the fan is not obstructed.
  • Foutkodes: If an error code appears on the display, consult the detailed troubleshooting guide in the full product manual or contact Rinnai customer support.

Vir aanhoudende probleme, kontak 'n gekwalifiseerde diens tegnikus.

6. Spesifikasies

KenmerkSpesifikasie
HandelsmerkRinnai
ModelnommerEX17CTP
Brandstof tipePropaan
Hitte-uitset10 000 Britse Termiese Eenhede (BTU)
Verhittingsdekking340-354 vierkante voet
Minimum temperatuur instelling60°F
Maksimum temperatuur instelling80°F
KragbronCorded Electric, Gas Powered
VormfaktorMuur gemonteer
Binne/buiteluggebruikBinneshuise
Item gewig57 pond
UPC766156009860
Rinnai EX17CTP Product Dimensions and Specifications

Image: Detailed product specifications for the Rinnai EX17CTP, including depth, height, width, weight, gas type, installation type, power consumption, noise level, altitude approval, wall thermostat compatibility, and warranty.

Rinnai EnergySaver Direct Vent Wall Furnace Model Comparison

Image: Comparison table of various Rinnai EnergySaver Direct Vent Wall Furnace models (EX08CT, EX11CT, EX17CT, EX22CT, EX38CT), showing differences in gas type, fan CFM output, power consumption, noise level, and BTU range. The EX17CTP is highlighted.

National Heat Zones and Heating Area Size for Rinnai EX17CTP

Image: Map of National Heat Zones with a table indicating recommended cubic feet and square feet heating area for the EX17CTP model across different zones.

Comparison of Rinnai EX17CTP and EX17DTP models

Image: Side-by-side comparison of the Rinnai EX17CTP and EX17DTP models, detailing similarities in power consumption, length x width x height, and noise level, and differences in weight.

7. Waarborg en Ondersteuning

7.1 Waarborginligting

Rinnai products are built to high standards. The EX17CTP typically includes a residential warranty:

  • Hitteruiler: 10 Jaar
  • Arbeid: 2 Jaar
  • Onderdele: 5 Jaar

*Terms & Conditions may apply. Please refer to your product registration or Rinnai's official webwebwerf vir volledige waarborgbesonderhede.

7.2 Kliëntediens

For technical assistance, troubleshooting, or warranty claims, please contact Rinnai Customer Support. High-quality, safe, and efficient appliances are a priority for Rinnai, and their customer support is available to assist you.

Jy kan besoek die Rinnai Store on Amazon for more information or to explore other Rinnai products.

© 2026 Rinnai America Corporation. All rights reserved.

Hierdie handleiding is slegs vir inligtingsdoeleindes. Raadpleeg altyd 'n gekwalifiseerde professionele persoon vir installasie en diens.