Lithonia Lighting SB 432 120 1/4 GESB

Lithonia Lighting SB 432 120 1/4 GESB Fluorescent Wraparound Fixture Instruction Manual

Model: SB 432 120 1/4 GESB

1. Produk verbyview

The Lithonia Lighting SB 432 120 1/4 GESB is a 4-foot, 4-light, 32-watt T8 fluorescent wraparound fixture designed for residential or light commercial applications. It features an electronic ballast and an acrylic prismatic lens. This fixture provides broad light distribution suitable for offices, schools, and corridors, and is UL Listed for damp liggings.

Lithonia Lighting Square-Basket Fluorescent Wraparound Fixture

Beeld 1: verbyview of the Lithonia Lighting Square-Basket Fluorescent Wraparound Fixture.

2. Veiligheidsinligting

Read all instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or other hazards.

  • WAARSKUWING: Risiko van elektriese skok. Ontkoppel krag by die lont of stroombreker voor installering of diens.
  • Installasie moet deur 'n gekwalifiseerde elektrisiën uitgevoer word in ooreenstemming met alle nasionale en plaaslike elektriese kodes.
  • Verseker die toevoer voltage is 120 Volts AC.
  • Moenie naby brandbare materiale installeer nie.
  • Hierdie toebehore is geskik vir damp locations but not for direct water exposure.
  • Moenie probeer om die toebehore te wysig nie.
  • This fixture is not designed for dimming applications.

3. Produkkenmerke

  • Prismatic Lens: Linear side prisms control brightness, and pyramidal bottom prisms minimize lamp image for uniform light distribution.
  • Maklike toegang: Full end cap factory installed with a hinged diffuser that opens from either side for convenient cleaning and re-lamping.
  • Elektroniese ballas: Equipped with one 32W electronic ballast for efficient operation.
  • Montage Veelsydigheid: Designed for surface or stem mounting, allowing for individual or row installation.
  • Sertifiserings: UL Listed (standard), suitable for damp locations. Optional CSA or cUL, Mexico NOM.
Diagram showing mounting options and light distribution of the fixture

Image 2: Illustration of mounting options and light distribution capabilities.

4. Pakketinhoud

Die pakket sluit in:

  • 1 x Lithonia Lighting SB 432 120 1/4 GESB Fluorescent Wraparound Fixture

Let wel: Fluorescent T8 bulbs (32-watt) and installation hardware (screws, wire nuts, etc.) are nie ingesluit nie en moet apart gekoop word.

5. Opstelling en installering

Before beginning installation, ensure power is disconnected at the circuit breaker. This fixture is designed for surface or stem mounting.

  1. Berei monteringsplek voor: Identify the desired mounting location on the ceiling or wall. Mark the positions for mounting screws. Ensure the location can support the fixture's weight (approximately 12 pounds).
  2. Boorgate: Drill appropriate pilot holes for your mounting hardware. If replacing an existing fixture, align the new fixture with existing holes if possible, or create new ones.
  3. Veilige toebehore: Mount the fixture securely to the surface using appropriate screws and anchors (not included).
  4. Bedrading: Connect the fixture's electrical wires to the building's supply wires.
    • Connect the white wire from the fixture to the white (neutral) wire from the supply.
    • Connect the black wire from the fixture to the black (hot) wire from the supply.
    • Connect the green or bare copper ground wire from the fixture to the ground wire from the supply.
    Use UL-listed wire nuts (not included) to secure all connections. Ensure all connections are tight and properly insulated.
  5. Install T8 Bulbs: Open the hinged diffuser. Insert four 32-watt T8 fluorescent bulbs into the lamp holders. Ensure bulbs are seated correctly.
  6. Maak die verspreider toe: Close the hinged diffuser, ensuring it latches securely on both sides.
  7. Herstel krag: Sodra die installasie voltooi is en alle verbindings veilig is, herstel die krag by die stroombreker.
Lithonia Lighting SB 432 120 1/4 GESB fixture with diffuser removed, showing internal components and lamp houers

Beeld 3: Intern view of the fixture, illustrating bulb installation area.

6. Operasie

To operate the fixture, simply turn on the wall switch connected to the fixture's power supply. The electronic ballast provides instant-on functionality for the T8 fluorescent lamps.

  • This fixture is designed for 120 Volt AC operation.
  • Do not use with dimmer switches, as this fixture is not designed for dimming applications.

7. Onderhoud

Regular maintenance ensures optimal performance and longevity of your fixture.

  • Skoonmaak: Disconnect power before cleaning. The hinged diffuser can be opened from either side for easy access. Clean the acrylic lens and metal housing with a soft, damp lap. Vermy skuur skoonmakers.
  • Gloeilamp vervanging: Disconnect power before replacing bulbs. Open the hinged diffuser. Carefully remove old T8 bulbs and insert new 32-watt T8 fluorescent bulbs. Ensure they are properly seated in the lamp holders. Close the diffuser securely.
  • Inspeksie: Periodically inspect wiring and connections for any signs of wear or damage.

8. Probleemoplossing

If the fixture does not operate correctly, refer to the following troubleshooting guide:

ProbleemMoontlike oorsaakOplossing
Die armatuur lig nie op nie.Geen krag aan die armatuur nie.
Foutiewe gloeilampe.
Faulty ballast.
Los bedrading konneksie.
Kontroleer die stroombreker en muurskakelaar.
Replace bulbs with new 32W T8 fluorescent bulbs.
Contact a qualified electrician to inspect/replace the ballast.
Ontkoppel die krag en kontroleer alle draadverbindings.
Lights flicker or hum.Old or incompatible bulbs.
Ballastprobleem.
Lae voltage.
Replace bulbs. Ensure they are 32W T8.
Contact a qualified electrician to inspect/replace the ballast.
Consult an electrician to check supply voltage.
Fixture emits a slight electrical tingle when touched.Onbehoorlike aarding.Immediately disconnect power. Have a qualified electrician inspect the grounding connection and overall wiring to ensure safety.

If problems persist after attempting these solutions, contact a qualified electrician or Lithonia Lighting customer support.

9. Spesifikasies

KenmerkDetail
HandelsmerkLithonia Beligting
ModelnommerSB 432 120 1/4 GESB
Afmetings (L x B x H)13.75 cm L x 48 cm B x 2.88 cm H
Gewig12 pond
Voltage120 Volt
Wattage32 watts (per bulb, 4 bulbs total)
LigbronFluorescent (T8)
Aantal ligbronne4
MateriaalAcrylic (lens), Metal (housing)
Voltooi TipeWit
Montage tipeSurface, Suspended (Stem Mount)
SertifiseringsUL-gelys, geskik vir damp liggings
Ballas tipeElektronies
Helderheid11200 Lumen (total)

10. Waarborg en Ondersteuning

Waarborg: This Lithonia Lighting fixture comes with a 1-year warranty on parts from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

Kliëntediens: For technical assistance, warranty claims, or replacement parts, please contact Lithonia Lighting customer service. Refer to the official Lithonia Lighting webwebwerf vir huidige kontakinligting.

Jy kan besoek die Lithonia-beligtingswinkel op Amazon vir meer produkinligting.

© 2024 Lithonia Lighting. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.