Inleiding
This manual provides detailed instructions for the proper use and maintenance of your My Weigh Triton T2 Digital Pocket Scale. Designed for precision and durability, this scale offers accurate measurements for various applications. Please read this manual thoroughly before operating the device.
Veiligheidsmaatreëls en Gebruiksriglyne
- Do Not Exceed Capacity: Never exceed the maximum capacity of 120 grams for the Triton T2 scale at any time. Overloading can damage the weighing mechanism.
- Stabiele oppervlak: Always place the scale on a flat, stable surface. Ensure the scale is not exposed to vibrations, air currents, extreme temperatures, or dust, as these can affect accuracy.
- Akklimatisering: When turning the scale on, allow it to self-test and acclimate. The display will typically show '0.0' when ready.
- Expansion Tray: The protective cover is removable when fully open and can be used as an expansion tray for weighing larger items.
- Stabiele lesings: The display may show slight fluctuations due to the extreme sensitivity of the scale. The correct reading is achieved when the readout becomes stable.
Opstelling
Battery installasie
The My Weigh Triton T2 scale requires 2 AAA batteries, which are included. To install or replace batteries, locate the battery compartment on the underside of the scale, open the cover, insert the batteries according to the polarity indicators, and close the compartment securely.
Aanvanklike Plasing
Place the scale on a firm, level, and stable surface, away from drafts, vibrations, and extreme temperature changes. This ensures optimal performance and accuracy.
Bedryfsinstruksies
Krag aan/af
- To turn the scale ON, druk die AAN/AF button (red button). The display will show '88888' then '0.0' or '0.00'.
- To turn the scale AF, druk en hou die AAN/AF knoppie totdat die skerm afskakel.
Weeg prosedure
- Turn the scale on and wait for it to stabilize at '0.0'.
- Gently place the item to be weighed onto the center of the weighing platform.
- Lees die stabiele gewig wat op die LCD-skerm vertoon word.
Eenheid Omskakeling
The Triton T2 scale can display weight in multiple units. To change the weighing unit:
- Met die skaal aan, druk die EENHEID button repeatedly to cycle through available units: Grams (g), Ounces (oz), Troy Ounces (ozt), and Pennyweight (dwt).
- The selected unit will be indicated on the display.
Tara Funksie
The Tare function allows you to subtract the weight of a container, so you only measure the contents.
- Place an empty container on the weighing platform.
- Druk die tarra button (often labeled '-0-' or 'T'). The display will reset to '0.0'.
- Voeg die items wat geweeg moet word in die houer. Die skerm sal slegs die netto gewig van die items wys.
Using the Expansion Tray
The scale's protective cover can be detached and inverted to serve as an expansion tray, providing a larger surface for weighing items. Simply open the cover fully, detach it, and place it upside down on the weighing platform.
Kalibrasie
Calibration ensures the accuracy of your scale. A 100g calibration weight (not included) is required for this procedure.
- Turn the scale AF and place it on a flat, stable surface.
- Druk en hou die EENHEID druk en laat dan die AAN/AF button. The display will show the required calibration weight (e.g., '120.0g').
- Druk die EENHEID button again. The display will read 'CAL' and then '0.0'.
- Gently place the specified calibration weight (e.g., 100g or 120g, depending on the scale's prompt) onto the center of the weighing platform and wait for approximately 3 seconds.
- Druk die EENHEID button. The display should show 'PASS' and then return to '0.0'. Calibration is now complete. Remove the weight.
Onderhoud
- Skoonmaak: Maak die skaal skoon met 'n sagte, damp lap. Moenie skuurmiddels gebruik of die skaal in water dompel nie.
- Berging: Store the scale in a dry, cool place. Avoid storing it in areas with high humidity or extreme temperatures.
- Batterysorg: Verwyder batterye as die skaal nie vir 'n lang tydperk gebruik gaan word om lekkasie te voorkom.
Probleemoplossing
- Onstabiele lesings: If readings are unstable, ensure the scale is on a flat, stable surface, away from drafts, vibrations, and electronic devices that may cause interference. Recalibration may also be necessary.
- Display Errors: If the display shows 'EEEE' or 'O-Ld', the scale is overloaded. Remove the weight immediately. If 'Lo' appears, batteries are low and need replacement.
Spesifikasies
- Handelsmerk: My Weeg
- Model: Triton T2
- Kapasiteit: 120 gram
- Akkuraatheid: 0.1 gram
- Weegeenhede: Grams (g), Ounces (oz), Troy Ounces (ozt), Pennyweight (dwt)
- Vertoon: Verligte LCD
- Krag: 2 x AAA-batterye (ingesluit)
- Materiaal: Akrielnitril Butadieen Styreen (ABS)
- Kenmerke: Tare function, Auto Calibration, Overload Protection, Expansion Tray (cover)
- Item gewig: Ongeveer 6.4 onse
Produk verbyview

Waarborg en Ondersteuning
The My Weigh Triton T2 Digital Pocket Scale comes with a Lifetime Replacement Warranty (CE certified). For warranty claims or technical support, please contact My Weigh customer service through their official website or authorized distributors. Keep your purchase receipt as proof of purchase.