Jumper Medical JPD-FR301

Jumper Medical Infrared Ear Thermometer

Model: JPD-FR301 User Manual

1. Inleiding

This user manual provides detailed instructions for the safe and effective operation of your Jumper Medical Infrared Ear Thermometer, Model JPD-FR301. This device is designed for accurate body temperature measurement in the ear canal for all ages, including infants, children, and adults.

Lees asseblief hierdie handleiding deeglik deur voor die eerste gebruik en bewaar dit vir toekomstige verwysing.

2. Produkkenmerke

  • Digital Infrared (IR) Ear Thermometer with protective cap.
  • Fast 1-second measurement for quick results.
  • Acoustic fever alarm for elevated temperatures (> 37.5 °C).
  • Memory storage for the last 20 measurement readings.
  • Wisselbare temperatuurvertoning tussen Celsius (°C) en Fahrenheit (°F).
  • Ergonomic design for comfortable handling and use.
  • High sensitivity for maximum precision.
  • Meets high hygienic standards.
  • Certified with CE, FDA, ISO 13485 + AC:2012, ISO 10993-1, ISO 10993-10, Norm IEC 60601-1-2, and conforms to the Medical Devices Directive - MDD (EU).
Jumper Medical Infrared Ear Thermometer in hand, demonstrating its ergonomic design and display.

Figuur 2.1: The Jumper Medical Infrared Ear Thermometer held in a hand, showcasing its ergonomic shape and the clear LCD display.

3. Get to Know Your Product (Components)

Detailed diagram of the Jumper Medical JPD-FR301 thermometer, labeling its parts including the measuring button, LCD display, sensor, battery cover, ear cap case, and disposable ear caps.

Figuur 3.1: Labeled diagram of the JPD-FR301 thermometer components.

  1. Meet knoppie: Used to initiate a temperature measurement.
  2. LCD-skerm: Shows temperature readings, mode indicators, and battery status.
  3. Sensor: The infrared sensor located at the tip for accurate ear temperature detection.
  4. Batteryklep: Protects the battery compartment.
  5. Ear cap case: Storage for disposable ear caps.
  6. Disposable ear caps: Hygienic covers for the sensor.
  7. Boonste deksel: Part of the ear cap case.
  8. Agterblad: Part of the ear cap case.

4. Verpakkingsinhoud

Nadat u die pakkie oopgemaak het, maak asseblief seker dat al die items wat hieronder gelys word, teenwoordig en in 'n goeie toestand is:

  • Jumper Medical Infrared Ear Thermometer unit (JPD-FR301)
  • Pouch or storage bag
  • Ear cap case with disposable ear caps
  • 2 pcs of AAA battery
All items included in the Jumper Medical Infrared Ear Thermometer package: the thermometer, a soft pink storage pouch, the ear cap dispenser, and two AAA batteries.

Figuur 4.1: All items included in the product packaging.

5. Opstelling

5.1 Battery installasie

The thermometer requires 2 AAA batteries for operation. To install or replace batteries:

  1. Locate the battery cover (4) on the back of the thermometer.
  2. Skuif die batterydeksel oop.
  3. Plaas twee AAA-batterye in en maak seker dat die polariteit (+ en -) korrek is soos aangedui in die kompartement.
  4. Maak die batteryklep stewig toe totdat dit in plek klik.

5.2 Attaching/Using Ear Cap Case

The ear cap case (5) holds disposable ear caps (6) for hygienic use. Always use a new, undamaged ear cap for each measurement.

Series of images demonstrating how to open the Jumper Medical ear cap case, insert disposable ear caps, and attach the case to the thermometer.

Figuur 5.1: Steps for handling the ear cap case and disposable ear caps.

  1. To open the ear cap case, gently lift the top cover (7) or slide the rear cover (8).
  2. Take out a disposable ear cap.
  3. Carefully place the ear cap onto the sensor (3) of the thermometer until it is securely fitted.
  4. After use, dispose of the used ear cap properly.

6. Bedryfsinstruksies

6.1 Neem 'n meting

  1. Ensure a new, clean disposable ear cap is securely attached to the sensor.
  2. Press the "START" (Measuring button 1) to turn on the thermometer. The display will show the last measurement or a standby indicator.
  3. Gently insert the sensor tip with the ear cap into the ear canal. For accurate readings, ensure the tip is pointing towards the eardrum.
  4. Press the "START" button again to initiate the measurement.
  5. The measurement will be completed in approximately 1 second, and the result will be displayed on the LCD (2).
  6. If the temperature is elevated (fever alarm), an audible alert will sound.
  7. Die termometer sal die lesing outomaties in sy geheue stoor.
  8. Remove the thermometer from the ear and dispose of the used ear cap.

