Red Lion 97081001

Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump Instruction Manual

Model: 97081001

1. Inleiding

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Red Lion RL-SWJ100 1 HP Cast Iron Shallow Well Jet Pump. Please read these instructions thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump, red cast iron body with black motor housing.
Figure 1: Red Lion RL-SWJ100 1 HP Shallow Well Jet Pump

2. Veiligheidsinligting

WARNING: Risk of severe injury or death by electrical shock, or damage to the system.

  • Ontkoppel altyd die elektriese krag voordat jy aan die pomp raak.
  • A Ground Fault Circuit Interrupter (GFCI) is required for electrical connections.
  • Indien die kragkabel beskadig is, moet dit slegs deur gekwalifiseerde personeel vervang word.
  • Installation and servicing of this equipment should be performed by technically qualified personnel familiar with the correct selection and use of appropriate tools, equipment, and procedures.
  • Hierdie produk kan jou blootstel aan chemikalieë, insluitend lood, wat in die staat Kalifornië bekend is om kanker en geboortedefekte of ander reproduktiewe skade te veroorsaak. Vir meer inligting, besoek www.P65Warnings.ca.gov.
A person wearing blue work clothes and gloves is handling electrical wires, emphasizing the need for electrical experience.
Figure 2: Electrical experience is required for installation.

3. Produk verbyview

The Red Lion RL-SWJ100 is a 1 HP cast iron shallow well jet pump designed for providing fresh water to rural homes, farms, and cottages. It is suitable for suction lifts down to 25 feet. The pump includes a 30/50 pressure switch and is self-priming after initial prime.

Sleutel kenmerke:

  • Shallow Well Application: Designed for wells less than 25 feet deep.
  • Dubbel Voltage Motor: Heavy-duty 115/230 Volt motor, factory-set for 230 Volts, easily switchable to 115 Volts.
  • Duursame konstruksie: Heavy-duty cast iron casing for longevity. Impeller and volute are made of glass-filled thermoplastic.
  • Integrated Pressure Switch: Includes a 30/50 pressure switch with auto shut-off.
  • Verbindings: 1-1/4-inch Female NPT threaded intake; 1-inch Female NPT threaded discharge.
Diagram showing the internal components and features of the Red Lion RL-SWJ series shallow well jet pump, including motor terminal box, adjustable pressure switch, 1 inch FNPT discharge, 1-1/4 inch FNPT intake, cast iron casing, glass-filled thermoplastic impeller and diffuser, and integrated venturi/nozzle assembly.
Figure 3: RL-SWJ Series Features Diagram

4. Spesifikasies

EienskapWaarde
Modelnommer97081001
Perdekrag (HP)1 HP
Voltage115/230 Volt (Dubbele Volttage)
Amperageer13.2 Amps @ 115V; 6.6 Amps @ 230V
Wattage4800 watt
Maksimum vloeitempo17 Gallonne Per Minuut (GPM)
Maksimum druk74 PSI
Suction/Intake1-1/4-inch Female NPT
Ontslag1-inch Female NPT
MateriaalCast Iron (body), Glass-filled thermoplastic (impeller/volute)
Produkafmetings (L x B x H)9 cm L x 14 cm B x 9.5 cm H
Item gewig28.5 pond
Ingesluit komponente30/50 Pressure Switch, Instruction Manual, Pump
Performance chart for Red Lion RL-SWJ100 shallow well jet pump, showing total dynamic head versus capacity in US GPM at 5 feet of lift for 1/2 HP, 3/4 HP, and 1 HP models.
Figure 4: RL-SWJ100 Performance Chart
Dimensional drawing of the Red Lion RL-SWJ100 shallow well jet pump with height, length, width, and weight specifications.
Figure 5: RL-SWJ100 Dimensions

5. Opstelling en installering

5.1 Vlugtage Keuring

The RL-SWJ100 pump is dual voltage (115/230 Volts) and comes factory-set for 230 Volts. Ensure the pump's voltage setting matches your power source. To change the voltage, remove the cover from the motor terminal box and slide the voltage indicator switch to the desired setting (115V or 230V) using a flat screwdriver.

Diagram illustrating the voltage switch on the Red Lion RL-SWJ series pump, showing positions for 230V and 115V settings.
Figuur 6: Voltage Switch Settings

Video 1: This video demonstrates how to change the voltage setting on a Red Lion RL-SWJ Series Jet Pump from 230V to 115V or vice versa.

5.2 Pressure Tank Installation

If installing with a pressure tank, ensure the tank's pre-charge pressure is set correctly before installation. The pre-charge pressure should be 2 PSI below the pump's cut-in pressure setting (e.g., 28 PSI for a 30 PSI cut-in). Make all pipe connections according to local plumbing codes. Ensure the pipe size from the tank to the house is the same as the pipe size from the pump to the tank.

Video 2: This video provides instructions on how to install or adjust a pressure tank in conjunction with a jet pump system.

6. Bedryfsinstruksies

6.1 Voorbereiding van die pomp

Before starting the pump for the first time or after it has been drained, it must be properly primed. This involves filling the pump casing and suction line with water to ensure it can create the necessary suction to draw water from the well. Refer to the detailed priming instructions in the full owner's manual for your specific setup.

6.2 Aanvanklike aanvang

After priming and ensuring all connections are secure and leak-free, restore power to the pump. The pump should start and build pressure. Monitor the pressure gauge to ensure it reaches the desired cut-off pressure (e.g., 50 PSI for a 30/50 switch). The pump will automatically shut off once the cut-off pressure is reached.

7. Onderhoud

  • Gereelde inspeksie: Periodically check all connections for leaks and ensure the pump is securely mounted.
  • Pressure Tank Check: Verify the pressure tank's air charge annually.
  • Winterisering: In freezing climates, drain the pump and piping completely to prevent damage from ice expansion.
  • Netheid: Keep the pump area clean and free from debris to ensure proper ventilation.

8. Probleemoplossing

This section provides general guidance for common issues. For detailed troubleshooting steps, consult the complete owner's manual.

Algemene kwessies:

  • Pump runs but no water: Check for proper priming, ensure the suction line is submerged, and inspect for air leaks in the suction line.
  • Pomp siklusse te gereeld: This often indicates a problem with the pressure tank (low air charge, waterlogged) or a leak in the system.
  • Pomp begin nie: Verify electrical connections, check the circuit breaker, and ensure the voltage switch is set correctly.
  • Lae druk: Check for clogs in the piping, inspect the impeller for damage, and verify the well's water level.

9. Waarborg en Ondersteuning

9.1 Waarborginligting

The Red Lion RL-SWJ100 pump comes with a 2-year manufacturer's warranty. For specific terms and conditions, please refer to the warranty details provided with your product or contact Red Lion customer support.

9.2 Kliëntediens

For troubleshooting assistance, installation guidance, or to inquire about parts and service, please contact Red Lion customer support. If your product was purchased within 30 days, refer to Amazon's return policy. For purchases beyond 30 days, consult your owner's manual or contact the seller directly if different from Amazon.com.

For additional information, visit the official Red Lion webwebwerf: www.redlionproducts.com