1. Inleiding
The White-Rodgers 8A18Z-2 is an evaporative cooling control panel designed to manage single-stage evaporative cooling systems. This control panel is intended for use in conjunction with the White-Rodgers 1F51N-619 thermostat. It features an integral transformer for 120 VAC or 240 VAC to 24 VAC operation, separate fan and pump relays, and options for high or low fan speed selection. Its lightweight, weather-resistant plastic case meets relevant code requirements.
2. Veiligheidsinligting
WAARSKUWING: Installation and servicing of this control panel must be performed by a qualified technician. Disconnect all power to the unit before installing or servicing to prevent electrical shock or equipment damage.
- Always follow local electrical codes and ordinances.
- Ensure proper grounding of the control panel.
- Do not operate the unit with damaged wiring.
- Hou kinders weg van elektriese komponente.
- This control panel is designed for evaporative cooling applications only.
3. Pakketinhoud
Verifieer dat alle komponente teenwoordig is voordat u met die installasie begin:
- White-Rodgers 8A18Z-2 Evaporative Cooling Control Panel
- Installasie-instruksies (hierdie handleiding)
- Note: The White-Rodgers 1F51N-619 thermostat, required for operation, is sold separately.
4. Opstelling en installering
The 8A18Z-2 control panel is designed for wall mounting. Ensure the mounting location is protected from direct weather exposure and allows for proper ventilation.
4.1 Monteer die beheerpaneel
- Select a suitable wall location near the evaporative cooler unit and a power source.
- Maak die beheerpaneeldeksel oop.
- Secure the control panel to the wall using appropriate fasteners through the designated mounting holes.
4.2 Bedradingsinstruksies
The relay panel is removable for easier field wiring. Refer to the wiring diagram provided inside the control panel cover for specific connections. Ensure all connections are secure and comply with local electrical codes.
- Kragtoevoer: Connect the 120 VAC or 240 VAC power supply to the integral transformer terminals as indicated.
- Termostaat verbinding: Connect the White-Rodgers 1F51N-619 thermostat to the low voltage terminals (24 VAC) on the control panel.
- Waaierverbindings: Connect the evaporative cooler fan motor wires to the fan relay terminals. Select either high or low fan speed as desired.
- Pompverbindings: Connect the evaporative cooler pump motor wires to the pump relay terminals.

Figure 1: White-Rodgers 8A18Z-2 Evaporative Cooling Control Panel. This image shows the compact, grey plastic enclosure of the control panel, designed for wall mounting and housing the internal relays and transformer for evaporative cooler operation.
5. Bedryfsinstruksies
Once properly installed and wired, the 8A18Z-2 control panel operates in conjunction with the connected 1F51N-619 non-programmable thermostat.
- Krag aan: After installation, restore power to the control panel.
- Termostaatbeheer: Use the connected 1F51N-619 thermostat to set the desired temperature and operating mode (e.g., Cool, Fan Only).
- Keuse van waaierspoed: The control panel allows for selection between high and low fan speeds. This setting is typically configured during installation via wiring connections or jumpers on the relay board. Consult the wiring diagram for details.
- Evaporative Cooling Cycle: When the thermostat calls for cooling, the control panel will activate the pump to saturate the cooler pads and then activate the fan to circulate cooled air.
6. Onderhoud
The White-Rodgers 8A18Z-2 control panel requires minimal maintenance. Regular inspection is recommended to ensure optimal performance.
- Jaarlikse inspeksie: Annually, or before the cooling season, inspect the control panel for any signs of wear, damage, or loose connections.
- Skoonmaak: Keep the exterior of the control panel clean and free of dust and debris. Use a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Bedradingskontrole: Periodically check all wiring connections to ensure they are tight and free from corrosion.
7. Probleemoplossing
Before troubleshooting, ensure all power to the unit is disconnected.
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| No power to control panel or thermostat |
|
|
| Waaier werk nie |
|
|
| Pomp werk nie |
|
|
If problems persist after attempting these solutions, contact a qualified HVAC technician.
8. Spesifikasies
| Model | 8A18Z-2 |
| Tik | Evaporative Cooling Control Panel |
| Verenigbaarheid | Designed for use with White-Rodgers 1F51N-619 thermostat |
| Invoer Voltage | 120 VAC of 240 VAC |
| Uitset Voltage (Thermostat) | 24 VAC |
| Combined Relay Loads (Full Load) | 16.0 A @ 120 VAC, 8.0 A @ 240 VAC |
| Combined Relay Loads (Locked Rotor) | 96.0 A @ 120 VAC, 48.0 A @ 240 VAC |
| Fan Relay (Full Load) | 12.0 A @ 120 VAC, 6.0 A @ 240 VAC |
| Fan Relay (Locked Rotor) | 72.0 A @ 120 VAC, 36.0 A @ 240 VAC |
| Pump Relay (Full Load) | 10.0 A @ 120 VAC, 5.0 A @ 240 VAC |
| Pump Relay (Locked Rotor) | 60.0 A @ 120 VAC, 30.0 A @ 240 VAC |
| Materiaal | Weather-resistant plastic case |
| Kleur | Grys |
| Montage tipe | Muurmontering |
| Item gewig | 8 pond (ongeveer 3.6 kg) |
9. Waarborg en Ondersteuning
For warranty information and technical support, please contact White-Rodgers customer service or visit their official webwerf. Hou jou aankoopkwitansie vir waarborgeise.
White-Rodgers Contact Information:
- Webwebwerf: www.emerson.com/en-us/automation/commercial-residential-solutions/white-rodgers