Inleiding
This manual provides detailed instructions for the installation, operation, and maintenance of the Paradox VDMP3 Voice Dialer Module. The VDMP3 module integrates with compatible Paradox alarm systems, including SPECTRA SP, MG5000/MG5050, and DIGIPLEX EVO series, to provide voice reporting capabilities for alarm events. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.
Veiligheidsinligting
- Installasie moet slegs deur gekwalifiseerde personeel uitgevoer word.
- Disconnect power to the alarm system before installing or servicing the module.
- Ensure all connections are secure and correct to prevent damage or malfunction.
- Moenie die module blootstel aan vog, uiterste temperature of korrosiewe omgewings nie.
- Refer to the main alarm system manual for additional safety guidelines.
The VDMP3 module is designed for indoor use only.
Pakketinhoud
Verifieer dat alle items in die pakket teenwoordig is:
- Paradox VDMP3 Voice Dialer Module
- Verbindingskabel
- This User Manual (or quick start guide)
Indien enige items ontbreek of beskadig is, kontak u verskaffer onmiddellik.
Installasie en opstelling
1. Fisiese installasie
- Power down the main alarm control panel.
- Locate the expansion bus connector on the control panel.
- Connect the VDMP3 module to the expansion bus using the provided cable. Ensure correct polarity if applicable.
- Secure the VDMP3 module within the alarm panel enclosure or in a suitable, protected location.
- Power up the main alarm control panel.
2. Programmering
The VDMP3 module requires programming via the alarm system's keypad or Paradox Babyware software. Refer to your main alarm system's programming guide for specific instructions. Key programming steps include:
- Enabling the VDMP3 module in the system.
- Configuring phone numbers for voice reporting.
- Assigning voice messages to specific zones or events.
- Setting up reporting options (e.g., number of rings, call attempts).
Let wel: The module may require a language update depending on its origin. This typically requires the Babyware software and a compatible EVO series alarm panel for flashing.

Image: The Paradox VDMP3 Voice Dialer Module. This image shows the compact module, typically installed inside the main alarm control panel, connecting via a ribbon cable to the system's expansion bus.
Bedryfsinstruksies
Once installed and programmed, the VDMP3 module operates automatically in conjunction with your Paradox alarm system.
Voice Reporting
Upon an alarm event (e.g., zone violation, panic alarm), the VDMP3 module will:
- Dial the pre-programmed phone numbers in sequence.
- Play the assigned voice message to the recipient.
- Wait for acknowledgment (if configured) or proceed to the next number/attempt.
Remote Control (if configured)
Depending on your system's configuration, you may be able to remotely arm/disarm the system or control PGM outputs by calling the VDMP3 module and entering specific codes via your phone's keypad. Refer to your alarm system's manual for remote control codes and functionality.
Onderhoud
- The VDMP3 module requires minimal maintenance.
- Periodically test the voice reporting function by triggering a test alarm to ensure calls are made and messages are clear.
- Keep the alarm system's firmware updated as recommended by Paradox.
- Maak seker dat die module vry is van stof en puin.
Do not attempt to repair the module yourself. Contact qualified service personnel for any issues.
Probleemoplossing
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| Module not recognized by panel. | Incorrect connection; module not enabled in programming; faulty module. | Check wiring; enable module in panel programming; contact support. |
| No voice calls on alarm. | Incorrect phone numbers programmed; voice messages not assigned; phone line issue; module not enabled. | Verify programming of phone numbers and messages; check phone line connection; ensure module is enabled. |
| Voice messages are unclear or in wrong language. | Language pack issue; corrupted voice data. | Re-flash module with correct language pack using Babyware (requires EVO panel); contact support. |
Spesifikasies
- Model: VDMP3
- Verenigbaarheid: Paradox SPECTRA SP, MG5000/MG5050, DIGIPLEX EVO series alarm systems
- Afmetings: Ongeveer 9.4 x 6.8 x 2.8 cm (3.7 x 2.7 x 1.1 duim)
- Gewig: Ongeveer 40 g (1.4 onse)
- Krag: Supplied by alarm control panel
- Bedryfsomgewing: Slegs binnenshuise gebruik
Spesifikasies is onderhewig aan verandering sonder kennisgewing.
Waarborg en Ondersteuning
Paradox products are covered by a limited warranty. For specific warranty terms and conditions, please refer to the warranty statement provided with your original purchase or visit the official Paradox webwebwerf.
For technical support, programming assistance, or service, please contact your authorized Paradox dealer or installer. Do not attempt to service the unit yourself.
Vervaardiger: PARADOKS