APC Back-UPS BX1400UI User Manual

Model: BX1400UI | Brand: APC

1. Inleiding

The APC Back-UPS BX1400UI is an Uninterruptible Power Supply (UPS) designed to protect your electronic equipment from power outages, surges, and spikes. Featuring Line Interactive Technology and Automatic Voltage Regulation (AVR), this unit provides reliable battery backup and surge protection for connected devices. It includes six IEC 320 C13 outlets, a USB interface for communication, and data line protection.

Voorkant view of the APC Back-UPS BX1400UI Uninterruptible Power Supply, showing the power button and LED indicators.

Figuur 1: Voorkant view of the APC Back-UPS BX1400UI.

2. Belangrike veiligheidsinligting

  • Elektriese gevaar: Hierdie eenheid bevat hoë volumetage components. Do not attempt to open the UPS casing, especially when connected to power. Refer all servicing to qualified personnel.
  • Direkte verbinding: Always connect the UPS directly to a wall outlet. Do not use surge protectors, extension cords, or power strips with the UPS input.
  • Ventilasie: Verseker voldoende ventilasie rondom die UPS. Moenie ventilasie-openinge blokkeer nie.
  • Aanvanklike reuk: A new unit may emit a distinct odor, often described as similar to burnt plastic. This is normal and typically dissipates after a few weeks of continuous operation in a well-ventilated area. It is not indicative of a malfunction.
  • Battery vervanging: User-performed battery replacement during the warranty period will void the product warranty. Refer to the Maintenance section for details.

3. Pakketinhoud

Verifieer dat jou pakket die volgende items bevat:

  • APC Back-UPS BX1400UI Unit
  • Two (2) IEC-C13 to IEC-C14 power cables (for connecting devices to the UPS)
  • Gebruikershandleiding (hierdie dokument)

Let wel: The input power cable (for connecting the UPS to the wall outlet) and the USB communication cable are typically nie ingesluit nie and must be purchased separately if needed.

4. Opstelling

4.1. Unpacking and Battery Connection

  1. Verwyder die UPS versigtig uit sy verpakking.
  2. Locate the yellow battery connector on the rear panel of the UPS. This connector is typically disconnected for safe transport.
  3. Push the yellow battery connector firmly into its socket until it clicks into place. This activates the UPS battery circuits.

4.2. Koppel aan krag

  1. Connect the UPS to a grounded 230V AC wall outlet using an appropriate IEC-320 C14 input power cable (not included).
  2. Ensure the connection is direct to the wall outlet. Do not use surge protectors or extension cords.
  3. Allow the UPS to charge for at least 10 hours before connecting critical equipment to ensure full battery runtime.

4.3. Verbinding van toerusting

The BX1400UI features six IEC 320 C13 outlets for connecting your devices.

  • Battery Backup & Surge Protection Outlets: All six IEC-C13 outlets provide both battery backup and surge protection. Connect your computer, monitor, and other critical electronics to these outlets.
  • Datalynbeskerming: The rear panel includes RJ-11 ports labeled "DSL/Modem/Fax/Phone" for protecting your telephone or DSL line from surges. These ports are not suitable for Ethernet network connections.
  • USB-koppelvlak: Connect a USB Type B cable (not included) from the UPS to your computer for communication and to enable shutdown software functionality.
Rear panel of the APC Back-UPS BX1400UI, showing IEC-C13 outlets, USB port, battery connector, circuit breaker, and data line protection ports.

Figure 2: Rear panel connections of the APC Back-UPS BX1400UI.

5. Bedryfsinstruksies

5.1. Skakel aan/af

  • Om aan te skakel: Press and hold the power button on the front panel until you hear a short beep. The UPS will perform a self-test, and the 'On Line' LED will illuminate green.
  • Om af te skakel: Druk en hou die aan/af-knoppie in totdat die UPS afskakel.

5.2. LED-aanwysers

The front panel features LED indicators to show the UPS status:

  • Aanlyn (Groen LED): Indicates the UPS is operating on utility power and providing power to connected equipment.
  • Op battery (geel LED): Indicates the UPS is operating on battery power during a power outage or brownout. A humming noise is normal during battery operation.
  • Vervang battery (rooi LED): Indicates the battery needs to be replaced.
  • Oorlading (Rooi LED): Indicates that the connected equipment exceeds the UPS's capacity. Disconnect non-essential equipment immediately.

5.3. Outomatiese Voltage Regulasie (AVR)

Die UPS korrigeer outomaties geringe volumetage fluctuations (sags and surges) without switching to battery power, thus preserving battery life. If voltage fluctuations exceed the AVR's correction range, the UPS will switch to battery power.

6. Sleutel kenmerke

  • Line Interactive Technology: Provides stable power by regulating voltage without constantly switching to battery.
  • Outomatiese Voltage Regulasie (AVR): Corrects minor voltage-skommelings sonder om batterykrag te gebruik.
  • Battery-rugsteun: Supplies power to connected equipment during outages.
  • Spanningsbeskerming: Protects connected devices from damaging power surges and spikes.
  • 6 IEC 320 C13 Outlets: Standard outlets for computer equipment.
  • USB-koppelvlak: Enables communication with a computer for monitoring and controlled shutdown.
  • Datalynbeskerming: Safeguards telephone/DSL lines from surges.

