VOLTCRAFT PPS-11360

VOLTCRAFT PPS-11360 Adjustable Laboratory Power Supply User Manual

Model: PPS-11360

1. Produk verbyview

The VOLTCRAFT PPS-11360 is a versatile and programmable laboratory power supply designed for various electronic applications. It provides a stable and adjustable DC output, making it suitable for development, testing, and educational purposes. Key features include a wide voltage and current range, USB connectivity for remote control, and multiple output channels.

Voorkant view of the Voltcraft PPS-11360 power supply

Beeld 1.1: Voorkant view of the VOLTCRAFT PPS-11360 Adjustable Laboratory Power Supply, showing the display and control knobs.

Sleutel kenmerke:

  • Verstelbare Uitset Voltage: 1 V/DC to 36 V/DC
  • Adjustable Output Current: 0 A to 5 A
  • Total Power Output: 180 W
  • Aantal uitsette: 2
  • USB Programmable for remote control
  • Robuuste metaal casing

2. Veiligheidsinstruksies

Please read these safety instructions carefully before operating the device to prevent injury or damage. Keep this manual for future reference.

  • Elektriese veiligheid: Always connect the power supply to a grounded outlet. Do not operate the device with wet hands or in damp environments. Ensure the power cord is undamaged.
  • Ventilasie: Ensure adequate ventilation around the unit. Do not block the ventilation openings. Overheating can lead to device malfunction or damage.
  • Bedryfsomgewing: Use the device in a clean, dry environment, away from direct sunlight, extreme temperatures, and corrosive gases.
  • Diens: Moenie probeer om die toestel self oop te maak of te herstel nie. Verwys alle diens na gekwalifiseerde personeel.
  • Uitvoerverbindings: Ensure correct polarity when connecting loads to the output terminals. Avoid short circuits.

3. Opstelling

3.1 Uitpak en inspeksie

Carefully remove the power supply from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. If any damage is found, contact your supplier immediately.

3.2 Pakketinhoud

  • VOLTCRAFT PPS-11360 Laboratory Power Supply
  • AC kragkabel
  • Gebruikershandleiding

3.3 Koppel aan krag

  1. Maak seker dat die kragskakelaar op die voorpaneel in die AF-posisie is.
  2. Connect the provided AC power cord to the power input socket on the rear panel of the power supply.
  3. Plug the other end of the AC power cord into a suitable grounded electrical outlet (100-240V AC, 50/60Hz).
Agter view of the Voltcraft PPS-11360 power supply

Image 3.1: Rear panel of the VOLTCRAFT PPS-11360, showing the power input, fan, USB port, and remote control connector.

3.4 Connecting a Load

  1. Ensure the power supply is turned OFF before connecting any load.
  2. Connect the positive (+) terminal of your load to the red output terminal (MAIN OUTPUT +) on the front panel.
  3. Connect the negative (-) terminal of your load to the black output terminal (MAIN OUTPUT -) on the front panel.
  4. For remote control, connect the USB cable to the USB port on the rear panel and to your computer. Install necessary drivers and software as per the manufacturer's webwebwerf.

4. Bedryfsinstruksies

4.1 Aan-/afskakel

To power on the device, flip the power switch on the front panel to the ON position. The display will illuminate. To power off, flip the switch to the OFF position.

4.2 Aanpassing van volumetage en huidige

  1. Draai die voltage adjustment knob to set the desired output voltage. The display will show the set voltage.
  2. Turn the current adjustment knob to set the desired output current limit. The display will show the set current limit.
  3. Connect your load. The display will show the actual output voltage and current being delivered to the load.

4.3 Using Preset Modes (P1, P2, P3)

The device features preset memory functions (P1, P2, P3) to store and recall frequently used voltage and current settings. Use the "MODE" switch to select between Normal, Preset, and Remote Control modes. In Preset mode, use the "RECALL" button to cycle through and select P1, P2, or P3.

4.4 Remote Control Operation (USB)

For remote control via USB, ensure the USB cable is connected to both the power supply and your computer. Set the "MODE" switch to "Remote Ctrl". Use the provided software (available from VOLTCRAFT website) to control voltage, current, and other parameters from your computer. Refer to the software manual for detailed instructions.

5. Onderhoud

5.1 Skoonmaak

To clean the exterior of the power supply, use a soft, dry cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the casing and display. Ensure the device is powered off and unplugged before cleaning.

5.2 Ventilasie

Regularly check that the ventilation openings on the rear panel are free from dust and obstructions. A clogged fan or vents can lead to overheating and reduced performance. Use compressed air to gently clear any dust buildup.

5.3 Sekeringvervanging

If the power supply does not turn on, check the fuse located near the AC input on the rear panel. To replace the fuse:

  1. Disconnect the power cord from the wall outlet and the power supply.
  2. Use a small flat-head screwdriver to open the fuse holder.
  3. Remove the old fuse and replace it with a new fuse of the same type and rating (T6AL 250V).
  4. Close the fuse holder securely.

Waarskuwing: Always use a fuse with the specified rating to prevent damage to the unit or fire hazard.

6. Probleemoplossing

ProbleemMoontlike oorsaakOplossing
No power/Unit does not turn onPower cord not connected; Power outlet faulty; Blown fuseCheck power cord connection; Test power outlet; Replace fuse (see Section 5.3)
Geen uitset voltage/huidigeOutput terminals not connected correctly; Output voltage/current set to zero; Overload protection activatedVerify load connections; Adjust voltage/current settings; Reduce load or check for short circuit
Eenheid oorverhitBlocked ventilation; Excessive ambient temperature; Prolonged operation at maximum loadClear ventilation openings; Ensure adequate airflow; Reduce load or operating time
USB remote control not workingIncorrect MODE setting; USB cable faulty; Driver not installed; Software issueSet MODE to "Remote Ctrl"; Try a different USB cable; Install correct drivers; Consult software manual or VOLTCRAFT support

7. Spesifikasies

ParameterWaarde
ModelnommerPPS-11360
Uitset Voltage1 - 36 V/DC
Uitsetstroom0 - 5 A
Uitset krag180 W
Aantal uitsette2
Invoer Voltage100-240V AC, 50/60Hz
Afmetings (L x B x H)20.8 x 20 x 8 cm
Gewig2.4 kg
MateriaalMetaal
Connector TipeUSB
VeiligheidsnakomingCE

8. Waarborg en Ondersteuning

VOLTCRAFT products are designed for reliability and precision. This product comes with a standard warranty period. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official VOLTCRAFT webwebwerf.

For technical support, troubleshooting assistance, or spare parts availability, please contact VOLTCRAFT customer service. You can find contact information on the VOLTCRAFT webwebwerf of in jou produkdokumentasie.

Beskikbaarheid van onderdele: 1 Year (as per product specifications).

VOLTCRAFT brand logo

Image 8.1: VOLTCRAFT brand logo.

© 2023 VOLTCRAFT. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.