BEST LEDR-1

BEST LEDR-1 LED Emergency Light User Manual

Model: LEDR-1

1. Inleiding

This manual provides essential instructions for the safe installation, operation, and maintenance of your BEST LEDR-1 LED Emergency Light. Please read this manual thoroughly before installation and retain it for future reference. The LEDR-1 is designed to provide reliable emergency illumination during power outages, ensuring safety in commercial and residential environments.

2. Belangrike veiligheidsinstruksies

WAARSKUWING: Risiko van elektriese skok. Ontkoppel die krag voor installasie of onderhoud.

  • Alle dienswerk moet slegs deur gekwalifiseerde personeel uitgevoer word.
  • Moenie naby gas- of elektriese verwarmers monteer nie.
  • Ensure the electrical wiring is properly grounded.
  • Do not use outdoors. This unit is designed for indoor use only.
  • Moenie toelaat dat kragtoevoerdrade warm oppervlaktes raak nie.
  • Mount the unit in locations and at heights where it will not be subjected to tampering deur ongemagtigde personeel.
  • Die gebruik van bykomstighede wat nie deur die vervaardiger aanbeveel word nie, kan 'n onveilige toestand veroorsaak.
  • Moenie hierdie toerusting vir ander as die beoogde gebruik gebruik nie.
  • Allow battery to charge for a minimum of 24 hours after installation before testing.

3. Pakketinhoud

Verifieer dat alle komponente teenwoordig en onbeskadig is wanneer die verpakking oopgemaak word:

  • BEST LEDR-1 LED Emergency Light Fixture (1 unit)
  • Monteringshardeware (skroewe, ankers)
  • Draadmoere
  • Gebruikershandleiding (hierdie dokument)
  • AA NiCAD Battery (pre-installed or included separately)

4. Produk verbyview

The BEST LEDR-1 is a compact and efficient LED emergency light designed for wall-mount applications. It features a durable white thermoplastic housing and two adjustable LED lamp heads, providing 98 lumens of bright, white light (5000 Kelvin) during emergency situations. The unit operates on 120 Volts AC and includes a rechargeable NiCAD battery for backup power.

BEST LEDR-1 Emergency Light, front view

Figuur 1: Voorkant view of the BEST LEDR-1 Emergency Light. This image shows the compact white thermoplastic housing with two adjustable LED lamp koppe.

Sleutel kenmerke:

  • Behuising: White Thermoplastic
  • Ligbron: 2 LED heads
  • Voltage: 120 Volt AC
  • Battery: NiCAD, 90 minutes average life
  • Lig uitset: 98 Lumen
  • Afmetings: Approximately 14.75" L x 3.75" W x 3.75" H

5. Installasie

The LEDR-1 is designed for flush wall mounting. Follow these steps for proper installation:

  1. Kragontkoppeling: Before beginning any installation, ensure that the main power supply to the circuit where the emergency light will be installed is turned OFF at the circuit breaker or fuse box.
  2. Monteerplek: Select a suitable wall location for mounting. The unit should be mounted at a height and in a position that allows for optimal light distribution during an emergency. Ensure the mounting surface is solid and can support the fixture's weight.
  3. Berei montage-oppervlak voor: Use the provided mounting hardware (screws and anchors) to secure the mounting plate or backplate of the emergency light to the wall. If the unit has a separate mounting plate, attach it first.
  4. Bedrading verbindings:
    • Koppel die swart draad from the emergency light to the hot (live) wire from the building's electrical supply.
    • Koppel die wit draad from the emergency light to the neutrale draad from the building's electrical supply.
    • Koppel die groen draad from the emergency light to the gronddraad from the building's electrical supply.
    • Gebruik die meegeleverde draadmoere om alle verbindings vas te maak. Maak seker dat alle verbindings styf en behoorlik geïsoleer is.
  5. Batteryverbinding: If the battery is not pre-connected, connect the battery pack to the circuit board. Ensure correct polarity.
  6. Veilige toebehore: Carefully tuck all wires into the junction box or fixture housing. Secure the emergency light fixture to the mounting plate or wall according to the specific design of the unit.
  7. Herstel krag: Once the installation is complete and all connections are secure, restore power to the circuit. The CHARGE INDICATOR light on the unit should illuminate, indicating that the battery is charging.
  8. Aanvanklike heffing: Allow the battery to charge for a minimum of 24 hours before performing the first test.

