Inleiding
This manual provides essential information for the safe and efficient operation of your Peavey IPR 2 5000 Power Amplifier. Please read these instructions thoroughly before operating the unit to ensure proper setup, optimal performance, and to prevent damage.
Belangrike veiligheidsinligting
WAARSKUWING: RISIKO VAN ELEKTRIESE SKOK. MOET NIE OOPMAAK NIE.
WAARSKUWING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Do not place objects filled with liquids, such as vases, on this apparatus. This device must be mounted in a rack only. Installer should refer to the mounting instructions.
Always ensure proper grounding and ventilation. Do not block ventilation openings. Refer all servicing to qualified service personnel.
Opstel en verbindings
The Peavey IPR 2 5000 is designed for rack mounting. Ensure adequate space for ventilation around the unit.
Agterpaneel oorview

Invoerverbindings
Die amplifier features balanced XLR and 1/4" (6.3mm) inputs for each channel (Channel A and Channel B).
- XLR-penkonfigurasie: Pin 1 (Sleeve), Pin 2 (Tip), Pin 3 (Ring).
- 1/4" (6.3mm) Jack Configuration: Sleeve, Tip, Ring.
- A THRU/OUT and B THRU/OUT: These jacks allow you to send the input signal from Channel A or B to another amplifier or device.
Uitset verbindings
Speaker outputs are provided for Channel A and Channel B. These are Speakon-type connectors.
- Luidsprekeruitsette: Each channel supports 800 Watts/40V RMS at a minimum impedance of 2 Ohms.
- Speldkonfigurasie: 1+ Positive, 1- Negative.
Crossover skakelaars
Each channel has a three-position switch for crossover settings:
- HI PASS: Engages a high-pass filter, suitable for driving mid-high frequency speakers.
- VOLLE REIK: Bypasses the crossover, sending the full audio spectrum to the output.
- SUBWOOFER: Engages a low-pass filter, ideal for driving subwoofers.
Kragverbinding
Koppel die amplifier to a standard 120V~, 60Hz, 400 Watts AC power source using the provided power cable. Ensure the power source can supply sufficient current (e.g., a dedicated 20 amp circuit for high output).
- breker: The unit includes a resettable circuit breaker for protection.
Bedryfsinstruksies
Before powering on, ensure all connections are secure and correct. Start with volume controls at their minimum setting.
- Krag aan: Press the power button on the front panel. The unit will perform a self-test.
- Insetsein: Apply your audio input signal to the XLR or 1/4" inputs.
- Volume aanpassing: Slowly increase the volume controls for Channel A and Channel B to the desired listening level.
- Moniteringsaanwysers: Observe the front panel indicators for signal presence, DDT (Distortion Detection Technique) activation, temperature, and DC protection.
DDT Protection
The Peavey IPR 2 5000 features DDT (Distortion Detection Technique) protection, which prevents amplifier clipping and speaker damage by dynamically limiting the output signal when distortion is detected. This ensures clear sound even under high demand.
Onderhoud
Gereelde onderhoud verseker die lang lewensduur en optimale prestasie van u amplewendiger.
- Skoonmaak: Gebruik 'n sagte, droë lap om die buitekant skoon te maak. Moenie vloeibare skoonmaakmiddels of oplosmiddels gebruik nie.
- Ventilasie: Ensure that the ventilation grilles and fan are free from dust and obstructions. Periodically clean the fan area with compressed air if necessary.
- Kabelverbindings: Periodically check all input and output cable connections for tightness and wear.
Probleemoplossing
As jy probleme ondervind met jou ampVerwys na die volgende algemene probleme en oplossings vir die lifer:
| Probleem | Moontlike oorsaak | Oplossing |
|---|---|---|
| Geen krag nie | Power cable disconnected, circuit breaker tripped, power outlet fault. | Check power cable, reset circuit breaker, test power outlet. |
| Geen klankuitset nie | Input cables disconnected, speaker cables disconnected, volume too low, incorrect crossover setting, DDT active. | Verify all cable connections, increase volume, check crossover switch, ensure input signal is present. If DDT is active, reduce input level. |
| Verwronge klank | Input signal too high, speaker impedance too low, DDT engaged. | Reduce input signal level, ensure speaker impedance meets specifications (2 Ohms minimum), check speaker wiring. |
| Overheating / Fan noise | Blocked ventilation, excessive load, dust accumulation. | Ensure clear airflow around the unit. Reduce load if possible. Clean fan and vents. |
Indien die probleem voortduur nadat u hierdie oplossings probeer het, kontak gekwalifiseerde dienspersoneel.
Spesifikasies
| Kenmerk | Detail |
|---|---|
| Model | IPR25000 |
| Handelsmerk | Peavey |
| Kraguitset (per kanaal) | 800 Watts/40V RMS (2 Ohms Min) |
| Aantal kanale | 2 |
| Invoerverbindings | XLR, 1/4" (6.3mm) |
| Uitset Connectors | Speakon-type |
| Crossover-instellings | Hi Pass, Full Range, Subwoofer |
| Kragverbruik | 120V~, 60Hz, 400 Watts |
| Afmetings (L x B x H) | 19 x 4 x 4 duim |
| GTIN (UPC) | 014367153422 |
Waarborg en Ondersteuning
The Peavey IPR 2 5000 Power Ampverligter kom met 'n 1 jaar waarborg. For warranty claims or technical support, please contact Peavey Electronics directly or refer to their official webwebwerf.
Vervaardiger: Peavey Electronics