7. Sagtewaregebruik

The APC Back-UPS BX1400UI supports USB Human Interface Device (HID) class specifications, allowing it to be recognized by most operating systems without special drivers.

7.1. APC PowerChute Personal Edition (Windows)

For advanced monitoring and management on Windows systems, download the APC PowerChute Personal Edition software from the official APC webwebwerf. Hierdie sagteware laat jou toe om:

  • Monitor UPS status, power consumption, and battery charge.
  • Configure automatic shutdown of your computer during extended power outages.
  • Adjust UPS settings, such as alarm behavior (e.g., disable the beeper during battery operation).
  • Perform self-tests to ensure proper UPS functionality.

7.2. Linux Support (apcupsd / NUT)

For Linux environments, the UPS can be managed using `apcupsd` or Network UPS Tools (NUT). These tools provide similar monitoring and shutdown capabilities. Refer to the documentation for `apcupsd` or NUT for configuration details, typically involving specifying `UPSCABLE usb` and `UPSTYPE usb` for `apcupsd`, or using the `usbhid-ups` driver for NUT.

8. Onderhoud

8.1. Battery vervanging

The APC Back-UPS BX1400UI uses two 12V 7.2Ah sealed lead-acid batteries. The recommended replacement battery pack is APC RBC113.

  • During Warranty: If the unit is still under its 2-year warranty, battery replacement must be performed by Schneider Electric IT (SEIT) customer service. User-performed battery replacement during the warranty period will automatically void the warranty.
  • After Warranty: After the warranty period, batteries can be replaced by the user. However, due to the presence of high voltage components even when disconnected, it is highly recommended that this operation be performed by specialized personnel. If you choose to replace the batteries yourself, exercise extreme caution.
  • Prosedure verbyview (for experienced users only): Disconnect the UPS from all power sources and connected equipment. Disconnect the yellow battery connector. Remove the rear panel screws, then the front panel (which is snap-fitted), and additional screws. Carefully access the battery compartment. Note the orientation and wiring of the existing batteries (taking photos is recommended) to ensure correct installation of the new batteries.

8.2. Circuit Breaker Reset

In case of an overload, the UPS may trip its circuit breaker. To reset, disconnect some equipment from the UPS, then press the circuit breaker button located on the rear panel (refer to Figure 2).

9. Probleemoplossing

ProbleemMoontlike oorsaakOplossing
Die UPS skakel nie aan nie.Battery connector disconnected; No input power.Ensure yellow battery connector is fully inserted. Verify UPS is plugged into a live wall outlet.
Initial strong odor.New unit manufacturing residue.This is normal. Ensure adequate ventilation. Odor will dissipate over time (typically a few weeks).
UPS emits a humming noise.Operating on battery power; Normal electrical noise.Humming is normal when on battery. If persistent and loud on utility power, ensure proper ventilation and check for loose connections.
'Overload' LED is lit.Te veel toerusting gekoppel.Disconnect non-essential equipment. Press the circuit breaker reset button on the rear panel.
'Replace Battery' LED is lit.Battery nader die einde van sy lewensduur.Contact APC support or a qualified technician for battery replacement. Refer to Section 8.1.
Kort batterylooptyd.Battery not fully charged; Battery nearing end of life; Excessive load.Ensure initial 10-hour charge. Reduce connected load. Consider battery replacement if old.

For more detailed troubleshooting, refer to the complete user manual available on the APC webwebwerf.

10. Spesifikasies

KenmerkSpesifikasie
ModelBX1400UI
Kapasiteit (VA/Watt)1400 VA / 700 W
Invoer Voltage230V AC
Invoerfrekwensie50 Hz
Uitset Voltage230V AC (simulated sine wave on battery)
Uitsetpunte6 x IEC 320 C13 (Battery-rugsteun en oorspanningsbeskerming)
Spanningsbeskermingsgradering273 Joule
Battery TipeVerseëlde loodsuur
Batterykonfigurasie2 x 12V 7.2Ah
Tipiese herlaai tyd8 uur (tot 90% kapasiteit)
Runtime (at 700W load)Ongeveer 1 minuut
Runtime (at 100W load)Ongeveer 60 minute
Afmetings (H x B x D)21.5 cm x 13 cm x 33.6 cm
Gewig4.7 kg
interface poorteUSB Type B, RJ-11 (Data Line Protection)
Runtime graph for APC Back-UPS 1400VA, 230V, AVR, IEC Sockets (BX1400UI), showing battery runtime in minutes versus load in watts.

Figure 3: Typical runtime graph for APC Back-UPS 1400VA.

11. Waarborg en Ondersteuning

11.1. Produkwaarborg

The APC Back-UPS BX1400UI comes with a 2-jaar beperkte waarborg vanaf die aankoopdatum. Hierdie waarborg dek defekte in materiaal en vakmanskap onder normale gebruik. Bewaar asseblief u bewys van aankoop vir waarborgeise.

Belangrik: Unauthorized opening of the unit or user-performed battery replacement during the warranty period will void the warranty.

11.2. Tegniese Ondersteuning

For technical assistance, troubleshooting, or warranty service, please contact APC by Schneider Electric customer support. Visit the official APC website for contact information specific to your region, including phone numbers and online support resources.

Online resources often include FAQs, knowledge bases, and downloadable manuals that can provide further assistance.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.