1. Inleiding
This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of the Woods DMMW3 Pocket Digital Multimeter. The DMMW3 is a compact, versatile tool designed for various electrical measurements, featuring 10 test functions suitable for home repairs and general electrical testing.
2. Veiligheidsinligting
WARNING: Read and understand all safety information and operating instructions in this manual before using the Woods DMMW3 Pocket Digital Multimeter. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always inspect the multimeter and test leads for damage before use. Do not use if damaged.
- Maak seker dat die funksieskakelaar in die korrekte posisie is vir die meting wat uitgevoer word.
- Do not exceed the maximum input limits for any function: CAT III 300V, CAT II 600V.
- Wees versigtig wanneer u met voltagbo 30V AC RMS, 42V piek, of 60V DC, aangesien dit 'n skokgevaar inhou.
- Do not operate the meter with the battery cover removed or loosened.
- Vervang die battery onmiddellik wanneer die lae battery-aanwyser verskyn om akkurate lesings te verseker.
- Disconnect test leads from the circuit before changing functions.
- The current input is fused (200mA MAX FUSED). Do not attempt to measure currents exceeding this rating.
3. Pakketinhoud
Verifieer dat alle items teenwoordig en onbeskadig is:
- Woods DMMW3 Pocket Digital Multimeter
- Toetsdrade (Rooi en Swart)
- CR2032 Battery (may be pre-installed or included separately)
- Gebruikershandleiding (hierdie dokument)
4. Produk verbyview
Familiarize yourself with the components of your DMMW3 multimeter:

Figuur 1: Voorkant view of the Woods DMMW3 Pocket Digital Multimeter. The image shows the digital display, function selector dial, and control buttons (MODE, RANGE, HOLD, MAX).
- Digitale skerm: Shows measurement readings, units (DC, AC, nF, µF, V, A, MΩ, kΩ, Hz, %), and indicators (AUTO, HOLD, low battery).
- Function Selector Dial: Rotary switch to select primary measurement functions (mA, Ω/Continuity/Diode/Capacitance, V, Hz%).
- MODUS-knoppie: Toggles between different measurement types within a selected function (e.g., AC/DC voltagbv. weerstand/kontinuïteit/diode/kapasitansie).
- RANGE-knoppie: Manually selects measurement range (if not in auto-ranging mode).
- HOU knoppie: Vries die huidige skermlesing.
- MAX-knoppie: Displays the maximum reading recorded during a measurement session.
- Invoeraansluitings:
- COM (Algemene) Jack: For the black test lead.
- VΩHz%mA Jack: For the red test lead when measuring voltage, resistance, frequency, capacitance, or current (up to 200mA).
5. Opstelling
5.1 Battery installasie
The DMMW3 uses one CR2032 coin cell battery. If the low battery indicator appears on the display, or if the unit does not power on, replace the battery:
- Maak seker dat die multimeter afgeskakel is en ontkoppel alle toetsdrade.
- Vind die batterykompartement aan die agterkant van die eenheid.
- Use a small screwdriver to open the battery compartment cover.
- Remove the old CR2032 battery, noting its polarity.
- Plaas 'n nuwe CR2032-battery met die positiewe (+) kant na bo.
- Plaas die deksel van die batterykompartement terug en maak dit met die skroef vas.
5.2 Verbinding van toetsdrade
Always connect the test leads correctly for accurate and safe measurements:
- Plaas die swart toetsdraad in die COM (Algemene) invoeraansluiting.
- Plaas die rooi toetsdraad in die VΩHz%mA input jack for most measurements (voltage, resistance, continuity, diode, capacitance, frequency, current up to 200mA).
6. Bedryfsinstruksies
6.1 Krag aan/af
To power on the multimeter, rotate the Function Selector Dial from the OFF position to any desired measurement function. To power off, rotate the dial back to the OFF position (indicated by the power symbol ⏻).
6.2 Funksiekeuse
Rotate the Function Selector Dial to choose the primary measurement category:
- mA: For measuring DC or AC current (up to 200mA).
- Ω / Continuity / Diode / Capacitance: For measuring resistance, checking continuity, testing diodes, or measuring capacitance. Use the MODUS button to cycle through these functions.
- V: For measuring DC or AC voltage. Gebruik die MODUS button to switch between DC and AC voltage.
- Hz%: For measuring frequency or duty cycle. Use the MODUS button to switch between frequency (Hz) and duty cycle (%).
6.3 Using Control Buttons
- WYSE: Press to select secondary functions within a dial position (e.g., AC/DC, Resistance/Continuity/Diode/Capacitance, Hz/%).
