Seco-Larm E-37EV

Seco-Larm E-37EV Alarm Pager System

Model: E-37EV

Inleiding

The Seco-Larm E-37EV Alarm Pager System is designed to monitor up to three zones for premises or vehicles, providing alerts via a portable receiver. This system features a 4W output transmitter for extended range and a belt-clip receiver with code-learning capabilities. It is compatible with various alarm control panels and communication systems.

Kenmerke

  • Monitors up to three zones per premises or vehicle, including manual paging.
  • Transmitter can page an unlimited number of receivers.
  • Up to ½-mile range in ideal conditions.
  • Connects to nearly any type of burglar alarm control panel, vehicle alarm, or communication panel.
  • One positive and two negative instant trigger inputs.
  • Automatic power antenna control.
  • Connects to a CB antenna, car AM radio antenna (cable included), or optional external antenna (E-37ANT).
  • Over two million possible coding combinations.
  • Belt-clip receiver included.
  • Code-learning receiver learns up to three transmitters.
  • Color LEDs on the receiver indicate triggered zone (Green, Orange, or Red).
  • Audible or vibration page indicator.
  • EEPROM memory stores codes for up to one year without power.
  • Stores the last six pages for easy recall.
  • Unattended page indicator.
  • Lae battery aanwyser.
Seco-Larm E-37EV Alarm Pager System Features List

Image: Features list on the product packaging for the Seco-Larm E-37EV Alarm Pager System.

Pakketinhoud

Verifieer dat alle komponente in die pakket teenwoordig is:

  • 1 Sender
  • 1 Vibrating Receiver (Batteries not included)
  • 1 Radio Antenna Adapter Cord (18")
Seco-Larm E-37EV Alarm Pager System Box Front

Image: Front of the Seco-Larm E-37EV Alarm Pager System box, showing the transmitter, receiver, and kit contents.

Opstelling

Sender Installasie

  1. Kragverbinding: Connect the transmitter to a 12VDC power source. Ensure proper polarity.
  2. Antenna verbinding: Connect the provided radio antenna adapter cord to the transmitter. For optimal range, consider connecting to a CB antenna, car AM radio antenna, or the optional E-37ANT external antenna. Ensure the antenna body is properly grounded for best performance.
  3. Sneller-insette: Connect the alarm system's trigger outputs to the transmitter's one positive and two negative instant trigger inputs. Refer to your alarm system's manual for specific wiring instructions.

Ontvanger Opstelling

  1. Battery installasie: The receiver requires two AAA batteries (not included). Open the battery compartment and insert the batteries, observing correct polarity.
  2. Kode leer: The receiver is designed to learn up to three transmitter codes. Follow the specific instructions provided with the product for the code-learning procedure. This typically involves activating the transmitter while the receiver is in a learning mode.
  3. Moduskeuse: Select between audible or vibration page indication using the switch on the receiver.

Operasie

Manual Paging

The system supports manual paging. Consult the specific product documentation for instructions on how to initiate a manual page from the transmitter, if applicable.

Sone-aanduiding

When an alarm is triggered, the receiver's color LEDs will illuminate to indicate which zone was activated:

  • Groen LED: Indicates Zone 1 trigger.
  • Oranje LED: Indicates Zone 2 trigger.
  • Rooi LED: Indicates Zone 3 trigger.

Page Recall

The receiver stores the last six pages received. Use the recall function (refer to receiver buttons) to review vorige waarskuwings.

Unattended Page Indicator

If a page is received and not acknowledged, the receiver will provide an unattended page indication (e.g., a flashing LED or repeated alert) until it is cleared.

Lae battery aanwyser

The receiver features a low battery indicator to alert you when the AAA batteries need replacement.

Onderhoud

Battery vervanging

When the low battery indicator activates on the receiver, replace the two AAA batteries promptly. Ensure correct polarity during installation.

Skoonmaak

Clean the units with a soft, dry cloth. Avoid using abrasive cleaners or solvents, which may damage the casing of interne komponente.

Probleemoplossing

ProbleemMoontlike oorsaakOplossing
No page receivedReceiver batteries low or deadVervang ontvangerbatterye.
No page receivedTransmitter not poweredCheck 12VDC power connection to the transmitter.
No page receivedTransmitter not triggeredVerify alarm system trigger output is connected correctly and functioning.
Verminderde reeksPoor antenna connection or groundingEnsure antenna is securely connected and properly grounded. Avoid obstructions.
Receiver not responding to transmitterReceiver not coded to transmitterPerform the code-learning procedure for the receiver.

Spesifikasies

KenmerkSenderOntvanger
Number of CodesOver 2 million factory pre-setUp to 3 transmitter codes
Krag12VDC3VDC (2 AAA-batterye)
RF-uitsetkrag4W maksimumNVT
Huidige dreineringStandby: 10mA, Active: 1AStandby: 1mA, Active: 50mA
Frekwensie27 MHz27 MHz
Antenna impedansie50ΩNVT
ReeksUp to ½ mile1Up to ½ mile1
Afmetings4⅛"x3⅛"x1⅝" (105x79x33mm)3"x2⅛"x⅝" (76x54x16mm)
Gewig5.1 oz (145 g)1.6-oz (45g) (without battery)
Battery Life (Receiver)NVTOngeveer. 1 maand2

1Actual range may vary depending on the environment, installation, and/or antenna.

2Based on 5 transmissions/day.

Seco-Larm E-37EV Alarm Pager System Specifications

Image: Back of the Seco-Larm E-37EV Alarm Pager System box, detailing transmitter and receiver specifications.

Waarborg inligting

This Seco-Larm E-37EV Alarm Pager System comes with a 1 jaar waarborg from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For warranty claims or service, please contact Seco-Larm customer support.

Ondersteuning

For further assistance, technical support, or to inquire about optional accessories such as the E-37RV extra vibrating receiver or E-37ANT external antenna, please refer to the official Seco-Larm website or contact their customer service department. Always ensure to follow local regulations and safety guidelines during installation and operation.