Dickson TM320

Dickson TM320 Temperature and Humidity Data Logger

Instruksie Handleiding

1. Inleiding

The Dickson TM320 is a versatile data logger designed to accurately monitor and record temperature and humidity levels. Featuring a large display for real-time readings, audio/visual alarms, and convenient data transfer options via USB and flash card, it provides essential environmental monitoring for various applications. Its user-friendly design ensures ease of use and reliable performance.

  • USB Enabled Download: Easily transfer recorded data to a computer.
  • Flash Memory Data Transfer Capability: Utilize flash cards for convenient data retrieval.
  • Jumbo Display: Clear and easy-to-read real-time measurements.
  • Maklik om te gebruik: Intuitive interface for straightforward operation.

2. Veiligheidsinligting

Please read all safety instructions before operating the device. Failure to do so may result in damage to the device or personal injury.

  • Moenie die toestel blootstel aan uiterste temperature buite die gespesifiseerde bedryfsbereik nie.
  • Avoid direct contact with water or high humidity environments beyond the non-condensing range.
  • Gebruik slegs gespesifiseerde kragbronne en bykomstighede.
  • Moenie probeer om die toestel self oop te maak of te herstel nie. Verwys alle diens na gekwalifiseerde personeel.
  • Hou buite bereik van kinders.

3. Pakketinhoud

Verifieer dat alle items in die pakket teenwoordig is:

  • Dickson TM320 Data Logger
  • Instructiehandleiding (hierdie dokument)
  • USB-kabel (kan afsonderlik verkoop word)
  • SD Card (may be sold separately)
  • Batteries (may be pre-installed or included)

4. Produk verbyview

Voorkant view of Dickson TM320 Data Logger with display showing '0.0' and battery indicator.

Figuur 4.1: Voorkant View. Shows the large digital display, 'DICKSON' branding, and three control buttons: MIN/MAX, ALARM, and SAVE.

Kant view of Dickson TM320 Data Logger showing USB port, sensor input, and ventilation slots.

Figuur 4.2: Kant View met Hawens. Illustrates the mini-USB port for data transfer and external sensor input jacks, along with ventilation for internal sensors.

Terug view of Dickson TM320 Data Logger showing battery compartment and mounting holes.

Figuur 4.3: Terug View. Displays the battery compartment cover and keyhole slots for wall mounting.

Top view of Dickson TM320 Data Logger showing the SD card slot.

Figuur 4.4: Bo View. Shows the slot for inserting an SD card for data storage and transfer.

5. Opstelling

5.1. Battery Installasie

  1. Vind die batterykompartement aan die agterkant van die toestel (verwys na Figuur 4.3).
  2. Skuif die batterydeksel oop.
  3. Insert the required batteries (typically AA or AAA, check compartment for type) ensuring correct polarity (+/-).
  4. Maak die batterydeksel stewig toe.

5.2. Aanvanklike Aanskakeling

The device should power on automatically once batteries are installed. The display will illuminate, showing current readings or a startup sequence.

5.3. Monteer die toestel

The TM320 can be placed on a flat surface or mounted on a wall:

  • Oppervlakte plasing: Ensure the device is placed on a stable, level surface away from direct heat sources or extreme drafts.
  • Muurmontering: Use appropriate screws (not included) with the keyhole slots on the back of the device (refer to Figure 4.3) to secure it to a wall. Ensure it is mounted in a location representative of the environment you wish to monitor.

6. Operasie

6.1. Verstaan ​​die skerm

The jumbo display provides real-time information:

  • Huidige leeswerk: Shows the live temperature or humidity value.
  • Eenhede: Indicates Fahrenheit (F) or Celsius (C) for temperature, and %RH for humidity.
  • Battery aanwyser: Wys die oorblywende batterylewe.
  • CH (kanaal): Indicates which channel is currently displayed (e.g., CH 1 for temperature, CH 2 for humidity).

6.2. Knoppie Funksies

  • MIN/MAX-knoppie: Press to cycle through minimum, maximum, and current readings for both temperature and humidity. Hold to reset min/max values.
  • ALARM-knoppie: Druk om view current alarm settings. Hold to enter alarm setting mode (refer to section 6.4).
  • STAAR-knoppie: Press to manually save a data point.

6.3. Data logging

The TM320 automatically logs data at a pre-set interval. Data can be viewed on the display or downloaded to a computer.

6.4. Stel alarms in

The device features audio/visual alarms for out-of-range conditions.

  1. Druk en hou die ALARM button until the alarm setting mode is activated.
  2. Gebruik die MIN / MAX button to navigate between temperature and humidity alarm settings (high/low).
  3. Gebruik die SPAAR button to adjust the alarm threshold values.
  4. Druk ALARM weer om te bevestig en die instellingsmodus te verlaat.

6.5. Data Download (USB)

  1. Connect the TM320 to your computer using a compatible USB cable (refer to Figure 4.2 for port location).
  2. The device should be recognized as a removable storage device or require specific Dickson software (refer to manufacturer's website for software).
  3. Follow the software instructions to download and analyze the logged data.

6.6. Data Transfer (Flash Card)

If your model supports flash card data recovery:

  1. Insert a compatible SD card into the SD card slot (refer to Figure 4.4).
  2. The device may automatically transfer data or require a specific button press (consult software/manual for details).
  3. Remove the SD card and insert it into a computer's card reader to access the data.

7. Onderhoud

7.1. Skoonmaak

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the sensor vents or ports.

7.2. Battery vervanging

Replace batteries when the low battery indicator appears on the display. Follow the battery installation steps in Section 5.1.

7.3. Berging

When not in use for extended periods, remove the batteries and store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Probleemoplossing

ProbleemMoontlike oorsaakOplossing
Toestel skakel nie aan nie.Dooie of verkeerd geïnstalleerde batterye.Kontroleer batterypolariteit; vervang met vars batterye.
No data is being logged.Device not powered on; memory full; logging paused.Ensure device is on; download data to clear memory; check software settings for logging status.
Display shows 'Err' or abnormal readings.Sensor malfunction; out of range conditions.Move device to a stable environment; contact support if error persists.
Cannot download data via USB.Incorrect cable; driver issue; software not installed.Ensure correct USB cable; install necessary drivers/software from Dickson webwebwerf.
Alarm klink nie.Alarm disabled; volume too low; thresholds set incorrectly.Check alarm settings (Section 6.4); ensure alarm is enabled and thresholds are appropriate.

9. Spesifikasies

KenmerkDetail
ModelnommerTM320
Temperatuurreeks-4 tot 158°F (-20 tot 70°C)
Humiditeitsbereik0-95% RH (nie-kondenserend)
VervaardigerDickson Unigage Inc.
Produk afmetings19.56 x 16.51 x 8.89 cm (7.7 x 6.5 x 3.5 duim)
Produk Gewig385.55 g (0.85 lbs)
Data-oordragUSB, Flash Card (SD)
VertoonJumbo LCD

10. Waarborg en Ondersteuning

This product is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Dickson website. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Dickson customer service through their official channels.

Dickson Official Webwebwerf: www.dicksonlogger.com

© 2024 Dickson. All rights reserved.

Ask a question about this manual