6. Operasie

The BEST LEDR-1 Emergency Light operates automatically:

  • AC Power On: When AC power is supplied to the unit, the charge indicator light will be ON, and the battery will be charging. The LED lamp heads will remain OFF.
  • Krag Outage: In the event of an AC power failure, the emergency light will automatically switch to battery backup mode, and the LED lamp heads will illuminate. The unit will provide emergency lighting for approximately 90 minutes.
  • AC Power Restored: When AC power is restored, the LED lamp heads will turn OFF, and the unit will revert to charging the battery.
  • Toetsknoppie: A test button is located on the unit. Pressing this button simulates an AC power failure, allowing you to verify that the emergency lights function correctly. Release the button to return to normal operation.
  • Verstelbare Lamp Koppe: The two LED lamp heads can be manually adjusted to direct light to desired areas.

7. Onderhoud

Regular maintenance ensures the longevity and reliability of your emergency light.

Battery toets:

Perform the following tests according to local codes and regulations (typically monthly and annually):

  • Maandelikse Toets: Press and hold the test button for at least 30 seconds. The LED lamp heads should illuminate. Release the button; the lights should turn off, and the charge indicator should be ON.
  • Annual Test: Disconnect AC power to the unit for a full 90 minutes. The LED lamp heads should remain illuminated for the entire duration. Reconnect AC power; the lights should turn off, and the charge indicator should be ON. If the unit fails to operate for the full 90 minutes, the battery may need replacement.

Skoonmaak:

Clean the exterior of the unit and lamp heads periodically with a soft, damp lap. Moenie skuur skoonmaakmiddels of oplosmiddels gebruik nie.

Battery vervanging:

The NiCAD battery has a limited lifespan. If the unit fails the annual 90-minute test, the battery likely needs replacement. Contact a qualified electrician or the manufacturer for battery replacement instructions and compatible battery types.

8. Probleemoplossing

ProbleemMoontlike oorsaakOplossing
Emergency lights do not turn ON during power outage or when test button is pressed.
  • No AC power to the unit.
  • Battery not connected or faulty.
  • Battery nie ten volle gelaai nie.
  • Foutiewe LED lamp koppe.
  • Kontroleer stroombreker en bedradingsverbindings.
  • Ensure battery is properly connected. Allow 24 hours for initial charge.
  • Perform a 90-minute discharge test after 24-hour charge. Replace battery if necessary.
  • Kontak gekwalifiseerde dienspersoneel.
Charge indicator light is OFF when AC power is present.
  • No AC power to the unit.
  • Faulty charge indicator LED.
  • Interne stroombaan fout.
  • Kontroleer stroombreker en bedradingsverbindings.
  • Kontak gekwalifiseerde dienspersoneel.
Emergency lights do not stay ON for 90 minutes during annual test.
  • Die battery het die einde van sy lewensduur bereik.
  • Battery nie ten volle gelaai nie.
  • Vervang die battery.
  • Ensure unit has been connected to AC power for at least 24 hours prior to test.

9. Spesifikasies

KenmerkDetail
ModelnommerLEDR-1
HandelsmerkBESTE
BehuisingsmateriaalWhite Thermoplastic
LigbrontipeLED (2 heads)
Voltage120 Volt AC
Wattage2 watt
Helderheid98 Lumen
Doeltreffendheid49 lumen/watt
Kleur temperatuur5000 Kelvin
Battery TipeNiCAD (1 AA battery required, included)
Average Battery Life (Emergency Mode)90 minute
Installasie tipeFlush Wall Mount
Binne/buiteluggebruikSlegs binnenshuis
Produkafmetings (L x B x H)14.75" x 3.75" x 3.75"
Item gewig0.01 ons
Beheer metodeRemote (Test Button)

10. Waarborg en Ondersteuning

The BEST LEDR-1 LED Emergency Light comes with a full manufacturer warranty. For specific warranty details, claims, or technical support, please refer to the warranty card included with your product or contact Best Lighting Products directly. Keep your purchase receipt as proof of purchase.

For assistance, please contact Best Lighting Products customer service.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.