Pedrollo PLURIJET M4/80-N

Pedrollo PLURIJET M4/80-N Self-Priming Multi-Stage Water Pump Instruction Manual

Model: PLURIJET M4/80-N | Brand: Pedrollo

1. Inleiding

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo PLURIJET M4/80-N self-priming multi-stage water pump. Please read these instructions carefully before use and retain them for future reference.

The PLURIJET series offers a new, more compact, and robust design. It is recommended for applications requiring a quiet and high-performance self-priming pump.

Pedrollo PLURIJET M4/80-N Self-Priming Multi-Stage Waterpomp

Figure 1: Pedrollo PLURIJET M4/80-N Self-Priming Multi-Stage Water Pump. This image shows the overall design of the pump, highlighting its compact and robust construction.

2. Tegniese Eienskappe

  • Completely renewed range with a new design.
  • Improved hydraulic performance for higher efficiency.
  • Reduced energy consumption.
  • One of the quietest models in the centrifugal pump series.
  • Enhanced priming capabilities.

3. Installasie en gebruik

The PLURIJET pumps are suitable for use with clean water, even when air is present, and with liquids that are not chemically aggressive towards the materials from which the pump is made. Due to their quietness, reliability, and low energy consumption, they are recommended for domestic and civil applications such as water supply systems, pressure boosting, and irrigation.

3.1. Application Limits

  • Liquid temperature: from -10 °C to +40 °C
  • Ambient temperature: up to +40 °C
  • Manometric suction lift: up to 9 m (HS)
  • Maksimum werkdruk: 6 bar
  • Continuous service: S1

4. Opstelling

Proper setup is crucial for optimal performance and longevity of the pump. Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and frost.

4.1. Elektriese aansluiting

Connect the pump to a single-phase 230 V, 50 Hz power supply. Ensure the electrical installation complies with local regulations and safety standards. The power cable is not included and must be appropriately sized for the pump's power requirements (0.55 kW / 0.75 HP).

4.2. Hydraulic Connection

Connect the suction and delivery pipes to the pump's threaded ports. Ensure all connections are watertight to prevent air ingress, which can affect priming and pump performance. Use appropriate sealants and fittings.

4.3. Voorbereiding van die pomp

Before first use, or after any period of disuse, the pump must be primed. Fill the pump body completely with clean water through the dedicated filling port until water overflows. Close the filling port securely before starting the pump.

5. Bedryfsinstruksies

Once installed and primed, the pump is ready for operation. Ensure the suction line is submerged in water and free from obstructions.

5.1. Begin die pomp

Switch on the power supply to the pump. The pump will begin to draw water. Monitor the pressure gauge (if installed) to ensure proper operation. The pump is designed for continuous service (S1).

5.2. Stopping the Pump

To stop the pump, switch off the power supply. For prolonged periods of disuse, especially in freezing conditions, drain the pump completely to prevent damage.

6. Onderhoud

Regular maintenance ensures the longevity and efficient operation of your Pedrollo pump.

6.1. Routine Checks

  • Periodically check for leaks around connections.
  • Ensure the pump is free from excessive vibration or unusual noises.
  • Verify that the ventilation openings on the motor are clear.

6.2. Winterisering

In areas subject to freezing temperatures, drain the pump and associated piping completely to prevent damage from ice expansion. Store the pump in a dry, frost-free location if possible.

7. Probleemoplossing

Hierdie afdeling bied oplossings vir algemene probleme wat u met u pomp kan teëkom.

ProbleemMoontlike oorsaakOplossing
Pomp begin nieNo power supply, motor overload, seized impellerCheck power connection and circuit breaker. Allow motor to cool. Inspect impeller for obstructions.
Pomp loop maar lewer nie water niePump not primed, air leak in suction line, suction lift too high, clogged suction filterRe-prime the pump. Check all suction connections for leaks. Verify suction lift is within limits. Clean suction filter.
Reduced flow or pressurePartial blockage, worn impeller, air in systemCheck for blockages in pipes. Inspect impeller for wear. Bleed air from the system.
Oormatige geraas of vibrasieCavitation, foreign object in pump, worn bearingsEnsure adequate water supply to prevent cavitation. Inspect pump for foreign objects. Contact service for bearing replacement.

8. Spesifikasies

Detailed technical specifications for the Pedrollo PLURIJET M4/80-N pump.

KenmerkendWaarde
ModelPLURIJET M4/80-N
KragtoevoerSingle-phase 230 V, 50 Hz
Krag (kW)0.55 kW
Krag (HP)0.75 HP
Vloeitempo (Q)5 ÷ 80 L/min (up to 4.8 m³/h)
Kop (H)50 ÷ 10 m (max 50m)
Suiging1"
Pomp liggaam materiaalAISI 304 vlekvrye staal
WaaiermateriaalNoryl
Temperatuurbereik vloeistof-10 °C tot +40 °C
OmgewingstemperatuurTot +40 °C
Maks. Werksdruk6 bar
Isolasie klasF
BeskermingIP X4
Vervaardiger Verwysing43PJA5084A1

8.1. Characteristic Curves and Performance Data

Refer to the following graph for detailed performance characteristics (Head vs. Flow Rate) at 50 Hz, n=2900 1/min, HS=0m.

Pedrollo PLURIJET M4/80-N Performance Curves

Figure 2: Characteristic Curves and Performance Data. This graph illustrates the relationship between head (H in meters) and flow rate (Q in L/min or m³/h) for various PLURIJET models, including the M4/80-N.