- RANGE: Press to switch between auto-ranging and manual ranging. In manual ranging, press repeatedly to cycle through available ranges.
- HOU: Druk om die huidige lesing op die skerm te vries. Druk weer om los te laat.
- MAKS: Press to capture and display the maximum value measured during a session. Press again to exit MAX mode.
6.4 Performing Measurements (Examphulle)
Always ensure the circuit is de-energized before connecting test leads for resistance, continuity, diode, or capacitance measurements.
6.4.1 DC/AC Voltage Meting
- Set the Function Selector Dial to V.
- Druk die MODUS button to select DC or AC voltage (DC or AC indicator on display).
- Connect the red test lead to the positive (+) side of the circuit and the black test lead to the negative (-) side or ground.
- Lees die voltage waarde op die skerm.
6.4.2 Weerstandmeting
- Maak seker dat die stroombaan gedeaktiveer is.
- Set the Function Selector Dial to Ω. Druk MODUS until the Ω symbol is displayed.
- Verbind die toetsdrade oor die komponent wat gemeet moet word.
- Lees die weerstandswaarde op die skerm.
6.4.3 Kontinuïteitstoets
- Maak seker dat die stroombaan gedeaktiveer is.
- Set the Function Selector Dial to Ω. Druk MODUS until the continuity symbol (⧸) word vertoon.
- Verbind die toetsdrade oor die stroombaan of komponent.
- A continuous beep indicates continuity (low resistance). The display will show the resistance value.
7. Onderhoud
7.1 Skoonmaak
Vee die omhulsel af met advertensieamp lap en sagte skoonmaakmiddel. Moenie skuurmiddels of oplosmiddels gebruik nie. Hou die invoerterminale vry van vuiligheid en vog.
7.2 Batteryvervanging
Refer to Section 5.1 for detailed battery replacement instructions. Always use a fresh CR2032 battery.
7.3 Sekeringvervanging
The DMMW3 has a 200mA MAX FUSED input for current measurements. If the current measurement function stops working, the fuse may need replacement. This procedure should only be performed by qualified personnel.
- Maak seker dat die multimeter afgeskakel is en ontkoppel alle toetsdrade.
- Open the back casing of the multimeter (this may require removing multiple screws).
- Locate the fuse.
- Replace the blown fuse with a fuse of the exact same type and rating (e.g., 200mA, fast-acting).
- Carefully reassemble the multimeter, ensuring all screws are tightened.
WARNING: Using an incorrect fuse type or rating can damage the meter and pose a serious safety hazard.
7.4 Berging
If the meter is not to be used for an extended period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Probleemoplossing
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| Meter skakel nie aan nie. | Dooie of verkeerd geïnstalleerde battery. | Check battery polarity; replace battery (CR2032). Refer to Section 5.1. |
| Geen lesing of "OL" (Oorlading) word vertoon nie. | Incorrect function selected; open circuit; measurement exceeds range. | Verify function dial setting; check circuit continuity; switch to a higher range if available or use auto-ranging. |
| Onakkurate lesings. | Lae battery; swak toetsdraadverbinding; eksterne interferensie. | Replace battery; ensure secure lead connections; move away from strong electromagnetic fields. |
| Stroommeting werk nie. | Gebreekte lont. | Replace the 200mA fuse. Refer to Section 7.3. |
9. Spesifikasies
| Kenmerk | Detail |
|---|---|
| Modelnommer | DMMW3 |
| Handelsmerk | Southwire (Woods) |
| Meetfunksies | Voltage (AC/DC), Current (DC/AC), Resistance, Continuity, Diode, Capacitance, Frequency, Duty Cycle |
| Veiligheidsgradering | CAT III 300V, CAT II 600V |
| Huidige Inset Sekering | 200mA MAX FUSED |
| Kragbron | 1 x CR2032 Battery |
| Vertoon | Digitale LCD |
| Item gewig | 6.4 onse (ongeveer 181 g) |
| Pakket afmetings | 9 x 5 x 3 duim (ongeveer 22.86 x 12.7 x 7.62 cm) |
| Land van oorsprong | China |
| Datum Eerste Beskikbaar | 27 April 2016 |
10. Waarborg en Ondersteuning
For warranty information or technical support regarding your Woods DMMW3 Pocket Digital Multimeter, please contact Southwire customer service. Retain your proof of purchase for warranty claims.
Manufacturer: Southwire
Kontakbesonderhede kan tipies gevind word op die vervaardiger se amptelike webwebwerf of produkverpakking.