Alphacool 13305

Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo User Manual

Model: 13305

1. Inleiding

This manual provides essential information for the proper installation, operation, and maintenance of your Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo. Please read this manual thoroughly before beginning installation to ensure safe and efficient use of the product.

Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo

Figure 1: Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo, showing the pump unit integrated into the acetal reservoir top.

2. Veiligheidsinligting

  • Vloeistofversoenbaarheid: Use only clear, transparent water cooling fluids. Fluids containing particles or additives (e.g., Pastel fluids) can clog and permanently damage water cooling components such as radiators, pumps, and blocks. Use of such fluids may void the manufacturer's warranty.
  • Impeller Handling: Removing the impeller from the ceramic shaft will cause the upper ceramic clamping ring to over-expand, leading to its destruction. This action will void the pump's warranty. If the pump is reassembled after such removal, the clamping ring will loosen, which is not accepted as grounds for return or exchange.
  • Voltage: Verseker die kragtoevoer voltage is within the permitted range of 8-13V DC.
  • Temperatuur: Do not exceed the maximum system temperature of 65°C.

3. Pakketinhoud

Die volgende items is ingesluit in die omvang van aflewering:

  • 1x Alphacool Eispumpe VPP755 - G1/4 IT
  • 1x Eisdecke D5 - Acetal V.3

4. Opstelling en installering

4.1 Fisiese installasie

The pump/res combo can be mounted using the integrated brackets. Ensure stable placement within your system to prevent vibration and stress on connections.

Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo with mounting brackets

Figuur 2: Kant view of the pump/res combo, illustrating the mounting brackets for secure installation.

4.2 Poortverbindings

The Eisdecke D5 V.3 features multiple G1/4" threads for flexible integration into your water cooling loop. Identify the IN (inlet) and OUT (outlet) ports as labeled on the unit for correct flow direction.

Top view of Alphacool Eisdecke D5 V.3 showing G1/4 inch ports

Figuur 3: Bo view of the Eisdecke D5 V.3, highlighting the G1/4" inlet (IN) and outlet (OUT) ports for tubing connections.

4.3 Elektriese verbindings

Connect the pump to your power supply and motherboard using the provided cables:

  • 4-pin Molex: For main power supply to the pump.
  • 3-pin Tach Signal: Connect to a motherboard fan header to monitor pump RPM.
  • 4-pin PWM Signal: Connect to a motherboard PWM fan header for speed control.
Alphacool Eispumpe VPP755 power and signal cables

Figure 4: The power and signal cables for the VPP755 pump, including the 4-pin Molex, 3-pin tachometer, and 4-pin PWM connectors.

5. Bedryfsinstruksies

The Alphacool Eispumpe VPP755 features an adjustable speed setting, allowing you to optimize performance and noise levels for your specific cooling needs.

5.1 verstelbare vlakke

The pump can be adjusted in five distinct levels, controlling the rotational speed (RPM):

  • Vlak 1: 1800 RPM
  • Vlak 2: 2500 RPM
  • Vlak 3: 3200 RPM
  • Vlak 4: 3900 RPM
  • Vlak 5: 4500 RPM

Adjust the level according to your system's cooling requirements and desired noise profile. Higher levels provide greater flow rate and pressure.

6. Onderhoud

Regular maintenance is crucial for the longevity and performance of your water cooling system. Ensure to use only clear, transparent water cooling fluids. Avoid fluids with particles or additives, as they can cause blockages and damage to the pump and other components. Periodically inspect your loop for any signs of debris or fluid discoloration.

7. Probleemoplossing

If you experience issues with your pump, consider the following:

  • No Power/No Operation: Check all electrical connections (4-pin Molex, 3-pin tach, 4-pin PWM) to ensure they are securely seated and receiving power. Verify your power supply is functioning correctly.
  • Reduced Flow/Noise: This could indicate air in the loop or a blockage. Bleed the system thoroughly to remove air. If using non-compatible fluids, a blockage may have occurred.
  • Impeller Issues: As stated in the safety information, do not attempt to remove the impeller from the ceramic shaft. Doing so will damage the clamping ring and void the warranty. If the pump exhibits unusual noises or performance issues after unauthorized disassembly, it is likely damaged beyond repair and not covered by warranty.

8. Tegniese spesifikasies

8.1 VPP755 Eispumpe

KenmerkSpesifikasie
Dimensions (DxH)60 x 53.5 mm
Kabellengte50 cm
Standaard Voltage12V GS
Kragverbruik14 W
Permitted Voltage8-13V DC
Pressure at 12V4m water head
Maksimum vloeitempo350 l/h
Pump MediumWater, water/glycol mixture
Maximum System Temperature65°C
Kragverbinding4-pen Molex
Tach Signal3-pen
PWM sein4-pen
Verstelbare vlakke5 levels (1800-4500 RPM)

8.2 Eisdecke D5 V.3

KenmerkSpesifikasie
Afmetings80 x 80 x 40 mm
Dimensions with Stands83 x 80 x 87 mm
MateriaalAsetaal
Verbindings5x 1/4" threads
Dimensional drawing of Alphacool Eispumpe VPP755 with Eisdecke D5 V.3

Figure 5: Dimensional drawing of the Alphacool Eispumpe VPP755 with Eisdecke D5 V.3, showing key measurements for integration.

9. Waarborg en Ondersteuning

The manufacturer's warranty for the Alphacool Eispumpe VPP755 with Eisdecke D5 V.3 Pump/Res Combo is subject to specific conditions. Please note the following:

  • Impeller Removal: Any attempt to remove the impeller from the ceramic shaft will result in damage to the internal clamping ring and will immediately void the pump's warranty.
  • Vloeistofgebruik: Use of non-compatible fluids, particularly those containing particles or additives (e.g., Pastel fluids), can cause permanent damage to the pump and other water cooling components, potentially voiding the manufacturer's warranty.

For technical support or warranty inquiries, please refer to the official Alphacool website or contact their customer service directly. Always provide your product model number (13305) and proof of purchase when seeking support.

Verwante Dokumente - 13305

Preview Alphacool EisPumpe-VPP755 Water Cooling Pump: Installation, Operation, and Safety Guide
Comprehensive guide for the Alphacool EisPumpe-VPP755 water cooling pump, covering installation, electrical connections, manual and PWM speed control, technical specifications, safety instructions, and warranty details.
Preview Alphacool Core Plat Reservoir 240 Regs met VPP Pomp - Tegniese Spesifikasies
Verken die Alphacool Core Flat Reservoir 240 Right, met 'n geïntegreerde VPP-pomp, digitale aRGB-beligting en 'n plat akrielontwerp, ideaal vir persoonlike rekenaarwaterverkoeling en kompakte bouwerk. Sluit 5 verbindings in vir buigsame opstelling.
Preview Alphacool Eisdecke Pump Top Installation and Technical Details
Comprehensive guide to the Alphacool Eisdecke pump top, covering installation, technical specifications, and safety instructions in multiple languages.
Preview Alphacool Core Flat Reservoir Series User Manual
Installation and setup guide for the Alphacool Core Flat Reservoir Series, including pump installation, mounting instructions, and maintenance.
Preview Bitspower Premium Cubiod Reservoir 150 (D5) Installation Guide
Comprehensive installation guide for the Bitspower Premium Cubiod Reservoir 150 (D5). Learn about component identification, specifications, assembly steps, and important warnings for setting up your PC liquid cooling system.