1. Inleiding
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Vortice Record Extractor Fan M10/4T 100mm with Timer. This unit is designed for intermittent or continuous ventilation in small to medium domestic or commercial premises, such as bathrooms, utility rooms, or kitchens. Please read these instructions thoroughly before installation and use, and retain them for future reference.

Figuur 1: Voorkant view of the Vortice Record Extractor Fan M10/4T 100mm with Timer. This image displays the fan's white casing and central circular grille.
2. Veiligheidsinligting
WAARSKUWING: Om die risiko van brand, elektriese skok of besering van persone te verminder, let op die volgende:
- Installation must be carried out by a qualified electrician in accordance with all local and national wiring regulations.
- Ontkoppel altyd die kragtoevoer voordat u enige installasie, onderhoud of skoonmaak uitvoer.
- Hierdie toestel is nie bedoel vir gebruik deur persone (insluitend kinders) met verminderde fisiese, sensoriese of geestelike vermoëns, of 'n gebrek aan ervaring en kennis nie, tensy hulle toesig of instruksies oor die gebruik van die toestel gegee is deur 'n persoon wat verantwoordelik is vir hul veiligheid.
- Kinders moet onder toesig wees om te verseker dat hulle nie met die toestel speel nie.
- Moenie hierdie waaier met 'n vaste toestand-snelheidsbeheertoestel gebruik nie.
- Ensure that the air discharge is not obstructed.
- The fan must not be installed in areas where the ambient temperature exceeds 40°C (104°F).
3. Pakketinhoud
Carefully unpack the product and check for any damage. If any components are missing or damaged, contact your retailer immediately.
- Vortice Record Extractor Fan M10/4T unit
- Instruksie Handleiding
- Monteringshardeware (skroewe, muurproppe)
- Power cord (may not be included depending on regional regulations or specific model variant)
4. Spesifikasies
The following table outlines the key technical specifications for the Vortice Record Extractor Fan M10/4T 100mm with Timer.
| Kenmerk | Spesifikasie |
|---|---|
| Handelsmerk | Draaikolk |
| Model Naam | M10/4T (11630) |
| Elektriese waaierontwerp | Uitlaatwaaier |
| Kragbron | Elektriese kabel |
| Voltage | 240 Volt |
| Wattage | 16 Watt |
| Lugvloeikapasiteit | 85 Cubic Meters Per Hour (approx. 50 CFM) |
| Geraasvlak | 39 Desibel |
| Bladlengte | 100 millimeter |
| Item gewig | 0.43 kilogram (ongeveer 15.1 onse) |
| Pakket afmetings | 18.4 L x 7.6 H x 13.0 W (centimeters) / 7.6 x 5.39 x 3.23 (inches) |
| Installasie tipe | Muurmontering |
| Soort kamer | Badkamer |
| Spesiale kenmerk | Timer funksie |
| Beheer metode | Touch (likely referring to external switch) |
| Voltooi Tipe | Metaal |
| Sertifisering | CE Goedgekeur |

Figuur 2: Technical data and energy label for the Vortice Record Extractor Fan. Key data points include a maximum flow rate of 82 m³/h, total electrical power consumption of 14.3 W at maximum flow, and a sound power level (LWA) of 51 dB(A).
5. Installasie
Installation should only be performed by a qualified professional to ensure compliance with electrical safety standards and optimal performance.
5.1. Die keuse van 'n ligging
Select a suitable wall-mount location, typically in a bathroom or utility area, ensuring adequate space for the fan and ducting. Avoid locations directly above heat sources or where the fan might be exposed to direct water spray.

Figuur 3: Example of a Vortice extractor fan installed on a wall in a room, demonstrating typical placement for ventilation.
5.2. Montering en bedrading
- Berei die opening voor: Create an appropriate opening in the wall for the fan's ducting, typically 100mm in diameter. Refer to the dimensional drawing for precise measurements.
- Bevestig die waaier: Mount the fan unit securely to the wall using the provided mounting hardware. Ensure it is level and stable.
- Elektriese verbinding: Connect the fan to the main electrical supply. The M10/4T model includes a timer function, which requires specific wiring to a switched live and permanent live supply. Consult the wiring diagram provided with the product packaging or a qualified electrician for correct connection.
- Leiding: Connect appropriate ducting to the fan's outlet to direct extracted air outdoors. Ensure all connections are sealed to prevent air leakage.

Figuur 4: Technical drawing illustrating the dimensions of the Vortice Extractor Fan, including overall width (A), height (B), depth (C), and duct diameter (E, F).
6. Operasie
The Vortice Record Extractor Fan M10/4T is designed for simple operation, typically controlled via an external light switch or a dedicated fan switch.
6.1. Basic On/Off
When connected to a light switch, the fan will activate when the light is turned on. When connected to a dedicated fan switch, simply toggle the switch to turn the fan on or off.
6.2. Tydfunksie
The M10/4T model features an adjustable timer. After the fan is switched off (e.g., by turning off the light), the fan will continue to operate for a preset duration before automatically shutting down. This duration can typically be adjusted using a small potentiometer located within the fan unit (access usually requires removing the front cover and disconnecting power). Experiment with the timer setting to achieve the desired run-on time for effective ventilation.
7. Onderhoud
Regular maintenance ensures optimal performance and longevity of your extractor fan. Always disconnect the power supply before any maintenance.
7.1. Skoonmaak van die buitekant
Vee die buitekant van die waaier af met 'n sagte, damp lap. Moenie skuurmiddels, oplosmiddels of harde chemikalieë gebruik nie, aangesien dit die afwerking kan beskadig.
7.2. Cleaning the Fan Blades
Periodically, dust and debris may accumulate on the fan blades, reducing efficiency. To clean:
- Ontkoppel krag: Ensure the fan's power supply is completely disconnected at the circuit breaker.
- Verwyder deksel: Carefully remove the front grille or cover of the fan.
- Skoon lemme: Gently clean the fan blades and surrounding areas with a soft brush or a vacuum cleaner with a brush attachment. Avoid bending the blades.
- Hermonteer: Once clean, reattach the cover securely.

Figuur 5: Intern view of the Vortice Extractor Fan, showing the fan blades and motor housing, which may require periodic cleaning.
8. Probleemoplossing
If you encounter issues with your Vortice Extractor Fan, refer to the following common problems and solutions:
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| Waaier skakel nie aan nie | Geen kragtoevoer Foutiewe bedrading Interne fout | Check circuit breaker and wall switch. Ensure correct wiring (consult electrician). If problem persists, contact support. |
| Fan is excessively noisy | Los montering Obstruksie in waaierblaaie Motor kwessie | Ensure fan is securely mounted. Disconnect power and check for obstructions. If noise persists, contact support. |
| Onvoldoende lugonttrekking | Blocked ducting Vuil waaierblaaie Incorrect fan size for room | Check ducting for blockages. Clean fan blades as per maintenance section. Ensure fan is appropriately sized for the room volume. |
| Timer not working correctly | Verkeerde timerinstelling Bedradingskwessie | Adjust the timer potentiometer. Verify timer wiring with an electrician. |
For issues not listed here or if solutions do not resolve the problem, please contact qualified technical support.
9. Waarborg en Ondersteuning
9.1. Waarborginligting
Please refer to the warranty card or documentation included with your purchase for specific warranty terms and conditions. Keep your proof of purchase for any warranty claims.
9.2. Kliëntediens
For technical assistance, spare parts, or service, please contact your retailer or visit the official Vortice webwebwerf vir ondersteuning kontak inligting.