6.2 Switching Between °C and °F

To switch the temperature unit between Celsius (°C) and Fahrenheit (°F):

  • With the thermometer turned off, press and hold the "START" button for approximately 5 seconds until the unit changes on the display.
  • Release the button. The new unit will be set for future measurements.

6.3 Geheueherroeping

The thermometer stores the last 20 measurement readings. To recall them:

  • Skakel die termometer aan.
  • Briefly press the "START" button repeatedly to cycle through the stored readings. Each press will display the next previous reading.

7. Onderhoud

7.1 Skoonmaak van die termometer

  • Always clean the thermometer after each use, especially the sensor area.
  • Gebruik 'n sagte lap liggies dampened with 70% isopropyl alcohol to wipe the sensor and the body of the thermometer.
  • Moenie die termometer in water of enige ander vloeistof dompel nie.
  • Allow the thermometer to air dry completely before storing.
  • Moenie skuur skoonmaakmiddels of harde chemikalieë gebruik nie.

7.2 Berging

Store the thermometer in its original pouch or the ear cap case in a cool, dry place, away from direct sunlight and extreme temperatures.

If the thermometer will not be used for an extended period, remove the batteries to prevent leakage and damage.

7.3 Bedryfs- en bergingsvoorwaardes

Infographic detailing the recommended operating and storage environmental conditions for the Jumper Medical thermometer, including temperature, atmospheric pressure, and humidity ranges.

Figuur 7.1: Recommended environmental conditions for operation and storage.

Operating Environment Conditions:

  • Temperatuur: +10°C ~ +40°C (50°F ~ 104°F)
  • Atmosferiese druk: 86 kPa ~ 106 kPa
  • Humiditeit: 15-85% RH, nie-kondenserend

Storage & Transportation Conditions:

  • Temperatuur: -10 ° C ~ + 50 ° C (14 ° F ~ 122 ° F)
  • Atmosferiese druk: 50 kPa ~ 106 kPa
  • Humiditeit: <93% RH, nie-kondenserend

8. Probleemoplossing

ProbleemMoontlike oorsaakOplossing
Termometer skakel nie aan nie.Batterye is pap of verkeerd geplaas.Vervang batterye met nuwe AAA-batterye en maak seker dat die polariteit korrek is.
Onakkurate lesings.Used or damaged ear cap; sensor dirty; improper insertion into ear canal; extreme environmental conditions.Use a new, clean ear cap. Clean the sensor. Ensure correct insertion. Operate within specified temperature and humidity ranges.
"Laag" of "Hi" word vertoon.Temperatuur is buite die meetbare reeks.Ensure the thermometer is used in the correct operating temperature range and the subject's temperature is within human body temperature limits.
Fever alarm sounds frequently.Subject's temperature is consistently above 37.5 °C (99.5 °F).This indicates an elevated temperature. Consult a medical professional if fever persists.

9. Spesifikasies

KenmerkDetail
Model:JPD-FR301
Produk Tipe:Infrarooi oortermometer
Kragbron:2 x AAA Batteries (Battery-operated)
Meting Tyd:1 sekondes
Geheue kapasiteit:20 XNUMX lesings
Temperatuur Eenhede:Celsius (°C) / Fahrenheit (°F) omskakelbaar
Materiaal:Plastiek
Ouderdomsreeks:Child and Adult
UPC:635833227234
Sertifiserings:CE, FDA, ISO 13485 + AC:2012, ISO 10993-1, ISO 10993-10, Norm IEC 60601-1-2, MDD (EU)
Verpakking Afmetings:19.4 x 13.2 x 6.4 cm
Gewig:300 Grams (packaged)

10. Waarborg en Ondersteuning

For warranty information or technical support, please refer to the warranty card included in your product packaging or contact Jumper Medical customer service directly. Contact details can typically be found on the manufacturer's official webwebwerf of op die produkverpakking.

Please have your model number (JPD-FR301) and purchase information ready when contacting support.

© 2024 Jumper Medical. All rights reserved.

Hierdie handleiding is onderhewig aan verandering sonder kennisgewing.

Ask a question about this manual