Intermatic UWZ48E-240U

Intermatic UWZ48E-240U Hour Meter Instruction Manual

Model: UWZ48E-240U

1. Inleiding

This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic UWZ48E-240U Hour Meter. This device is designed to accurately record operating hours for various electrical equipment. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

2. Veiligheidsinligting

WAARSKUWING: Risk of electric shock. Installation and servicing should be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse box before installing or servicing the unit.

  • Volg altyd plaaslike elektriese kodes en regulasies.
  • Ensure the power supply matches the meter's voltage rating (240V AC, 60Hz).
  • Do not operate the meter if it appears damaged.
  • Hou kinders weg van elektriese installasies.

3. Produk verbyview

The Intermatic UWZ48E-240U is a flush-mount hour meter designed for precise time tracking. It features a clear display for accumulated hours and offers both quick connect and screw terminals for versatile wiring options.

Intermatic UWZ48E-240U Hour Meter with dimensions

Figuur 1: Voorkant view of the Intermatic UWZ48E-240U Hour Meter. The image shows the meter's face with the Intermatic logo, a six-digit hour display, and electrical ratings (UWZ 48-L, 110-127V~ 60Hz). Please note that while the image displays 110-127V, the product model UWZ48E-240U is rated for 240V AC, 60Hz as per specifications. Dimensions of 1.79 inches by 1.79 inches are indicated on the sides.

3.1 Sleutelkenmerke:

  • Flush mount design with retaining bracket.
  • Combo quick connect and screw terminals.
  • 240V AC, 60Hz operation.
  • Duursame plastiekkonstruksie.
  • Compact dimensions: 1.79"W x 1.79"H.

4. Installasie

4.1 Montering

  1. Maak seker dat krag by die bron ontkoppel is.
  2. Create a panel cutout of 1.79" x 1.79" (45.5 x 45.5 mm). The panel thickness can be up to 0.35" (9 mm).
  3. Insert the hour meter into the cutout from the front of the panel.
  4. Secure the unit in position using the provided plastic slip-on retaining bracket from the rear of the panel.
  5. Opsioneel: For 72 mm square or round openings, an optional 72 mm bezel can be used (not included).

4.2 Bedrading

The UWZ48E-240U features combo quick connect and screw terminals. Connect the meter in parallel with the load or circuit you wish to monitor. Ensure correct voltage (240V AC, 60Hz) is supplied to the meter terminals.

  • Vinnige verbinding: Use appropriate spade connectors for a secure connection.
  • Skroefterminale: Strip wire insulation to the recommended length, insert into the terminal, and tighten the screw firmly.

Nadat die bedrading aangebring is, maak seker dat alle verbindings stewig en geïsoleer is voordat die krag herstel word.

5. Operasie

The Intermatic UWZ48E-240U Hour Meter operates automatically when power is supplied to its terminals. The mechanical display will increment, showing the total accumulated operating hours. The meter does not have a reset function, providing a continuous record of equipment usage.

  • The display shows hours in a six-digit format, typically with the last digit representing tenths of an hour.
  • No user interaction is required for operation once installed and powered.

6. Onderhoud

The UWZ48E-240U Hour Meter is designed for maintenance-free operation. However, periodic inspection is recommended to ensure optimal performance.

  • Skoonmaak: If necessary, gently wipe the display window with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Inspeksie: Periodically check wiring connections for tightness and ensure the meter is securely mounted.
  • Omgewingstoestande: Ensure the operating environment remains within the specified temperature range (up to 160°F / 71°C).

7. Probleemoplossing

ProbleemMoontlike oorsaakOplossing
Meter display is blank or not incrementing.No power to the meter, incorrect wiring, or meter malfunction.
  • Verify power supply to the circuit.
  • Kontroleer alle bedradingsverbindings vir korrekte polariteit en styfheid.
  • Verseker die voltage matches the meter's rating (240V AC).
  • If power and wiring are correct, the meter may require replacement.
Inaccurate hour readings.Intermittent power supply or meter malfunction.
  • Ensure a stable power supply to the monitored equipment.
  • If issues persist, the meter may require replacement.

8. Spesifikasies

ModelUWZ48E-240U
HandelsmerkIntermaties
Voltage240 Volt
Frekwensie60 Hz
Huidige gradering1 Amps
Connector TipeSpade, Screw Terminals
Montage tipeFlush Mount (Wall Mount)
MateriaalPlastiek
KleurWit
Produk Afmetings (B x H)1.79" x 1.79" (45.5 x 45.5 mm)
Paneeluitsny1.79" x 1.79" (45.5 x 45.5 mm)
Max Panel Thickness0.35" (9 mm)
Boonste temperatuurgradering160 grade Fahrenheit (71 grade Celsius)
SertifiseringsCSA
Item gewig0.2 pond

9. Waarborg en Ondersteuning

For warranty information and technical support, please refer to the official Intermatic webwebwerf of kontak hul kliëntediensafdeling. Bewaar u aankoopbewys as bewys van aankoop.

Jy kan besoek die Intermatic Winkel op Amazon vir meer produkinligting.

© 2023 Intermatic. All rights reserved. Information subject to change without notice.

Ask a question about this manual