ABB S201-C16

User Manual: ABB S201-C16 Miniature Circuit Breaker

Model: S201-C16 | Brand: ABB

1. Inleiding

This manual provides essential information for the safe and effective installation, operation, and maintenance of the ABB S201-C16 Miniature Circuit Breaker. This device is designed for reliable protection against overcurrent faults in various electrical applications, including commercial appliances and control circuits. Please read this manual thoroughly before installation and use.

2. Veiligheidsinligting

WAARSKUWING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Failure to follow these instructions can result in serious injury or death.

  • Always disconnect power before installing, servicing, or removing the circuit breaker.
  • Maak seker dat alle bedrading voldoen aan plaaslike en nasionale elektriese kodes.
  • Moenie die stroombreker gebruik as dit beskadig lyk nie.
  • Gebruik gepaste persoonlike beskermende toerusting (PPE) wanneer u met elektriese stelsels werk.
  • The device must be installed in an enclosure providing IP20 protection or higher.

3. Produkbeskrywing en -kenmerke

The ABB S201-C16 is a 1-pole miniature circuit breaker from the S200-C series, designed for low voltage applications. It provides thermal/magnetic trip protection against overloads and short circuits.

Sleutel kenmerke:

  • Voltage-gradering: 480Y/277 VAC
  • Ampouderdomsgradering: 16 A
  • Onderbrekingsgradering: 6 kA
  • Aantal pole: 1
  • Tipe reis: Termies/Magneties
  • Montering: DIN-spoor
  • Terminaal tipe: Skroef terminale
  • Omhulselbeskerming: IP20
ABB S201-C16 Miniature Circuit Breaker, front view

Figuur 3.1: Voorkant view of the ABB S201-C16 Miniature Circuit Breaker. This image shows the main body of the circuit breaker, including the toggle switch, ABB branding, model number S201-C16, voltage rating 230/400V, and interrupt capacity 6000. A barcode with the number 4016779464406 is visible on the side.

4. Opstelling en installering

The S201-C16 circuit breaker is designed for DIN-rail mounting. Ensure proper tools and safety procedures are followed during installation.

  1. Kragontkoppeling: Before beginning any installation, ensure that the main power supply to the circuit is completely disconnected and locked out. Verify with a voltage toetser.
  2. Montering: Snap the circuit breaker onto a standard 35mm DIN-rail. Ensure it is securely seated.
  3. Bedrading:
    • Connect the incoming phase conductor to the upper terminal and the outgoing phase conductor to the lower terminal.
    • The circuit breaker accepts wire sizes from 18 - 4 AWG for conductors and 18 - 8 AWG for busbars.
    • Use appropriate screw terminals to secure the wires. Ensure all connections are tight to prevent loose contacts and overheating.
  4. Verifikasie: After wiring, double-check all connections for correctness and tightness.
  5. Kragherstel: Sodra die installasie voltooi en geverifieer is, herstel die krag na die stroombaan.
Kant view of ABB S201-C16 Miniature Circuit Breaker

Figuur 4.1: Kant view of the ABB S201-C16 Miniature Circuit Breaker, showing the DIN-rail mounting mechanism and terminal points. This view highlights the compact design and the screw terminals for wire connections.

5. Bedryfsinstruksies

The ABB S201-C16 Miniature Circuit Breaker operates with a simple toggle mechanism.

  • OP posisie: Push the toggle switch upwards to the 'I' (ON) position to close the circuit and allow current flow.
  • AF posisie: Push the toggle switch downwards to the 'O' (OFF) position to open the circuit and stop current flow.
  • Gestapte Posisie: If an overload or short circuit occurs, the circuit breaker will automatically trip, moving the toggle switch to an intermediate or fully down position (depending on the fault type and specific model behavior). This indicates a fault and protects the circuit.
  • Herstel van 'n uitgeskakelde stroombreker: To reset a tripped breaker, first identify and rectify the cause of the trip (e.g., remove overloaded devices or fix a short circuit). Then, push the toggle switch fully to the 'OFF' position before pushing it back to the 'ON' position. If the breaker trips immediately again, do not attempt to reset it repeatedly; consult a qualified electrician.

6. Onderhoud

Die ABB S201-C16 Miniatuurstroombreker is ontwerp vir minimale onderhoud. Periodieke inspeksie word egter aanbeveel om optimale werkverrigting en veiligheid te verseker.

  • Visuele inspeksie: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. Ensure the toggle switch moves freely.
  • Skoonmaak: If necessary, gently clean the exterior of the circuit breaker with a dry, lint-free cloth. Do not use abrasive cleaners or solvents. Ensure power is disconnected before cleaning.
  • Verbindingskontrole: Annually, or as required by local regulations, verify the tightness of all terminal connections. Loose connections can lead to overheating and potential hazards.
  • Toets: Do not attempt to test the tripping mechanism by intentionally creating a short circuit. Functional testing should only be performed by qualified personnel using appropriate test equipment.

7. Probleemoplossing

ProbleemMoontlike oorsaakOplossing
Stroombreker skakel gereeld af.Oorbelasting op die stroombaan, kortsluiting of foutiewe toestel.Reduce the load on the circuit. Disconnect appliances one by one to identify the faulty one. Check for short circuits in wiring or appliances. If the problem persists, consult an electrician.
Die stroombreker herstel nie.Persistent overload or short circuit, internal damage to the breaker.Ensure the cause of the trip has been resolved. If it still doesn't reset, the breaker may be damaged and needs replacement. Do not force the switch.
Die stroombreker voel warm.Overload, loose connections, or improper wire size.Check for overload. Verify all wire connections are tight. Ensure wire size is appropriate for the current. Disconnect power and consult an electrician immediately.

8. Tegniese spesifikasies

ParameterWaarde
HandelsmerkFIG
ModelnommerS201-C16
TikLae Voltage Miniatuurstroombreker
ReeksS200-C
Voltage Beoordeling480Y/277 VAC
Amperage Gradering16 A
Frekwensiegradering50/60 Hz
Onderbrekingsgradering6 kA
Tipe ReisTermies/Magneties
Reisreeks3 - 5 A Magneties en 1.13 - 1.45 A Termies
Aantal pale1
Aktuator tipeWissel
Draad Grootte18 - 4 AWG-geleier, 18 - 8 AWG-rail
Terminal tipeSkroef
Tipe omhulselIP20
Montage tipeDIN-spoor
Temperatuurgradering-25 tot 55 grade C
Afmetings (H x B x D)88 mm x 17.5 mm x 69 mm
MateriaalInsulation Group II, RAL 7035
Standaarde/GoedkeuringsIEC/EN 60898-1, IEC/EN 60947-2, UL 1077, CSA 22.2
ToepassingEquipment Protection in Commercial Appliances, Protection of Control Circuits Against Overcurrent Faults, Computer Equipment and Other Computer Peripheral Devices
UPC662019168746

9. Waarborg en Ondersteuning

For information regarding product warranty, please refer to the official ABB website or contact your authorized ABB distributor. Technical support can be obtained through ABB's customer service channels.

ABB Contact Information:

  • Webwebwerf: www.abb.com
  • Verwys na die website for regional contact details and support resources.

© 2024 ABB Group. All rights reserved.

Hierdie handleiding is slegs vir inligtingsdoeleindes en is onderhewig aan verandering sonder kennisgewing.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.