8.2. Construction Characteristics

Key components and their materials:

  • Pomp liggaam: Stainless steel AISI 304, with threaded ports in compliance with ISO 228/1.
  • Motor Backplate: Stainless steel AISI 304.
  • Impellers: Noryl FE1520PW.
  • Verspreiders: Noryl FE1520PW with anti-wear ring.
  • Motoras: Stainless steel EN 10088-3 - 1.4104.
  • Meganiese seël:
    • Seal Model: AR-13
    • Shaft Diameter: Ø 13 mm
    • Stationary Ring Material: Ceramic
    • Rotational Ring Material: Graphite
    • Elastomer: NBR
  • Laers:
    • PLURIJETm 3/60, 3/80, 3/100, 4/80-N: 6202 ZZ - C3 (6201 ZZ)
    • PLURIJETm 4/100-N: 6203 ZZ (6203 ZZ)
  • Capacitor (Single-phase 230V or 240V):
    • PLURIJETm 3/60-N: 10 µF 450 VL (25 µF 250 V)
    • PLURIJETm 3/80-N: 12.5 µF 450 VL (25 µF 250 V)
    • PLURIJETm 4/80, 3/100-N: 14 µF 450 VL (25 µF 250 V)
    • PLURIJETm 4/100-N: 20 µF 450 VL (60 µF 300 V)
  • Elektriese motor:
    • PLURIJETm: Single-phase 230 V - 50 Hz with thermal overload protector built into the winding.
    • PLURIJET: Three-phase 230/400 V - 50 Hz.
    • Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance.
    • Stator and rotor are made out of magnetic sheet with low iron loss.
    • Insulation: F class.
    • Protection: IP X4.

8.3. Afmetings

Refer to the diagram and table below for the physical dimensions of the pump.

Pedrollo PLURIJET M4/80-N Dimensional Drawing

Figure 3: Dimensional Drawing. This diagram provides a detailed view of the pump's dimensions (in mm), including various measurements labeled 'a', 'b', 'h1', 'h2', 'h3', 'n', 'n1', 'w', 'z', 's'.

ModelHawensAfmetings (mm)
EnkelfaseDrie faseDN1DN2abh1h2h3nn1wz
PLURIJETm 3/60-NPLURIJET 3/60-N1"1"11335718210251183126879
PLURIJETm 3/80-NPLURIJET 3/80-N1"1"11335718210251183126879
PLURIJETm 4/80-NPLURIJET 4/80-N1"1"11335718210251183126879
PLURIJETm 3/100-NPLURIJET 3/100-N1"1"11335718210251183126879
PLURIJETm 4/100-NPLURIJET 4/100-N1"1"13841120210251183126879

Note: The table above includes dimensions for various PLURIJET models. The PLURIJET M4/80-N shares dimensions with other models as indicated.

9. Waarborg en Ondersteuning

For warranty information, please refer to the documentation provided with your purchase or contact your authorized Pedrollo dealer. Keep your proof of purchase for warranty claims.

For technical support, spare parts, or service, please contact your local Pedrollo service center or the retailer from whom you purchased the pump. Provide the model number (PLURIJET M4/80-N) and serial number (if applicable) when seeking assistance.

© 2023 Pedrollo. All rights reserved. Information in this manual is subject to change without notice.

Verwante Dokumente - PLURIJET M4/80-N

Preview Pedrollo PLURIJET 80-100 & 80X-100X Self-Priming Multi-Stage Pompe Datablad
Comprehensive technical specifications, performance data, installation guidance, and construction details for the Pedrollo PLURIJET 80-100 and PLURIJET 80X-100X series of self-priming multi-stage pumps, suitable for domestic and civil applications.
Preview Pedrollo TOP MULTI-TECH & TOP MULTI-EVOTECH Outomatiese Dompelwaterpompe - Gebruikershandleiding
Hierdie dokument verskaf operasionele leiding vir die Pedrollo TOP MULTI-TECH en TOP MULTI-EVOTECH outomatiese dompelbare multi-stage waterpompe. Dit dek algemene inligting, werking, beskerming en tipiese installasie-advies.
Preview Pedrollo TOP MULTI-TECH / TOP MULTI-EVOTECH Automatic Submersible Water Pump Operation Manual
This document provides operational instructions for the Pedrollo TOP MULTI-TECH and TOP MULTI-EVOTECH automatic submersible multi-stage water pumps. It covers general information, operating principles, installation advice, and protection features for optimal performance and longevity.
Preview Pedrollo TOP MULTI-TECH Outomatiese Dompelpompe: Spesifikasies en Werkverrigting
Gedetailleerde tegniese spesifikasies, werkverrigtingskurwes, installasiegids en kenmerke vir die Pedrollo TOP MULTI-TECH-reeks multi-stage outomatiese dompelpompe, ontwerp vir skoonwatertoepassings.
Preview Istruzioni per l'uso: Pompe Elettriche Pedrollo Serie TOP MULTI
Guida completa alle istruzioni per l'uso, l'installazione, la sicurezza e la manutenzione delle pompe elettriche Pedrollo, incluse le serie TOP MULTI, UP, NK e altre.
Preview Marathon M4-reeks wyn- en drankkoeler gebruiks- en versorgingshandleiding
Omvattende gebruikers- en versorgingshandleiding vir Marathon M4-reeks dubbelsone-wyn- en drankkoelers, wat inligting oor veiligheid, installasie, werking, onderhoud en waarborg dek.

Ask a question about this manual