Atago PAL-COFFEE(BX/TDS)

ATAGO PAL-COFFEE(BX/TDS) Digital Handheld Pocket Refractometer User Manual

Inleiding

Die ATAGO PAL-COFFEE(BX/TDS) is a compact, digital handheld refractometer designed for precise measurement of Brix and Total Dissolved Solids (TDS) in coffee. This instrument is essential for baristas and coffee enthusiasts to ensure consistency and quality in their brews. This manual provides comprehensive instructions for the proper use and care of your device.

ATAGO PAL-COFFEE(BX/TDS) Refractometer measuring coffee

Image: The ATAGO PAL-COFFEE(BX/TDS) refractometer shown with a cup of coffee and a spoon, demonstrating its use for coffee measurement.

Opstelling

1. Uitpak

  • Carefully remove the PAL-COFFEE(BX/TDS) refractometer from its packaging.
  • Check for any visible damage. If damaged, contact your supplier immediately.
  • Maak seker dat alle komponente wat op die pakstrokie gelys word, teenwoordig is.

2. Battery Installasie

  • Vind die batteryklepdeksel aan die agterkant van die eenheid.
  • Open the cover and insert two AAA batteries, ensuring correct polarity (+/-).
  • Maak die batterykompartement se deksel stewig toe.

3. Initial Calibration (Zero Setting)

  • Maak seker dat die prisma-oppervlak skoon en droog is.
  • Apply a few drops of clean tap water onto the prism surface.
  • Press the 'ZERO' button. The display should show '0.00%' or '0.00' depending on the mode.
  • Wipe the water off the prism with a soft, clean cloth. The device is now calibrated and ready for use.
ATAGO PAL-COFFEE(BX/TDS) Refractometer on coffee beans

Image: The ATAGO PAL-COFFEE(BX/TDS) refractometer resting on a bed of coffee beans, showcasing the device itself.

Bedryfsinstruksies

1. Sample Voorbereiding

  • Brew your coffee as desired.
  • Allow the coffee to cool to room temperature (ideally between 20-25°C) for accurate readings, or ensure the device's Automatic Temperature Compensation (ATC) is active.
  • Stir the coffee thoroughly to ensure a homogeneous sample.

2. Neem 'n meting

  • Maak seker dat die prisma-oppervlak skoon en droog is.
  • Place 2-3 drops of the prepared coffee sample onto the prism surface. Ensure the entire surface is covered without air bubbles.
  • Close the daylight plate gently over the sample.
  • Press the 'START' button. The measurement will be displayed within a few seconds.
Finger pressing START button on ATAGO PAL-COFFEE(BX/TDS) Refractometer

Image: A finger pressing the 'START' button on the ATAGO PAL-COFFEE(BX/TDS) refractometer, indicating the measurement process.

3. Leesresultate

  • The display will show the Brix (%) or TDS (%) value.
  • To switch between Brix and TDS modes, refer to the device's specific button sequence (usually a long press or multiple presses of a specific button).
  • Record your measurement for consistency tracking.

4. Skoonmaak na gebruik

  • Immediately after each measurement, wipe the sample off the prism and daylight plate with a soft, damp lap.
  • Then, dry the prism surface completely with a clean, dry cloth.
  • Do not use abrasive materials or harsh chemicals, as they can damage the prism.

Onderhoud

1. Cleaning the Prism

  • Regularly clean the prism surface with a soft, lint-free cloth and a small amount of clean water.
  • For stubborn residues, a mild soap solution can be used, followed by thorough rinsing with water and drying.
  • Avoid scratching the prism surface.

2. Berging

  • Store the refractometer in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Keep it in its protective case when not in use to prevent damage.

3. Battery vervanging

  • When the battery indicator on the display shows low power, replace both AAA batteries promptly.
  • Always use new batteries and dispose of old batteries according to local regulations.

Probleemoplossing

ProbleemOplossing
Onakkurate lesingsEnsure the prism is clean. Re-perform zero calibration with clean water. Ensure the sample temperature is stable.
Display shows 'Err'This usually indicates a measurement error. Check if the prism is clean, if enough sample is applied, or if the sample is outside the measurement range. Re-calibrate if necessary.
Toestel skakel nie aan nieCheck if batteries are inserted correctly. Replace with new batteries.
Slow response or flickering displayBatterye is dalk laag. Vervang batterye.

Spesifikasies

KenmerkWaarde
HandelsmerkAtago
ModelPAL-COFFEE(BX/TDS)
Produk afmetings6 x 4 x 11 cm
Item gewig180 gram
ASINB00LTH2PUG

Waarborg en Ondersteuning

For warranty information, please refer to the documentation provided with your purchase or contact your authorized Atago dealer. For technical support or service, please reach out to the manufacturer's customer service department or your local distributor. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.